Fx Copy
LaTeX Copy
Discharge in Confined Aquifer is the amount of water that is released from a confined aquifer. Check FAQs
Qc=2.72Tw(Hi-hw)log((Rwr),10)
Qc - Discharge in Confined Aquifer?Tw - Coefficient of Transmissibility in Enviro. Eng.?Hi - Initial Aquifer Thickness?hw - Depth of Water?Rw - Radius of Influence?r - Radius of Well?

Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility Example

With values
With units
Only example

Here is how the Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility equation looks like with Values.

Here is how the Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility equation looks like with Units.

Here is how the Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility equation looks like.

0.174Edit=2.7226.9Edit(2.48Edit-2.44Edit)log((8.6Edit7.5Edit),10)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility

Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility Solution

Follow our step by step solution on how to calculate Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility?

FIRST Step Consider the formula
Qc=2.72Tw(Hi-hw)log((Rwr),10)
Next Step Substitute values of Variables
Qc=2.7226.9m²/s(2.48m-2.44m)log((8.6m7.5m),10)
Next Step Prepare to Evaluate
Qc=2.7226.9(2.48-2.44)log((8.67.5),10)
Next Step Evaluate
Qc=0.173956006429818m³/s
LAST Step Rounding Answer
Qc=0.174m³/s

Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility Formula Elements

Variables
Functions
Discharge in Confined Aquifer
Discharge in Confined Aquifer is the amount of water that is released from a confined aquifer.
Symbol: Qc
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Coefficient of Transmissibility in Enviro. Eng.
Coefficient of Transmissibility in Enviro. Eng. is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Symbol: Tw
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Initial Aquifer Thickness
Initial Aquifer Thickness is the aquifer thickness at initial stage before pumping.
Symbol: Hi
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Depth of Water
Depth of Water is the depth in the well measured above the impermeable layer.
Symbol: hw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Influence
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Symbol: Rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Well
Radius of Well is defined as the distance from center of well to its outer boundary.
Symbol: r
Measurement: LengthUnit: m
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Discharge in Confined Aquifer

​Go Discharge in Confined Aquifer
Qc=2πKWHbw(Hi-hw)log((Rwr),e)

Other formulas in Aquifer Discharge category

​Go Discharge in Confined Aquifer with Base 10
Q=2.72Kwbw(Hi-hw)log((Rwr),10)
​Go Discharge in Confined Aquifer given Coefficient of Transmissibility
Qct=2πTw(Hi-hw)log((Rwr),e)
​Go Confined Aquifer Discharge given Drawdown at Well
Q=2πKWHbpStwlog((Rwr),e)
​Go Confined Aquifer Discharge with Base 10 given Drawdown at Well
Q=2.72KWHbwStwlog((Rwr),10)

How to Evaluate Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility?

Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility evaluator uses Discharge in Confined Aquifer = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10)) to evaluate the Discharge in Confined Aquifer, The Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility formula is defined as the value of discharge in confined aquifer when we have prior information of coefficient of transmissibility. Discharge in Confined Aquifer is denoted by Qc symbol.

How to evaluate Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility using this online evaluator? To use this online evaluator for Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility, enter Coefficient of Transmissibility in Enviro. Eng. (Tw), Initial Aquifer Thickness (Hi), Depth of Water (hw), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button.

FAQs on Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility

What is the formula to find Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility?
The formula of Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility is expressed as Discharge in Confined Aquifer = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10)). Here is an example- 0.173956 = (2.72*26.9*(2.48-2.44))/(log((8.6/7.5),10)).
How to calculate Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility?
With Coefficient of Transmissibility in Enviro. Eng. (Tw), Initial Aquifer Thickness (Hi), Depth of Water (hw), Radius of Influence (Rw) & Radius of Well (r) we can find Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility using the formula - Discharge in Confined Aquifer = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10)). This formula also uses Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Discharge in Confined Aquifer?
Here are the different ways to Calculate Discharge in Confined Aquifer-
  • Discharge in Confined Aquifer=(2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),e))OpenImg
Can the Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility be negative?
No, the Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility?
Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility can be measured.
Copied!