Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area Formula

Fx Copy
LaTeX Copy
Distance Between Flange and Web is the measured distance from the outer face of the flange to the web toe of its fillet if the section is in rolled shape. Check FAQs
K=(Pbf-(AcsFyst)Fyctwc)-tf5
K - Distance Between Flange and Web?Pbf - Computed Force?Acs - Cross Sectional Plate Area?Fyst - Stiffener Yield Stress?Fyc - Column Yield Stress?twc - Column Web Thickness?tf - Flange Thickness?

Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area Example

With values
With units
Only example

Here is how the Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area equation looks like with Values.

Here is how the Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area equation looks like with Units.

Here is how the Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area equation looks like.

5Edit=(5000Edit-(20Edit50Edit)50Edit2Edit)-15Edit5
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Design of Steel Structures » fx Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area

Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area Solution

Follow our step by step solution on how to calculate Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area?

FIRST Step Consider the formula
K=(Pbf-(AcsFyst)Fyctwc)-tf5
Next Step Substitute values of Variables
K=(5000kN-(2050MPa)50MPa2mm)-15mm5
Next Step Prepare to Evaluate
K=(5000-(2050)502)-155
Next Step Evaluate
K=0.005m
LAST Step Convert to Output's Unit
K=5mm

Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area Formula Elements

Variables
Distance Between Flange and Web
Distance Between Flange and Web is the measured distance from the outer face of the flange to the web toe of its fillet if the section is in rolled shape.
Symbol: K
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Computed Force
Computed Force delivered by the flange of a moment connection plate multiplied by 5/3 (dead and live loads only) and 4/3 (live and dead loads in conjunction with wind & earthquake forces).
Symbol: Pbf
Measurement: ForceUnit: kN
Note: Value should be greater than 0.
Cross Sectional Plate Area
Cross Sectional Plate Area is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
Symbol: Acs
Measurement: AreaUnit:
Note: Value should be greater than 0.
Stiffener Yield Stress
Stiffener Yield Stress is the minimum stress at which a stiffener will undergo permanent deformation or plastic flow without a significant increase in load.
Symbol: Fyst
Measurement: PressureUnit: MPa
Note: Value should be greater than 0.
Column Yield Stress
Column Yield Stress is the minimum stress at which a column will undergo permanent deformation or plastic flow without a significant increase in load.
Symbol: Fyc
Measurement: PressureUnit: MPa
Note: Value should be greater than 0.
Column Web Thickness
Column Web Thickness is the smallest dimension measured perpendicular to height of column web.
Symbol: twc
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Flange Thickness
The Flange Thickness is the thickness of a flange in a protruded ridge, lip or rim, either external or internal of a beam such as an I-beam or a T-beam.
Symbol: tf
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other formulas in Design of Stiffeners under Loads category

​Go Column-Web Depth Clear of Fillets
dc=4100twc3FycPbf
​Go Thickness of Column Web given Column Web Depth Clear of Fillets
twc=(dcPbf4100Fyc)13

How to Evaluate Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area?

Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area evaluator uses Distance Between Flange and Web = (((Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Yield Stress*Column Web Thickness))-Flange Thickness)/5 to evaluate the Distance Between Flange and Web, The Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area formula is defined as the distance between the outer face of the column flange and the web toe of its fillet. Distance Between Flange and Web is denoted by K symbol.

How to evaluate Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area using this online evaluator? To use this online evaluator for Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area, enter Computed Force (Pbf), Cross Sectional Plate Area (Acs), Stiffener Yield Stress (Fyst), Column Yield Stress (Fyc), Column Web Thickness (twc) & Flange Thickness (tf) and hit the calculate button.

FAQs on Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area

What is the formula to find Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area?
The formula of Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area is expressed as Distance Between Flange and Web = (((Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Yield Stress*Column Web Thickness))-Flange Thickness)/5. Here is an example- 5700 = (((5000000-(20*50000000))/(50000000*0.002))-0.015)/5.
How to calculate Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area?
With Computed Force (Pbf), Cross Sectional Plate Area (Acs), Stiffener Yield Stress (Fyst), Column Yield Stress (Fyc), Column Web Thickness (twc) & Flange Thickness (tf) we can find Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area using the formula - Distance Between Flange and Web = (((Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Yield Stress*Column Web Thickness))-Flange Thickness)/5.
Can the Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area be negative?
No, the Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area, measured in Length cannot be negative.
Which unit is used to measure Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area?
Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area can be measured.
Copied!