Discharge for Fully Penetrating Well given Correction Factor Formula

Fx Copy
LaTeX Copy
Discharge for Fully Penetrating Gravity Well refers to the volume of water extracted from an unconfined aquifer where the well reaches the entire thickness of the aquifer. Check FAQs
Qfe=QvG
Qfe - Discharge for Fully Penetrating Gravity Well?Qv - Discharge for Partially Penetrating Well?G - Correction Factor?

Discharge for Fully Penetrating Well given Correction Factor Example

With values
With units
Only example

Here is how the Discharge for Fully Penetrating Well given Correction Factor equation looks like with Values.

Here is how the Discharge for Fully Penetrating Well given Correction Factor equation looks like with Units.

Here is how the Discharge for Fully Penetrating Well given Correction Factor equation looks like.

6.1205Edit=5.08Edit0.83Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Discharge for Fully Penetrating Well given Correction Factor

Discharge for Fully Penetrating Well given Correction Factor Solution

Follow our step by step solution on how to calculate Discharge for Fully Penetrating Well given Correction Factor?

FIRST Step Consider the formula
Qfe=QvG
Next Step Substitute values of Variables
Qfe=5.08m³/s0.83
Next Step Prepare to Evaluate
Qfe=5.080.83
Next Step Evaluate
Qfe=6.12048192771084m³/s
LAST Step Rounding Answer
Qfe=6.1205m³/s

Discharge for Fully Penetrating Well given Correction Factor Formula Elements

Variables
Discharge for Fully Penetrating Gravity Well
Discharge for Fully Penetrating Gravity Well refers to the volume of water extracted from an unconfined aquifer where the well reaches the entire thickness of the aquifer.
Symbol: Qfe
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Discharge for Partially Penetrating Well
Discharge for Partially Penetrating Well refers to the volume of water extracted from an aquifer when the well does not extend through the entire thickness of the aquifer.
Symbol: Qv
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Correction Factor
Correction Factor refers to the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness.
Symbol: G
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Partially Penetrating Artesian Well category

​Go Discharge for Partially Penetrating Well
Qv=2πKb(H-hw)Glog((Rr),e)
​Go Coefficient of Permeability given Discharge for Partially Penetrating Well
K=Qv2πb(H-hw)Glog((Rr),e)
​Go Aquifer Thickness given Discharge for Partially Penetrating Well
b=Qv2πK(H-hw)Glog((Rr),e)
​Go Thickness of Aquifer given Discharge for Partially Penetrating Well
H=hw+Qv(log((Rr),e))2πKbG

How to Evaluate Discharge for Fully Penetrating Well given Correction Factor?

Discharge for Fully Penetrating Well given Correction Factor evaluator uses Discharge for Fully Penetrating Gravity Well = Discharge for Partially Penetrating Well/Correction Factor to evaluate the Discharge for Fully Penetrating Gravity Well, Discharge for Fully Penetrating Well given Correction Factor formula is defined as a method to determine the effective discharge of a fully penetrating well in a confined aquifer, taking into account the correction factor that affects the well's discharge rate, which is essential in understanding groundwater flow and management. Discharge for Fully Penetrating Gravity Well is denoted by Qfe symbol.

How to evaluate Discharge for Fully Penetrating Well given Correction Factor using this online evaluator? To use this online evaluator for Discharge for Fully Penetrating Well given Correction Factor, enter Discharge for Partially Penetrating Well (Qv) & Correction Factor (G) and hit the calculate button.

FAQs on Discharge for Fully Penetrating Well given Correction Factor

What is the formula to find Discharge for Fully Penetrating Well given Correction Factor?
The formula of Discharge for Fully Penetrating Well given Correction Factor is expressed as Discharge for Fully Penetrating Gravity Well = Discharge for Partially Penetrating Well/Correction Factor. Here is an example- 6.120482 = 5.08/0.83.
How to calculate Discharge for Fully Penetrating Well given Correction Factor?
With Discharge for Partially Penetrating Well (Qv) & Correction Factor (G) we can find Discharge for Fully Penetrating Well given Correction Factor using the formula - Discharge for Fully Penetrating Gravity Well = Discharge for Partially Penetrating Well/Correction Factor.
Can the Discharge for Fully Penetrating Well given Correction Factor be negative?
No, the Discharge for Fully Penetrating Well given Correction Factor, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Discharge for Fully Penetrating Well given Correction Factor?
Discharge for Fully Penetrating Well given Correction Factor is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge for Fully Penetrating Well given Correction Factor can be measured.
Copied!