Fx Copy
LaTeX Copy
The Discharge refers to the volume of fluid (usually water) that flows through a given cross-sectional area per unit of time. Check FAQs
Q=v'ARr
Q - Discharge?v' - Falling Speed?A - Area?Rr - Removal Ratio?

Discharge Rate given Ratio of Removal with respect to Discharge Example

With values
With units
Only example

Here is how the Discharge Rate given Ratio of Removal with respect to Discharge equation looks like with Values.

Here is how the Discharge Rate given Ratio of Removal with respect to Discharge equation looks like with Units.

Here is how the Discharge Rate given Ratio of Removal with respect to Discharge equation looks like.

0.025Edit=0.1Edit50Edit200Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Discharge Rate given Ratio of Removal with respect to Discharge

Discharge Rate given Ratio of Removal with respect to Discharge Solution

Follow our step by step solution on how to calculate Discharge Rate given Ratio of Removal with respect to Discharge?

FIRST Step Consider the formula
Q=v'ARr
Next Step Substitute values of Variables
Q=0.1m/s50200
Next Step Prepare to Evaluate
Q=0.150200
LAST Step Evaluate
Q=0.025m³/s

Discharge Rate given Ratio of Removal with respect to Discharge Formula Elements

Variables
Discharge
The Discharge refers to the volume of fluid (usually water) that flows through a given cross-sectional area per unit of time.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Falling Speed
The Falling Speed refers to the constant speed at which a particle falls through a fluid when the force of gravity is balanced by the drag force and buoyant force acting on the particle.
Symbol: v'
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Area
The Area of a sedimentation tank refers to the surface area of the tank where sedimentation, or the settling of suspended particles, occurs.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Removal Ratio
The Removal Ratio refers to the total amount of sludge removed from the sedimentation tank.
Symbol: Rr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Discharge

​Go Discharge Rate given Vertical Falling Speed in Sedimentation Tank
Q=VsLw
​Go Discharge Rate given Vertical Falling Speed in Sedimentation Tank with respect to Area
Q=VsA
​Go Discharge Rate given Detention Time
Q=LwhTd
​Go Discharge Rate given Height at Outlet Zone with respect to Discharge
Q=Lwhv'H

How to Evaluate Discharge Rate given Ratio of Removal with respect to Discharge?

Discharge Rate given Ratio of Removal with respect to Discharge evaluator uses Discharge = Falling Speed*Area/Removal Ratio to evaluate the Discharge, The Discharge Rate given Ratio of Removal with respect to Discharge formula is defined as amount of sludge being removed from sedimentation tank. Discharge is denoted by Q symbol.

How to evaluate Discharge Rate given Ratio of Removal with respect to Discharge using this online evaluator? To use this online evaluator for Discharge Rate given Ratio of Removal with respect to Discharge, enter Falling Speed (v'), Area (A) & Removal Ratio (Rr) and hit the calculate button.

FAQs on Discharge Rate given Ratio of Removal with respect to Discharge

What is the formula to find Discharge Rate given Ratio of Removal with respect to Discharge?
The formula of Discharge Rate given Ratio of Removal with respect to Discharge is expressed as Discharge = Falling Speed*Area/Removal Ratio. Here is an example- 0.025 = 0.1*50/200.
How to calculate Discharge Rate given Ratio of Removal with respect to Discharge?
With Falling Speed (v'), Area (A) & Removal Ratio (Rr) we can find Discharge Rate given Ratio of Removal with respect to Discharge using the formula - Discharge = Falling Speed*Area/Removal Ratio.
What are the other ways to Calculate Discharge?
Here are the different ways to Calculate Discharge-
  • Discharge=Settling Velocity*Length*WidthOpenImg
  • Discharge=Settling Velocity*AreaOpenImg
  • Discharge=Length*Width*Height of Crack/Detention TimeOpenImg
Can the Discharge Rate given Ratio of Removal with respect to Discharge be negative?
Yes, the Discharge Rate given Ratio of Removal with respect to Discharge, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Discharge Rate given Ratio of Removal with respect to Discharge?
Discharge Rate given Ratio of Removal with respect to Discharge is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge Rate given Ratio of Removal with respect to Discharge can be measured.
Copied!