Fx Copy
LaTeX Copy
Discharge is the flow rate of water that is extracted from or injected into a well. Check FAQs
Q=1.36KWH(bw2-hw2)log((Rwr),10)
Q - Discharge?KWH - Coefficient of Permeability in Well Hydraulics?bw - Aquifer Thickness?hw - Depth of Water?Rw - Radius of Influence?r - Radius of Well?

Discharge in Unconfined Aquifer with Base 10 Example

With values
With units
Only example

Here is how the Discharge in Unconfined Aquifer with Base 10 equation looks like with Values.

Here is how the Discharge in Unconfined Aquifer with Base 10 equation looks like with Units.

Here is how the Discharge in Unconfined Aquifer with Base 10 equation looks like.

1.5704Edit=1.3610Edit(14.15Edit2-2.44Edit2)log((8.6Edit7.5Edit),10)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Discharge in Unconfined Aquifer with Base 10

Discharge in Unconfined Aquifer with Base 10 Solution

Follow our step by step solution on how to calculate Discharge in Unconfined Aquifer with Base 10?

FIRST Step Consider the formula
Q=1.36KWH(bw2-hw2)log((Rwr),10)
Next Step Substitute values of Variables
Q=1.3610cm/s(14.15m2-2.44m2)log((8.6m7.5m),10)
Next Step Convert Units
Q=1.360.1m/s(14.15m2-2.44m2)log((8.6m7.5m),10)
Next Step Prepare to Evaluate
Q=1.360.1(14.152-2.442)log((8.67.5),10)
Next Step Evaluate
Q=1.5703644060183m³/s
LAST Step Rounding Answer
Q=1.5704m³/s

Discharge in Unconfined Aquifer with Base 10 Formula Elements

Variables
Functions
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Coefficient of Permeability in Well Hydraulics
Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil.
Symbol: KWH
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Aquifer Thickness
Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Symbol: bw
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Depth of Water
Depth of Water is the depth in the well measured above the impermeable layer.
Symbol: hw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Influence
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Symbol: Rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Well
Radius of Well is defined as the distance from center of well to its outer boundary.
Symbol: r
Measurement: LengthUnit: m
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Discharge

​Go Rate of Flow given Flow Velocity
Q=(Vwh'Asec)
​Go Discharge in Unconfined Aquifer
Q=πKWH(H2-hw2)log((Rwr),e)
​Go Discharge when Two Observation Well is Taken
Q=πKWH(h22-h12)log((r2r1),e)
​Go Discharge from Two Wells with Base 10
Q=1.36KWH(h22-h12)log((r2r1'),10)

How to Evaluate Discharge in Unconfined Aquifer with Base 10?

Discharge in Unconfined Aquifer with Base 10 evaluator uses Discharge = (1.36*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness^2-Depth of Water^2))/(log((Radius of Influence/Radius of Well),10)) to evaluate the Discharge, The Discharge in Unconfined Aquifer with Base 10 is defined as the value of discharge in unconfined aquifer when we have prior information of other parameters used. Discharge is denoted by Q symbol.

How to evaluate Discharge in Unconfined Aquifer with Base 10 using this online evaluator? To use this online evaluator for Discharge in Unconfined Aquifer with Base 10, enter Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness (bw), Depth of Water (hw), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button.

FAQs on Discharge in Unconfined Aquifer with Base 10

What is the formula to find Discharge in Unconfined Aquifer with Base 10?
The formula of Discharge in Unconfined Aquifer with Base 10 is expressed as Discharge = (1.36*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness^2-Depth of Water^2))/(log((Radius of Influence/Radius of Well),10)). Here is an example- 1.770652 = (1.36*0.1*(14.15^2-2.44^2))/(log((8.6/7.5),10)).
How to calculate Discharge in Unconfined Aquifer with Base 10?
With Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness (bw), Depth of Water (hw), Radius of Influence (Rw) & Radius of Well (r) we can find Discharge in Unconfined Aquifer with Base 10 using the formula - Discharge = (1.36*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness^2-Depth of Water^2))/(log((Radius of Influence/Radius of Well),10)). This formula also uses Logarithmic Inverse Function function(s).
What are the other ways to Calculate Discharge?
Here are the different ways to Calculate Discharge-
  • Discharge=(Velocity of Flow*Area of Cross Section)OpenImg
  • Discharge=(pi*Coefficient of Permeability in Well Hydraulics*(Thickness of Unconfined Aquifer^2-Depth of Water^2))/(log((Radius of Influence/Radius of Well),e))OpenImg
  • Discharge=(pi*Coefficient of Permeability in Well Hydraulics*(Depth of Water 2^2-Depth of Water 1^2))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),e))OpenImg
Can the Discharge in Unconfined Aquifer with Base 10 be negative?
Yes, the Discharge in Unconfined Aquifer with Base 10, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Discharge in Unconfined Aquifer with Base 10?
Discharge in Unconfined Aquifer with Base 10 is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge in Unconfined Aquifer with Base 10 can be measured.
Copied!