Discharge refers to the volume of water that flows through the aquifer over a given period. Check FAQs
Qw=T2.72Δs
Qw - Discharge?T - Aquifer Constant?Δs - Difference in Drawdowns?

Discharge given Difference in Drawdowns at Two Wells Example

With values
With units
Only example

Here is how the Discharge given Difference in Drawdowns at Two Wells equation looks like with Values.

Here is how the Discharge given Difference in Drawdowns at Two Wells equation looks like with Units.

Here is how the Discharge given Difference in Drawdowns at Two Wells equation looks like.

0.9394Edit=24.67Edit2.720.014Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Discharge given Difference in Drawdowns at Two Wells

Discharge given Difference in Drawdowns at Two Wells Solution

Follow our step by step solution on how to calculate Discharge given Difference in Drawdowns at Two Wells?

FIRST Step Consider the formula
Qw=T2.72Δs
Next Step Substitute values of Variables
Qw=24.672.720.014m
Next Step Prepare to Evaluate
Qw=24.672.720.014
Next Step Evaluate
Qw=0.9394336m³/s
LAST Step Rounding Answer
Qw=0.9394m³/s

Discharge given Difference in Drawdowns at Two Wells Formula Elements

Variables
Discharge
Discharge refers to the volume of water that flows through the aquifer over a given period.
Symbol: Qw
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Aquifer Constant
Aquifer Constant refers to the product of the hydraulic conductivity (K) and the thickness (b) of an aquifer and also known as coefficient of transmissibility.
Symbol: T
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Difference in Drawdowns
The difference in Drawdowns refers to the difference between drawdowns of two wells.
Symbol: Δs
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Discharge

​Go Discharge given Aquifer Constant
Qw=T12.72(s1-s2)

Other formulas in Discharge And Drawdown in Well category

​Go Drawdown in Well 1 given Thickness of Aquifer from Impermeable Layer
s1=H-h1
​Go Drawdown in Well 2 given Thickness of Aquifer from Impermeable Layer
s2=H-h2
​Go Drawdown in Well 1 given Aquifer Constant
s1=s2+(Qwlog((r2r1),10)2.72T)
​Go Drawdown in Well 2 given Aquifer Constant
s2=s1-(Qwlog((r2r1),10)2.72T)

How to Evaluate Discharge given Difference in Drawdowns at Two Wells?

Discharge given Difference in Drawdowns at Two Wells evaluator uses Discharge = Aquifer Constant*2.72*Difference in Drawdowns to evaluate the Discharge, Discharge given Difference in Drawdowns at Two Wells formula is defined as a method to estimate the rate of fluid flow in a confined aquifer system, providing valuable insights into the groundwater flow dynamics and aquifer properties, particularly in scenarios where two wells are involved. Discharge is denoted by Qw symbol.

How to evaluate Discharge given Difference in Drawdowns at Two Wells using this online evaluator? To use this online evaluator for Discharge given Difference in Drawdowns at Two Wells, enter Aquifer Constant (T) & Difference in Drawdowns (Δs) and hit the calculate button.

FAQs on Discharge given Difference in Drawdowns at Two Wells

What is the formula to find Discharge given Difference in Drawdowns at Two Wells?
The formula of Discharge given Difference in Drawdowns at Two Wells is expressed as Discharge = Aquifer Constant*2.72*Difference in Drawdowns. Here is an example- 0.939434 = 24.67*2.72*0.014.
How to calculate Discharge given Difference in Drawdowns at Two Wells?
With Aquifer Constant (T) & Difference in Drawdowns (Δs) we can find Discharge given Difference in Drawdowns at Two Wells using the formula - Discharge = Aquifer Constant*2.72*Difference in Drawdowns.
What are the other ways to Calculate Discharge?
Here are the different ways to Calculate Discharge-
  • Discharge=Aquifer Constant/((1)/(2.72*(Drawdown in Well 1-Drawdown in Well 2)))OpenImg
Can the Discharge given Difference in Drawdowns at Two Wells be negative?
No, the Discharge given Difference in Drawdowns at Two Wells, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Discharge given Difference in Drawdowns at Two Wells?
Discharge given Difference in Drawdowns at Two Wells is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge given Difference in Drawdowns at Two Wells can be measured.