Distance between Infiltration Gallery and Source given Discharge Formula

Fx Copy
LaTeX Copy
The Distance Between IG and Source refers to the distance between the infiltration gallery and the source point. Check FAQs
L=k((H)2-(Ho)2)2Q
L - Distance Between IG and Source?k - Coefficient of Permeability?H - Height of Saturated Zone?Ho - Depth of Water in Infiltration Gallery?Q - Discharge?

Distance between Infiltration Gallery and Source given Discharge Example

With values
With units
Only example

Here is how the Distance between Infiltration Gallery and Source given Discharge equation looks like with Values.

Here is how the Distance between Infiltration Gallery and Source given Discharge equation looks like with Units.

Here is how the Distance between Infiltration Gallery and Source given Discharge equation looks like.

9.9855Edit=10Edit((17.55Edit)2-(10.31Edit)2)21.01Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Distance between Infiltration Gallery and Source given Discharge

Distance between Infiltration Gallery and Source given Discharge Solution

Follow our step by step solution on how to calculate Distance between Infiltration Gallery and Source given Discharge?

FIRST Step Consider the formula
L=k((H)2-(Ho)2)2Q
Next Step Substitute values of Variables
L=10cm/s((17.55m)2-(10.31m)2)21.01m³/s
Next Step Convert Units
L=0.1m/s((17.55m)2-(10.31m)2)21.01m³/s
Next Step Prepare to Evaluate
L=0.1((17.55)2-(10.31)2)21.01
Next Step Evaluate
L=9.98546534653465m
LAST Step Rounding Answer
L=9.9855m

Distance between Infiltration Gallery and Source given Discharge Formula Elements

Variables
Distance Between IG and Source
The Distance Between IG and Source refers to the distance between the infiltration gallery and the source point.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Coefficient of Permeability
The Coefficient of Permeability refers to the soil characteristics describes how easily a liquid will move through the soil.
Symbol: k
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Height of Saturated Zone
The Height of saturated Zone refers to the height of the ground level at the infiltration gallery which is considered at some distance from the source.
Symbol: H
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Depth of Water in Infiltration Gallery
The Depth of Water in Infiltration Gallery refers to the depth of water which is considered inside the infiltration gallery.
Symbol: Ho
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge
The Discharge refers to the volume of fluid passing through a cross-sectional area of a stream or pipe per unit time.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.

Other formulas in Flow into Infiltration Gallery category

​Go Discharge Passing through Vertical Section of Infiltration Gallery
Q=k((H)2-(Ho)2)2L
​Go Coefficient of Permeability given Discharge
k=Q(H)2-(Ho)22L
​Go Height of Saturated Zone given Discharge
H=(2QLk)+(Ho)2
​Go Depth of Water in Gallery given Discharge
Ho=(H)2-(2QLk)

How to Evaluate Distance between Infiltration Gallery and Source given Discharge?

Distance between Infiltration Gallery and Source given Discharge evaluator uses Distance Between IG and Source = (Coefficient of Permeability*((Height of Saturated Zone)^2-(Depth of Water in Infiltration Gallery)^2))/(2*Discharge) to evaluate the Distance Between IG and Source, The Distance between Infiltration Gallery and Source given Discharge is defined as the value of distance between infiltration gallery and source when we have prior information of other parameters used. Distance Between IG and Source is denoted by L symbol.

How to evaluate Distance between Infiltration Gallery and Source given Discharge using this online evaluator? To use this online evaluator for Distance between Infiltration Gallery and Source given Discharge, enter Coefficient of Permeability (k), Height of Saturated Zone (H), Depth of Water in Infiltration Gallery (Ho) & Discharge (Q) and hit the calculate button.

FAQs on Distance between Infiltration Gallery and Source given Discharge

What is the formula to find Distance between Infiltration Gallery and Source given Discharge?
The formula of Distance between Infiltration Gallery and Source given Discharge is expressed as Distance Between IG and Source = (Coefficient of Permeability*((Height of Saturated Zone)^2-(Depth of Water in Infiltration Gallery)^2))/(2*Discharge). Here is an example- 9.985465 = (0.1*((17.55)^2-(10.31)^2))/(2*1.01).
How to calculate Distance between Infiltration Gallery and Source given Discharge?
With Coefficient of Permeability (k), Height of Saturated Zone (H), Depth of Water in Infiltration Gallery (Ho) & Discharge (Q) we can find Distance between Infiltration Gallery and Source given Discharge using the formula - Distance Between IG and Source = (Coefficient of Permeability*((Height of Saturated Zone)^2-(Depth of Water in Infiltration Gallery)^2))/(2*Discharge).
Can the Distance between Infiltration Gallery and Source given Discharge be negative?
No, the Distance between Infiltration Gallery and Source given Discharge, measured in Length cannot be negative.
Which unit is used to measure Distance between Infiltration Gallery and Source given Discharge?
Distance between Infiltration Gallery and Source given Discharge is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Distance between Infiltration Gallery and Source given Discharge can be measured.
Copied!