Fx Copy
LaTeX Copy
Discharge entering Basin given Settling Velocity is the volumetric flow rate of water that enters a sedimentation basin, calculated based on the settling velocity. Check FAQs
Qs=(vswL)
Qs - Discharge entering Basin given Settling Velocity?vs - Settling Velocity?w - Width?L - Length?

Discharge Entering Basin given Settling Velocity Example

With values
With units
Only example

Here is how the Discharge Entering Basin given Settling Velocity equation looks like with Values.

Here is how the Discharge Entering Basin given Settling Velocity equation looks like with Units.

Here is how the Discharge Entering Basin given Settling Velocity equation looks like.

10.3394Edit=(1.5Edit2.29Edit3.01Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Discharge Entering Basin given Settling Velocity

Discharge Entering Basin given Settling Velocity Solution

Follow our step by step solution on how to calculate Discharge Entering Basin given Settling Velocity?

FIRST Step Consider the formula
Qs=(vswL)
Next Step Substitute values of Variables
Qs=(1.5m/s2.29m3.01m)
Next Step Prepare to Evaluate
Qs=(1.52.293.01)
Next Step Evaluate
Qs=10.33935m³/s
LAST Step Rounding Answer
Qs=10.3394m³/s

Discharge Entering Basin given Settling Velocity Formula Elements

Variables
Discharge entering Basin given Settling Velocity
Discharge entering Basin given Settling Velocity is the volumetric flow rate of water that enters a sedimentation basin, calculated based on the settling velocity.
Symbol: Qs
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Settling Velocity
Settling Velocity is defined as the terminal velocity of a particle in still fluid.
Symbol: vs
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Width
Width is the horizontal measurement or dimension of a structure, feature, or area.
Symbol: w
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Length
Length is the measurement or extent of something from end to end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Discharge entering Basin given Settling Velocity

​Go Discharge given Settling Velocity of Particular Sized Particle
Qs=100vswL70

Other formulas in Discharge in Tank category

​Go Discharge Entering Basin given Flow Velocity
Qv=(Vfwd)
​Go Discharge Entering Basin given Cross-section Area of Tank
Qa=VfAcs
​Go Discharge given Plan Area
Q=vsSABase
​Go Discharge given Height to Length Ratio
Q=vswdHL

How to Evaluate Discharge Entering Basin given Settling Velocity?

Discharge Entering Basin given Settling Velocity evaluator uses Discharge entering Basin given Settling Velocity = (Settling Velocity*Width*Length) to evaluate the Discharge entering Basin given Settling Velocity, The Discharge Entering Basin given Settling Velocity formula is defined as the calculation of the volumetric flow rate of fluid (usually water) entering a basin or tank, based on the settling velocity. Discharge entering Basin given Settling Velocity is denoted by Qs symbol.

How to evaluate Discharge Entering Basin given Settling Velocity using this online evaluator? To use this online evaluator for Discharge Entering Basin given Settling Velocity, enter Settling Velocity (vs), Width (w) & Length (L) and hit the calculate button.

FAQs on Discharge Entering Basin given Settling Velocity

What is the formula to find Discharge Entering Basin given Settling Velocity?
The formula of Discharge Entering Basin given Settling Velocity is expressed as Discharge entering Basin given Settling Velocity = (Settling Velocity*Width*Length). Here is an example- 10.33935 = (1.5*2.29*3.01).
How to calculate Discharge Entering Basin given Settling Velocity?
With Settling Velocity (vs), Width (w) & Length (L) we can find Discharge Entering Basin given Settling Velocity using the formula - Discharge entering Basin given Settling Velocity = (Settling Velocity*Width*Length).
What are the other ways to Calculate Discharge entering Basin given Settling Velocity?
Here are the different ways to Calculate Discharge entering Basin given Settling Velocity-
  • Discharge entering Basin given Settling Velocity=(100*Settling Velocity*Width*Length)/70OpenImg
Can the Discharge Entering Basin given Settling Velocity be negative?
No, the Discharge Entering Basin given Settling Velocity, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Discharge Entering Basin given Settling Velocity?
Discharge Entering Basin given Settling Velocity is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Discharge Entering Basin given Settling Velocity can be measured.
Copied!