Diameter of rivet given safe tensile load that plate can withstand Formula

Fx Copy
LaTeX Copy
Rivet Diameter is offered from 1/16-inch (1.6 mm) to 3/8-inch (9.5 mm) in diameter (other sizes are considered highly special) and can be up to 8 inches (203 mm) long. Check FAQs
Drivet=p-(Ploadσttplate)
Drivet - Rivet Diameter?p - Pitch of Rivet?Pload - Tensile Load?σt - Tensile Stress?tplate - Thickness of Plate?

Diameter of rivet given safe tensile load that plate can withstand Example

With values
With units
Only example

Here is how the Diameter of rivet given safe tensile load that plate can withstand equation looks like with Values.

Here is how the Diameter of rivet given safe tensile load that plate can withstand equation looks like with Units.

Here is how the Diameter of rivet given safe tensile load that plate can withstand equation looks like.

14.2197Edit=20Edit-(0.012Edit0.173Edit12Edit)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Strength of Materials » fx Diameter of rivet given safe tensile load that plate can withstand

Diameter of rivet given safe tensile load that plate can withstand Solution

Follow our step by step solution on how to calculate Diameter of rivet given safe tensile load that plate can withstand?

FIRST Step Consider the formula
Drivet=p-(Ploadσttplate)
Next Step Substitute values of Variables
Drivet=20mm-(0.012kN0.173MPa12mm)
Next Step Convert Units
Drivet=0.02m-(12N173000Pa0.012m)
Next Step Prepare to Evaluate
Drivet=0.02-(121730000.012)
Next Step Evaluate
Drivet=0.0142196531791908m
Next Step Convert to Output's Unit
Drivet=14.2196531791908mm
LAST Step Rounding Answer
Drivet=14.2197mm

Diameter of rivet given safe tensile load that plate can withstand Formula Elements

Variables
Rivet Diameter
Rivet Diameter is offered from 1/16-inch (1.6 mm) to 3/8-inch (9.5 mm) in diameter (other sizes are considered highly special) and can be up to 8 inches (203 mm) long.
Symbol: Drivet
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Pitch of Rivet
Pitch of Rivet is defined as the distance between the centers of adjacent rivets that hold together the parts of a built member.
Symbol: p
Measurement: LengthUnit: mm
Note: Value can be positive or negative.
Tensile Load
Tensile Load is the stretching force acting on the material and generally results in tensile stress and tensile strain in the specimen.
Symbol: Pload
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
Tensile Stress
Tensile stress can be defined as the magnitude of force applied along an elastic rod, which is divided by the cross-sectional area of the rod in a direction perpendicular to the applied force.
Symbol: σt
Measurement: PressureUnit: MPa
Note: Value should be greater than 0.
Thickness of Plate
The thickness of plate is the state or quality of being thick. The measure of the smallest dimension of a solid figure: a board of two-inch thickness.
Symbol: tplate
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other formulas in Failure Due to Tearing of the Plate Between Rivets of a Row category

​Go Safe tensile load that plate can withstand given area of plate
Pload=σtAb
​Go Safe tensile stress given area of base plate and tensile load
σt=PloadAb
​Go Area of plate for given safe tensile load that plate can withstand
Ab=Ploadσt
​Go Safe tensile load that plate can withstand
Pload=σt(p-Drivet)tplate

How to Evaluate Diameter of rivet given safe tensile load that plate can withstand?

Diameter of rivet given safe tensile load that plate can withstand evaluator uses Rivet Diameter = Pitch of Rivet-(Tensile Load/(Tensile Stress*Thickness of Plate)) to evaluate the Rivet Diameter, The Diameter of rivet given safe tensile load that plate can withstand formula is defined as a chord that runs through the center point of the rivet. It is the longest possible chord of any rivet. The center of a rivet is the midpoint of its diameter. Rivet Diameter is denoted by Drivet symbol.

How to evaluate Diameter of rivet given safe tensile load that plate can withstand using this online evaluator? To use this online evaluator for Diameter of rivet given safe tensile load that plate can withstand, enter Pitch of Rivet (p), Tensile Load (Pload), Tensile Stress t) & Thickness of Plate (tplate) and hit the calculate button.

FAQs on Diameter of rivet given safe tensile load that plate can withstand

What is the formula to find Diameter of rivet given safe tensile load that plate can withstand?
The formula of Diameter of rivet given safe tensile load that plate can withstand is expressed as Rivet Diameter = Pitch of Rivet-(Tensile Load/(Tensile Stress*Thickness of Plate)). Here is an example- -4609094.412331 = 0.02-(12/(173000*0.012)).
How to calculate Diameter of rivet given safe tensile load that plate can withstand?
With Pitch of Rivet (p), Tensile Load (Pload), Tensile Stress t) & Thickness of Plate (tplate) we can find Diameter of rivet given safe tensile load that plate can withstand using the formula - Rivet Diameter = Pitch of Rivet-(Tensile Load/(Tensile Stress*Thickness of Plate)).
Can the Diameter of rivet given safe tensile load that plate can withstand be negative?
No, the Diameter of rivet given safe tensile load that plate can withstand, measured in Length cannot be negative.
Which unit is used to measure Diameter of rivet given safe tensile load that plate can withstand?
Diameter of rivet given safe tensile load that plate can withstand is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Diameter of rivet given safe tensile load that plate can withstand can be measured.
Copied!