Detention Time is the length of time the water is retained in a vessel or basin. Check FAQs
Td=((D)2)((0.011D)+(0.785d)Qd)
Td - Detention Time?D - Diameter?d - Depth?Qd - Discharge in Tank?

Detention Time for Circular Tank Example

With values
With units
Only example

Here is how the Detention Time for Circular Tank equation looks like with Values.

Here is how the Detention Time for Circular Tank equation looks like with Units.

Here is how the Detention Time for Circular Tank equation looks like.

6.7653Edit=((4.8Edit)2)((0.0114.8Edit)+(0.7853Edit)8.2Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Detention Time for Circular Tank

Detention Time for Circular Tank Solution

Follow our step by step solution on how to calculate Detention Time for Circular Tank?

FIRST Step Consider the formula
Td=((D)2)((0.011D)+(0.785d)Qd)
Next Step Substitute values of Variables
Td=((4.8m)2)((0.0114.8m)+(0.7853m)8.2m³/s)
Next Step Prepare to Evaluate
Td=((4.8)2)((0.0114.8)+(0.7853)8.2)
Next Step Evaluate
Td=6.76533073170732s
LAST Step Rounding Answer
Td=6.7653s

Detention Time for Circular Tank Formula Elements

Variables
Detention Time
Detention Time is the length of time the water is retained in a vessel or basin.
Symbol: Td
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Diameter
Diameter is the straight-line distance passing through the center of a circular cross-section, connecting two points on its boundary.
Symbol: D
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Depth
Depth is the vertical distance from the surface of a reference point, such as the ground or water surface, to a specific point or feature below.
Symbol: d
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Discharge in Tank
Discharge in Tank is the volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material.
Symbol: Qd
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other Formulas to find Detention Time

​Go Detention Time for Rectangular Tank
Td=VQd
​Go Detention Time given Discharge
Td=(wLdQ)

Other formulas in Important Formulas of Design of Continuous Flow Type of Sedimentation Tank category

​Go Overflow Rate given Discharge
SOR=QwL
​Go Rate of Flow given Detention Time
qflow=(VTd)
​Go Volume of Tank given Detention Time
V=Tdqflow
​Go Cross-section Area of Tank with known Velocity of Flow of Water
Acs=QVw

How to Evaluate Detention Time for Circular Tank?

Detention Time for Circular Tank evaluator uses Detention Time = ((Diameter)^2)*(((0.011*Diameter)+(0.785*Depth))/Discharge in Tank) to evaluate the Detention Time, The Detention Time for Circular Tank formula is defined as theoretical time required for given amount of water or wastewater to pass through tank at given rate of flow. Detention Time is denoted by Td symbol.

How to evaluate Detention Time for Circular Tank using this online evaluator? To use this online evaluator for Detention Time for Circular Tank, enter Diameter (D), Depth (d) & Discharge in Tank (Qd) and hit the calculate button.

FAQs on Detention Time for Circular Tank

What is the formula to find Detention Time for Circular Tank?
The formula of Detention Time for Circular Tank is expressed as Detention Time = ((Diameter)^2)*(((0.011*Diameter)+(0.785*Depth))/Discharge in Tank). Here is an example- 6.765331 = ((4.8)^2)*(((0.011*4.8)+(0.785*3))/8.2).
How to calculate Detention Time for Circular Tank?
With Diameter (D), Depth (d) & Discharge in Tank (Qd) we can find Detention Time for Circular Tank using the formula - Detention Time = ((Diameter)^2)*(((0.011*Diameter)+(0.785*Depth))/Discharge in Tank).
What are the other ways to Calculate Detention Time?
Here are the different ways to Calculate Detention Time-
  • Detention Time=Volume of Tank/Discharge in TankOpenImg
  • Detention Time=((Width*Length*Depth)/Discharge)OpenImg
Can the Detention Time for Circular Tank be negative?
No, the Detention Time for Circular Tank, measured in Time cannot be negative.
Which unit is used to measure Detention Time for Circular Tank?
Detention Time for Circular Tank is usually measured using the Second[s] for Time. Millisecond[s], Microsecond[s], Nanosecond[s] are the few other units in which Detention Time for Circular Tank can be measured.
Copied!