Difference in pressure head for light liquid in manometer Formula

Fx Copy
LaTeX Copy
Difference in Pressure Head for Light Liquid in Manometer is the difference in the height of the pressure columns of the manometer for light liquid. Check FAQs
hl=z'(1-(SlSo))
hl - Difference in Pressure Head for Light Liquid?z' - Difference in Liquid Level in Manometer?Sl - Specific Gravity of Lighter Liquid?So - Specific Gravity of Flowing Liquid?

Difference in pressure head for light liquid in manometer Example

With values
With units
Only example

Here is how the Difference in pressure head for light liquid in manometer equation looks like with Values.

Here is how the Difference in pressure head for light liquid in manometer equation looks like with Units.

Here is how the Difference in pressure head for light liquid in manometer equation looks like.

6.0772Edit=19.8Edit(1-(0.7Edit1.01Edit))
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Fluid Mechanics » fx Difference in pressure head for light liquid in manometer

Difference in pressure head for light liquid in manometer Solution

Follow our step by step solution on how to calculate Difference in pressure head for light liquid in manometer?

FIRST Step Consider the formula
hl=z'(1-(SlSo))
Next Step Substitute values of Variables
hl=19.8cm(1-(0.71.01))
Next Step Convert Units
hl=0.198m(1-(0.71.01))
Next Step Prepare to Evaluate
hl=0.198(1-(0.71.01))
Next Step Evaluate
hl=0.0607722772277228m
Next Step Convert to Output's Unit
hl=6.07722772277228cm
LAST Step Rounding Answer
hl=6.0772cm

Difference in pressure head for light liquid in manometer Formula Elements

Variables
Difference in Pressure Head for Light Liquid
Difference in Pressure Head for Light Liquid in Manometer is the difference in the height of the pressure columns of the manometer for light liquid.
Symbol: hl
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Difference in Liquid Level in Manometer
Difference in Liquid Level in Manometer is the difference in the height of the liquid columns of the manometer.
Symbol: z'
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Specific Gravity of Lighter Liquid
The Specific Gravity of Lighter Liquid is the specific weight of the lighter of the two liquids considered in the manometer.
Symbol: Sl
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Specific Gravity of Flowing Liquid
The Specific Gravity of Flowing Liquid is the weight of the liquid per unit volume flowing through the manometer pipe.
Symbol: So
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Kinematics of Flow category

​Go Rate of flow or discharge
Q=Acsvavg
​Go Resultant velocity for two velocity components
V=(u2)+(v2)
​Go Depth of Parabola formed at Free Surface of Water
Z=(ω2)(r12)29.81
​Go Angular Velocity of Vortex using Depth of Parabola
ω=Z29.81r12

How to Evaluate Difference in pressure head for light liquid in manometer?

Difference in pressure head for light liquid in manometer evaluator uses Difference in Pressure Head for Light Liquid = Difference in Liquid Level in Manometer*(1-(Specific Gravity of Lighter Liquid/Specific Gravity of Flowing Liquid)) to evaluate the Difference in Pressure Head for Light Liquid, The Difference in pressure head for light liquid in manometer formula is known while considering the specific gravity of the light liquid, the specific gravity of liquid flowing through a pipe, and the difference of heavier liquid column in U-tube. Difference in Pressure Head for Light Liquid is denoted by hl symbol.

How to evaluate Difference in pressure head for light liquid in manometer using this online evaluator? To use this online evaluator for Difference in pressure head for light liquid in manometer, enter Difference in Liquid Level in Manometer (z'), Specific Gravity of Lighter Liquid (Sl) & Specific Gravity of Flowing Liquid (So) and hit the calculate button.

FAQs on Difference in pressure head for light liquid in manometer

What is the formula to find Difference in pressure head for light liquid in manometer?
The formula of Difference in pressure head for light liquid in manometer is expressed as Difference in Pressure Head for Light Liquid = Difference in Liquid Level in Manometer*(1-(Specific Gravity of Lighter Liquid/Specific Gravity of Flowing Liquid)). Here is an example- 607.7228 = 0.198*(1-(0.7/1.01)).
How to calculate Difference in pressure head for light liquid in manometer?
With Difference in Liquid Level in Manometer (z'), Specific Gravity of Lighter Liquid (Sl) & Specific Gravity of Flowing Liquid (So) we can find Difference in pressure head for light liquid in manometer using the formula - Difference in Pressure Head for Light Liquid = Difference in Liquid Level in Manometer*(1-(Specific Gravity of Lighter Liquid/Specific Gravity of Flowing Liquid)).
Can the Difference in pressure head for light liquid in manometer be negative?
No, the Difference in pressure head for light liquid in manometer, measured in Length cannot be negative.
Which unit is used to measure Difference in pressure head for light liquid in manometer?
Difference in pressure head for light liquid in manometer is usually measured using the Centimeter[cm] for Length. Meter[cm], Millimeter[cm], Kilometer[cm] are the few other units in which Difference in pressure head for light liquid in manometer can be measured.
Copied!