Discharge Required at Outlet Formula

Fx Copy
LaTeX Copy
Discharge required at outlet is the duty at the headwater course. Check FAQs
Q°=QcontinousT
Q° - Discharge Required at Outlet?Qcontinous - Continuous Discharge Required for Canal?T - Time Factor in Irrigation?

Discharge Required at Outlet Example

With values
With units
Only example

Here is how the Discharge Required at Outlet equation looks like with Values.

Here is how the Discharge Required at Outlet equation looks like with Units.

Here is how the Discharge Required at Outlet equation looks like.

90.2256Edit=120Edit1.33Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Irrigation Engineering » fx Discharge Required at Outlet

Discharge Required at Outlet Solution

Follow our step by step solution on how to calculate Discharge Required at Outlet?

FIRST Step Consider the formula
Q°=QcontinousT
Next Step Substitute values of Variables
Q°=120m³/s1.33
Next Step Prepare to Evaluate
Q°=1201.33
Next Step Evaluate
Q°=90.2255639097744m³/s
LAST Step Rounding Answer
Q°=90.2256m³/s

Discharge Required at Outlet Formula Elements

Variables
Discharge Required at Outlet
Discharge required at outlet is the duty at the headwater course.
Symbol: Q°
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Continuous Discharge Required for Canal
continuous discharge required for canal.
Symbol: Qcontinous
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Time Factor in Irrigation
Time factor in irrigation is the ratio of the number of days the canal has actually run to the. number of days of irrigation period.
Symbol: T
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Water Requirements of Crops and Canal Irrigation category

​Go Time Factor
T=QcontinousQ°

How to Evaluate Discharge Required at Outlet?

Discharge Required at Outlet evaluator uses Discharge Required at Outlet = Continuous Discharge Required for Canal/Time Factor in Irrigation to evaluate the Discharge Required at Outlet, The Discharge Required at Outlet formula is defined as the duty at the head watercourse called as “outlet discharge”. The ratio between the area of the crop irrigated and the quantity of water required during its entire period of growth is known as duty. Discharge Required at Outlet is denoted by Q° symbol.

How to evaluate Discharge Required at Outlet using this online evaluator? To use this online evaluator for Discharge Required at Outlet, enter Continuous Discharge Required for Canal (Qcontinous) & Time Factor in Irrigation (T) and hit the calculate button.

FAQs on Discharge Required at Outlet

What is the formula to find Discharge Required at Outlet?
The formula of Discharge Required at Outlet is expressed as Discharge Required at Outlet = Continuous Discharge Required for Canal/Time Factor in Irrigation. Here is an example- 90.22556 = 120/1.33.
How to calculate Discharge Required at Outlet?
With Continuous Discharge Required for Canal (Qcontinous) & Time Factor in Irrigation (T) we can find Discharge Required at Outlet using the formula - Discharge Required at Outlet = Continuous Discharge Required for Canal/Time Factor in Irrigation.
Can the Discharge Required at Outlet be negative?
No, the Discharge Required at Outlet, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Discharge Required at Outlet?
Discharge Required at Outlet is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge Required at Outlet can be measured.
Copied!