Discharge Passing through Vertical Section of Infiltration Gallery Formula

Fx Copy
LaTeX Copy
The Discharge refers to the volume of fluid passing through a cross-sectional area of a stream or pipe per unit time. Check FAQs
Q=k((H)2-(Ho)2)2L
Q - Discharge?k - Coefficient of Permeability?H - Height of Saturated Zone?Ho - Depth of Water in Infiltration Gallery?L - Distance Between IG and Source?

Discharge Passing through Vertical Section of Infiltration Gallery Example

With values
With units
Only example

Here is how the Discharge Passing through Vertical Section of Infiltration Gallery equation looks like with Values.

Here is how the Discharge Passing through Vertical Section of Infiltration Gallery equation looks like with Units.

Here is how the Discharge Passing through Vertical Section of Infiltration Gallery equation looks like.

1.0085Edit=10Edit((17.55Edit)2-(10.31Edit)2)210Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Discharge Passing through Vertical Section of Infiltration Gallery

Discharge Passing through Vertical Section of Infiltration Gallery Solution

Follow our step by step solution on how to calculate Discharge Passing through Vertical Section of Infiltration Gallery?

FIRST Step Consider the formula
Q=k((H)2-(Ho)2)2L
Next Step Substitute values of Variables
Q=10cm/s((17.55m)2-(10.31m)2)210m
Next Step Convert Units
Q=0.1m/s((17.55m)2-(10.31m)2)210m
Next Step Prepare to Evaluate
Q=0.1((17.55)2-(10.31)2)210
Next Step Evaluate
Q=1.008532m³/s
LAST Step Rounding Answer
Q=1.0085m³/s

Discharge Passing through Vertical Section of Infiltration Gallery Formula Elements

Variables
Discharge
The Discharge refers to the volume of fluid passing through a cross-sectional area of a stream or pipe per unit time.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Coefficient of Permeability
The Coefficient of Permeability refers to the soil characteristics describes how easily a liquid will move through the soil.
Symbol: k
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Height of Saturated Zone
The Height of saturated Zone refers to the height of the ground level at the infiltration gallery which is considered at some distance from the source.
Symbol: H
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Depth of Water in Infiltration Gallery
The Depth of Water in Infiltration Gallery refers to the depth of water which is considered inside the infiltration gallery.
Symbol: Ho
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Distance Between IG and Source
The Distance Between IG and Source refers to the distance between the infiltration gallery and the source point.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other formulas in Flow into Infiltration Gallery category

​Go Coefficient of Permeability given Discharge
k=Q(H)2-(Ho)22L
​Go Distance between Infiltration Gallery and Source given Discharge
L=k((H)2-(Ho)2)2Q
​Go Height of Saturated Zone given Discharge
H=(2QLk)+(Ho)2
​Go Depth of Water in Gallery given Discharge
Ho=(H)2-(2QLk)

How to Evaluate Discharge Passing through Vertical Section of Infiltration Gallery?

Discharge Passing through Vertical Section of Infiltration Gallery evaluator uses Discharge = (Coefficient of Permeability*((Height of Saturated Zone)^2-(Depth of Water in Infiltration Gallery)^2))/(2*Distance Between IG and Source) to evaluate the Discharge, The Discharge Passing through Vertical Section of Infiltration Gallery is defined as the value of discharge passing through the vertical section when we have prior information of other parameters used. Discharge is denoted by Q symbol.

How to evaluate Discharge Passing through Vertical Section of Infiltration Gallery using this online evaluator? To use this online evaluator for Discharge Passing through Vertical Section of Infiltration Gallery, enter Coefficient of Permeability (k), Height of Saturated Zone (H), Depth of Water in Infiltration Gallery (Ho) & Distance Between IG and Source (L) and hit the calculate button.

FAQs on Discharge Passing through Vertical Section of Infiltration Gallery

What is the formula to find Discharge Passing through Vertical Section of Infiltration Gallery?
The formula of Discharge Passing through Vertical Section of Infiltration Gallery is expressed as Discharge = (Coefficient of Permeability*((Height of Saturated Zone)^2-(Depth of Water in Infiltration Gallery)^2))/(2*Distance Between IG and Source). Here is an example- 1.008532 = (0.1*((17.55)^2-(10.31)^2))/(2*10).
How to calculate Discharge Passing through Vertical Section of Infiltration Gallery?
With Coefficient of Permeability (k), Height of Saturated Zone (H), Depth of Water in Infiltration Gallery (Ho) & Distance Between IG and Source (L) we can find Discharge Passing through Vertical Section of Infiltration Gallery using the formula - Discharge = (Coefficient of Permeability*((Height of Saturated Zone)^2-(Depth of Water in Infiltration Gallery)^2))/(2*Distance Between IG and Source).
Can the Discharge Passing through Vertical Section of Infiltration Gallery be negative?
Yes, the Discharge Passing through Vertical Section of Infiltration Gallery, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Discharge Passing through Vertical Section of Infiltration Gallery?
Discharge Passing through Vertical Section of Infiltration Gallery is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge Passing through Vertical Section of Infiltration Gallery can be measured.
Copied!