Fx Copy
LaTeX Copy
Discharge is the rate of flow of a liquid. Check FAQs
Q=100SABasevs70
Q - Discharge?SABase - Base Surface Area?vs - Settling Velocity?

Discharge given Plan Area for Particular Sized Particle Example

With values
With units
Only example

Here is how the Discharge given Plan Area for Particular Sized Particle equation looks like with Values.

Here is how the Discharge given Plan Area for Particular Sized Particle equation looks like with Units.

Here is how the Discharge given Plan Area for Particular Sized Particle equation looks like.

4.2857Edit=1002Edit1.5Edit70
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Discharge given Plan Area for Particular Sized Particle

Discharge given Plan Area for Particular Sized Particle Solution

Follow our step by step solution on how to calculate Discharge given Plan Area for Particular Sized Particle?

FIRST Step Consider the formula
Q=100SABasevs70
Next Step Substitute values of Variables
Q=10021.5m/s70
Next Step Prepare to Evaluate
Q=10021.570
Next Step Evaluate
Q=4.28571428571429m³/s
LAST Step Rounding Answer
Q=4.2857m³/s

Discharge given Plan Area for Particular Sized Particle Formula Elements

Variables
Discharge
Discharge is the rate of flow of a liquid.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Base Surface Area
Base Surface Area is the total area of the base or bottom surface of a sedimentation tank.
Symbol: SABase
Measurement: AreaUnit:
Note: Value should be greater than 0.
Settling Velocity
Settling Velocity is defined as the terminal velocity of a particle in still fluid.
Symbol: vs
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.

Other Formulas to find Discharge

​Go Discharge given Plan Area
Q=vsSABase
​Go Discharge given Height to Length Ratio
Q=vswdHL
​Go Discharge given Overflow Rate
Q=(SORwL)
​Go Discharge given Detention Time for Rectangular Tank
Q=(wLdTd)

Other formulas in Discharge in Tank category

​Go Discharge Entering Basin given Flow Velocity
Qv=(Vfwd)
​Go Discharge Entering Basin given Cross-section Area of Tank
Qa=VfAcs
​Go Discharge Entering Basin given Settling Velocity
Qs=(vswL)
​Go Discharge given Settling Velocity of Particular Sized Particle
Qs=100vswL70

How to Evaluate Discharge given Plan Area for Particular Sized Particle?

Discharge given Plan Area for Particular Sized Particle evaluator uses Discharge = (100*Base Surface Area*Settling Velocity)/70 to evaluate the Discharge, The Discharge given Plan Area for Particular Sized Particle formula is defined as the calculation of the volumetric flow rate of fluid (usually water) entering a basin or tank, based on the plan area for particular sized particle. Discharge is denoted by Q symbol.

How to evaluate Discharge given Plan Area for Particular Sized Particle using this online evaluator? To use this online evaluator for Discharge given Plan Area for Particular Sized Particle, enter Base Surface Area (SABase) & Settling Velocity (vs) and hit the calculate button.

FAQs on Discharge given Plan Area for Particular Sized Particle

What is the formula to find Discharge given Plan Area for Particular Sized Particle?
The formula of Discharge given Plan Area for Particular Sized Particle is expressed as Discharge = (100*Base Surface Area*Settling Velocity)/70. Here is an example- 10.71429 = (100*2*1.5)/70.
How to calculate Discharge given Plan Area for Particular Sized Particle?
With Base Surface Area (SABase) & Settling Velocity (vs) we can find Discharge given Plan Area for Particular Sized Particle using the formula - Discharge = (100*Base Surface Area*Settling Velocity)/70.
What are the other ways to Calculate Discharge?
Here are the different ways to Calculate Discharge-
  • Discharge=Settling Velocity*Base Surface AreaOpenImg
  • Discharge=(Settling Velocity*Width*Depth)/Ratio of Height to LengthOpenImg
  • Discharge=(Overflow Rate*Width*Length)OpenImg
Can the Discharge given Plan Area for Particular Sized Particle be negative?
No, the Discharge given Plan Area for Particular Sized Particle, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Discharge given Plan Area for Particular Sized Particle?
Discharge given Plan Area for Particular Sized Particle is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge given Plan Area for Particular Sized Particle can be measured.
Copied!