Fx Copy
LaTeX Copy
The Volume Flow Rate refers to the volume of fluid that passes per unit of time. Check FAQs
Q=AsCd(2gH)12
Q - Volume Flow Rate?As - Area for Siphon Throat?Cd - Coefficient of Discharge?g - Acceleration due to Gravity?H - Head of Liquid?

Discharge given Area for Siphon Throat Example

With values
With units
Only example

Here is how the Discharge given Area for Siphon Throat equation looks like with Values.

Here is how the Discharge given Area for Siphon Throat equation looks like with Units.

Here is how the Discharge given Area for Siphon Throat equation looks like.

1.9341Edit=0.12Edit0.94Edit(29.8Edit15Edit)12
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Discharge given Area for Siphon Throat

Discharge given Area for Siphon Throat Solution

Follow our step by step solution on how to calculate Discharge given Area for Siphon Throat?

FIRST Step Consider the formula
Q=AsCd(2gH)12
Next Step Substitute values of Variables
Q=0.120.94(29.8m/s²15m)12
Next Step Prepare to Evaluate
Q=0.120.94(29.815)12
Next Step Evaluate
Q=1.9341171009016m³/s
LAST Step Rounding Answer
Q=1.9341m³/s

Discharge given Area for Siphon Throat Formula Elements

Variables
Volume Flow Rate
The Volume Flow Rate refers to the volume of fluid that passes per unit of time.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Area for Siphon Throat
The Area for Siphon Throat refers to the area of the siphon from where the discharge is released.
Symbol: As
Measurement: AreaUnit:
Note: Value should be greater than 0.
Coefficient of Discharge
The Coefficient of Discharge or efflux coefficient refers to the ratio of the actual discharge to the theoretical discharge.
Symbol: Cd
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Acceleration due to Gravity
Acceleration due to Gravity is acceleration gained by an object because of gravitational force.
Symbol: g
Measurement: AccelerationUnit: m/s²
Note: Value should be greater than 0.
Head of Liquid
The Head of Liquid refers to the height of a liquid column that corresponds to a particular pressure exerted by the liquid column from the base of its container.
Symbol: H
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Volume Flow Rate

​Go Flow Diversion for Side Weir
Q=3.32Lweir0.83h1.67

Other formulas in Controlling Sewer Water Flow category

​Go Area for Siphon Throat
Asiphon=QCd(2gH)12
​Go Coefficient of Discharge given Area for Siphon Throat
Cd'=QAs(2gH)12
​Go Head given Area for Siphon Throat
H=(QAsCd)2(12g)
​Go Depth of Flow over Weir given Flow Diversion
h=(Q3.32(Lweir)0.83)11.67

How to Evaluate Discharge given Area for Siphon Throat?

Discharge given Area for Siphon Throat evaluator uses Volume Flow Rate = Area for Siphon Throat*Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2) to evaluate the Volume Flow Rate, The Discharge given Area for Siphon Throat is defined as the total volume flow rate of a siphon when the area of the throat of the siphon is known. Volume Flow Rate is denoted by Q symbol.

How to evaluate Discharge given Area for Siphon Throat using this online evaluator? To use this online evaluator for Discharge given Area for Siphon Throat, enter Area for Siphon Throat (As), Coefficient of Discharge (Cd), Acceleration due to Gravity (g) & Head of Liquid (H) and hit the calculate button.

FAQs on Discharge given Area for Siphon Throat

What is the formula to find Discharge given Area for Siphon Throat?
The formula of Discharge given Area for Siphon Throat is expressed as Volume Flow Rate = Area for Siphon Throat*Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2). Here is an example- 1.934117 = 0.12*0.94*(2*9.8*15)^(1/2).
How to calculate Discharge given Area for Siphon Throat?
With Area for Siphon Throat (As), Coefficient of Discharge (Cd), Acceleration due to Gravity (g) & Head of Liquid (H) we can find Discharge given Area for Siphon Throat using the formula - Volume Flow Rate = Area for Siphon Throat*Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2).
What are the other ways to Calculate Volume Flow Rate?
Here are the different ways to Calculate Volume Flow Rate-
  • Volume Flow Rate=3.32*Length of Weir^(0.83)*Depth of Flow Over Weir^(1.67)OpenImg
Can the Discharge given Area for Siphon Throat be negative?
No, the Discharge given Area for Siphon Throat, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Discharge given Area for Siphon Throat?
Discharge given Area for Siphon Throat is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge given Area for Siphon Throat can be measured.
Copied!