Design Surface Loading Rate given Surface Area of Circular Settling Tank Formula

Fx Copy
LaTeX Copy
Surface Loading Rate is the volume of liquid applied per unit surface area of a treatment process, such as a clarifier. Check FAQs
Sl=(QpSA)
Sl - Surface Loading Rate?Qp - Peak Discharge?SA - Surface Area?

Design Surface Loading Rate given Surface Area of Circular Settling Tank Example

With values
With units
Only example

Here is how the Design Surface Loading Rate given Surface Area of Circular Settling Tank equation looks like with Values.

Here is how the Design Surface Loading Rate given Surface Area of Circular Settling Tank equation looks like with Units.

Here is how the Design Surface Loading Rate given Surface Area of Circular Settling Tank equation looks like.

0.1085Edit=(37.5Edit4Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Design Surface Loading Rate given Surface Area of Circular Settling Tank

Design Surface Loading Rate given Surface Area of Circular Settling Tank Solution

Follow our step by step solution on how to calculate Design Surface Loading Rate given Surface Area of Circular Settling Tank?

FIRST Step Consider the formula
Sl=(QpSA)
Next Step Substitute values of Variables
Sl=(37.5MLD4)
Next Step Convert Units
Sl=(0.434m³/s4)
Next Step Prepare to Evaluate
Sl=(0.4344)
Next Step Evaluate
Sl=0.108506944444445kg/s*m²
LAST Step Rounding Answer
Sl=0.1085kg/s*m²

Design Surface Loading Rate given Surface Area of Circular Settling Tank Formula Elements

Variables
Surface Loading Rate
Surface Loading Rate is the volume of liquid applied per unit surface area of a treatment process, such as a clarifier.
Symbol: Sl
Measurement: Solid Loading RateUnit: kg/s*m²
Note: Value should be greater than 0.
Peak Discharge
Peak Discharge is the maximum volume flow rate passing a particular location during an event.
Symbol: Qp
Measurement: Volumetric Flow RateUnit: MLD
Note: Value can be positive or negative.
Surface Area
Surface Area is the horizontal area available for sedimentation, impacting the tank's capacity to separate solids, typically measured in square meters (m²).
Symbol: SA
Measurement: AreaUnit:
Note: Value should be greater than 0.

Other formulas in Design of a Circular Settling Tank category

​Go Surface Area of Circular Settling Tank
SA=(QpSl)
​Go Peak Discharge given Surface Area of Circular Settling Tank
Qp=(SASl)
​Go Peak Discharge in Circular Settling Tanks
Qp=Qdf
​Go Average Daily Load using Peak Discharge in Circular Settling Tanks
Qd=(Qpf)

How to Evaluate Design Surface Loading Rate given Surface Area of Circular Settling Tank?

Design Surface Loading Rate given Surface Area of Circular Settling Tank evaluator uses Surface Loading Rate = (Peak Discharge/Surface Area) to evaluate the Surface Loading Rate, The Design Surface Loading Rate given Surface Area of Circular Settling Tank is defined as rate at which wastewater can be applied to the surface area of the circular settling tank, typically expressed in units such as (L/s/m²) or (m³/h/m²), based on the tank's design specifications and hydraulic capacity. Surface Loading Rate is denoted by Sl symbol.

How to evaluate Design Surface Loading Rate given Surface Area of Circular Settling Tank using this online evaluator? To use this online evaluator for Design Surface Loading Rate given Surface Area of Circular Settling Tank, enter Peak Discharge (Qp) & Surface Area (SA) and hit the calculate button.

FAQs on Design Surface Loading Rate given Surface Area of Circular Settling Tank

What is the formula to find Design Surface Loading Rate given Surface Area of Circular Settling Tank?
The formula of Design Surface Loading Rate given Surface Area of Circular Settling Tank is expressed as Surface Loading Rate = (Peak Discharge/Surface Area). Here is an example- 0.108507 = (0.434027777777778/4).
How to calculate Design Surface Loading Rate given Surface Area of Circular Settling Tank?
With Peak Discharge (Qp) & Surface Area (SA) we can find Design Surface Loading Rate given Surface Area of Circular Settling Tank using the formula - Surface Loading Rate = (Peak Discharge/Surface Area).
Can the Design Surface Loading Rate given Surface Area of Circular Settling Tank be negative?
No, the Design Surface Loading Rate given Surface Area of Circular Settling Tank, measured in Solid Loading Rate cannot be negative.
Which unit is used to measure Design Surface Loading Rate given Surface Area of Circular Settling Tank?
Design Surface Loading Rate given Surface Area of Circular Settling Tank is usually measured using the Kilogram per Second Square Meter[kg/s*m²] for Solid Loading Rate. Kilogram per Second Square Decameter[kg/s*m²], Kilogram per Second Are[kg/s*m²], kilogram per Day Square Meter[kg/s*m²] are the few other units in which Design Surface Loading Rate given Surface Area of Circular Settling Tank can be measured.
Copied!