Fx Copy
LaTeX Copy
Discharge is the rate of flow of a fluid in unsteady flow. Check FAQs
Q=Fc2.3034πΔd
Q - Discharge?Fc - Formation Constant for Unsteady Flow?Δd - Change in Drawdown?π - Archimedes' constant?

Discharge given Formation Constant T Example

With values
With units
Only example

Here is how the Discharge given Formation Constant T equation looks like with Values.

Here is how the Discharge given Formation Constant T equation looks like with Units.

Here is how the Discharge given Formation Constant T equation looks like.

1.004Edit=0.8Edit2.30343.14160.23Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Discharge given Formation Constant T

Discharge given Formation Constant T Solution

Follow our step by step solution on how to calculate Discharge given Formation Constant T?

FIRST Step Consider the formula
Q=Fc2.3034πΔd
Next Step Substitute values of Variables
Q=0.8m²/s2.3034π0.23m
Next Step Substitute values of Constants
Q=0.8m²/s2.30343.14160.23m
Next Step Prepare to Evaluate
Q=0.82.30343.14160.23
Next Step Evaluate
Q=1.00400008382201m³/s
LAST Step Rounding Answer
Q=1.004m³/s

Discharge given Formation Constant T Formula Elements

Variables
Constants
Discharge
Discharge is the rate of flow of a fluid in unsteady flow.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Formation Constant for Unsteady Flow
Formation Constant for Unsteady Flow is an equilibrium constant for the formation of a complex in solution.
Symbol: Fc
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Change in Drawdown
Change in Drawdown is defined as the difference at the two wells.
Symbol: Δd
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other Formulas to find Discharge

​Go Discharge given Drawdown
Q=4πFcstWu
​Go Discharge given Time at 1st and 2nd Instance
Q=Δd2.303log((t2sect1),10)4πthr

How to Evaluate Discharge given Formation Constant T?

Discharge given Formation Constant T evaluator uses Discharge = Formation Constant for Unsteady Flow/((2.303)/(4*pi*Change in Drawdown)) to evaluate the Discharge, Discharge given Formation Constant T formula is defined as a measure of the rate of fluid flow in an unsteady flow context, where the formation constant and other parameters are used to quantify the flow rate, providing valuable insights into the fluid's behavior and movement. Discharge is denoted by Q symbol.

How to evaluate Discharge given Formation Constant T using this online evaluator? To use this online evaluator for Discharge given Formation Constant T, enter Formation Constant for Unsteady Flow (Fc) & Change in Drawdown (Δd) and hit the calculate button.

FAQs on Discharge given Formation Constant T

What is the formula to find Discharge given Formation Constant T?
The formula of Discharge given Formation Constant T is expressed as Discharge = Formation Constant for Unsteady Flow/((2.303)/(4*pi*Change in Drawdown)). Here is an example- 1.01655 = 0.8/((2.303)/(4*pi*0.23)).
How to calculate Discharge given Formation Constant T?
With Formation Constant for Unsteady Flow (Fc) & Change in Drawdown (Δd) we can find Discharge given Formation Constant T using the formula - Discharge = Formation Constant for Unsteady Flow/((2.303)/(4*pi*Change in Drawdown)). This formula also uses Archimedes' constant .
What are the other ways to Calculate Discharge?
Here are the different ways to Calculate Discharge-
  • Discharge=(4*pi*Formation Constant for Unsteady Flow*Total Drawdown in Well)/Well Function of uOpenImg
  • Discharge=Change in Drawdown/((2.303*log((Time of Drawdown (t2) in Wells/Time of Drawdown (t1) in Wells),10))/(4*pi*Time in Hours for Well Discharge))OpenImg
Can the Discharge given Formation Constant T be negative?
Yes, the Discharge given Formation Constant T, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Discharge given Formation Constant T?
Discharge given Formation Constant T is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge given Formation Constant T can be measured.
Copied!