Fx Copy
LaTeX Copy
The Discharge through mouthpiece is considered in the flow without sudden enlargement. Check FAQs
QM=0.5A29.81Hc
QM - Discharge through Mouthpiece?A - Area?Hc - Constant Head?

Discharge in Borda's Mouthpiece Running Free Example

With values
With units
Only example

Here is how the Discharge in Borda's Mouthpiece Running Free equation looks like with Values.

Here is how the Discharge in Borda's Mouthpiece Running Free equation looks like with Units.

Here is how the Discharge in Borda's Mouthpiece Running Free equation looks like.

36.6003Edit=0.55.1Edit29.8110.5Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Fluid Mechanics » fx Discharge in Borda's Mouthpiece Running Free

Discharge in Borda's Mouthpiece Running Free Solution

Follow our step by step solution on how to calculate Discharge in Borda's Mouthpiece Running Free?

FIRST Step Consider the formula
QM=0.5A29.81Hc
Next Step Substitute values of Variables
QM=0.55.129.8110.5m
Next Step Prepare to Evaluate
QM=0.55.129.8110.5
Next Step Evaluate
QM=36.6002735645514m³/s
LAST Step Rounding Answer
QM=36.6003m³/s

Discharge in Borda's Mouthpiece Running Free Formula Elements

Variables
Functions
Discharge through Mouthpiece
The Discharge through mouthpiece is considered in the flow without sudden enlargement.
Symbol: QM
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Area
The area is the amount of two-dimensional space taken up by an object.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Constant Head
The Constant head is considered for discharging of the water from an mouthpiece.
Symbol: Hc
Measurement: LengthUnit: m
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Discharge through Mouthpiece

​Go Discharge in Convergent-Divergent Mouthpiece
QM=ac29.81Hc
​Go Discharge in Borda's Mouthpiece Running Full
QM=0.707A29.81Hc

Other formulas in Flow Rate category

​Go Coefficient of discharge
Cd=QaQth
​Go Coefficient of discharge for area and velocity
Cd=vaAaVthAt
​Go Coefficient of Discharge given Time for Emptying Tank
Cd=2AT((Hi)-(Hf))ttotala29.81
​Go Coefficient of Discharge given Time of Emptying Hemispherical Tank
Cd=π(((43)Rt((Hi32)-(Hf32)))-((25)((Hi52)-(Hf)52)))ttotala(29.81)

How to Evaluate Discharge in Borda's Mouthpiece Running Free?

Discharge in Borda's Mouthpiece Running Free evaluator uses Discharge through Mouthpiece = 0.5*Area*sqrt(2*9.81*Constant Head) to evaluate the Discharge through Mouthpiece, The Discharge in Borda's Mouthpiece Running Free formula is considered where the length of the tube is equal to its diameter, and the jet of liquid comes out from the mouthpiece without touching the sides of the tube. Discharge through Mouthpiece is denoted by QM symbol.

How to evaluate Discharge in Borda's Mouthpiece Running Free using this online evaluator? To use this online evaluator for Discharge in Borda's Mouthpiece Running Free, enter Area (A) & Constant Head (Hc) and hit the calculate button.

FAQs on Discharge in Borda's Mouthpiece Running Free

What is the formula to find Discharge in Borda's Mouthpiece Running Free?
The formula of Discharge in Borda's Mouthpiece Running Free is expressed as Discharge through Mouthpiece = 0.5*Area*sqrt(2*9.81*Constant Head). Here is an example- 36.60027 = 0.5*5.1*sqrt(2*9.81*10.5).
How to calculate Discharge in Borda's Mouthpiece Running Free?
With Area (A) & Constant Head (Hc) we can find Discharge in Borda's Mouthpiece Running Free using the formula - Discharge through Mouthpiece = 0.5*Area*sqrt(2*9.81*Constant Head). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Discharge through Mouthpiece?
Here are the different ways to Calculate Discharge through Mouthpiece-
  • Discharge through Mouthpiece=Area at Vena Contracta*sqrt(2*9.81*Constant Head)OpenImg
  • Discharge through Mouthpiece=0.707*Area*sqrt(2*9.81*Constant Head)OpenImg
Can the Discharge in Borda's Mouthpiece Running Free be negative?
Yes, the Discharge in Borda's Mouthpiece Running Free, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Discharge in Borda's Mouthpiece Running Free?
Discharge in Borda's Mouthpiece Running Free is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge in Borda's Mouthpiece Running Free can be measured.
Copied!