Fx Copy
LaTeX Copy
Depth of Water is the depth in the well measured above the impermeable layer. Check FAQs
hw=H-(Qtlog(R2rB,e)2πKb)
hw - Depth of Water?H - Initial Piezometric Surface?Qt - Discharge by Each Well when Two Well Interference?R - Radius of Influence?r - Radius of Well?B - Distance Between Wells?K - Coefficient of Permeability?b - Aquifer Thickness?π - Archimedes' constant?

Depth of Water in Well when Interference among Well is Present Example

With values
With units
Only example

Here is how the Depth of Water in Well when Interference among Well is Present equation looks like with Values.

Here is how the Depth of Water in Well when Interference among Well is Present equation looks like with Units.

Here is how the Depth of Water in Well when Interference among Well is Present equation looks like.

2.4445Edit=20Edit-(12.26Editlog(100Edit22.94Edit2.93Edit,e)23.14160.105Edit15Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Depth of Water in Well when Interference among Well is Present

Depth of Water in Well when Interference among Well is Present Solution

Follow our step by step solution on how to calculate Depth of Water in Well when Interference among Well is Present?

FIRST Step Consider the formula
hw=H-(Qtlog(R2rB,e)2πKb)
Next Step Substitute values of Variables
hw=20m-(12.26m³/slog(100m22.94m2.93m,e)2π0.105cm/s15m)
Next Step Substitute values of Constants
hw=20m-(12.26m³/slog(100m22.94m2.93m,e)23.14160.105cm/s15m)
Next Step Convert Units
hw=20m-(12.26m³/slog(100m22.94m2.93m,e)23.14160.001m/s15m)
Next Step Prepare to Evaluate
hw=20-(12.26log(10022.942.93,e)23.14160.00115)
Next Step Evaluate
hw=2.44445426331082m
LAST Step Rounding Answer
hw=2.4445m

Depth of Water in Well when Interference among Well is Present Formula Elements

Variables
Constants
Functions
Depth of Water
Depth of Water is the depth in the well measured above the impermeable layer.
Symbol: hw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Initial Piezometric Surface
The initial piezometric surface refers to the level at which groundwater naturally stands in a confined aquifer before any pumping or external influence.
Symbol: H
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge by Each Well when Two Well Interference
Discharge by Each Well when Two Well Interference is the sum of the individual well rates, adjusted for interference.
Symbol: Qt
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Radius of Influence
The radius of influence is the distance from a pumping well to the point where the drawdown, or lowering of the water table, becomes negligible.
Symbol: R
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Well
The radius of well refers to the horizontal distance from the center of the well to its inner wall, essentially the well’s radius.
Symbol: r
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Distance Between Wells
Distance Between Wells refers to the center to center distance between the well.
Symbol: B
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Coefficient of Permeability
Coefficient of Permeability refers to the ease with which water can flow through the aquifer's pore spaces.
Symbol: K
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Aquifer Thickness
Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Symbol: b
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Depth of Water

​Go Depth of Water in Well when Interference among Three Well is Present
hw=H-(Qthlog(R3rB2,e)2πKb)

Other formulas in Interference Among Wells category

​Go Discharge through Each Well when Interference among Well is Present
Qt=2πKb(H-hw)log(R2rB,e)
​Go Coefficient of Permeability when Interference among Well is Present
K=Qtlog(R2rB,e)2πb(H-hw)

How to Evaluate Depth of Water in Well when Interference among Well is Present?

Depth of Water in Well when Interference among Well is Present evaluator uses Depth of Water = Initial Piezometric Surface-((Discharge by Each Well when Two Well Interference*log((Radius of Influence^2)/(Radius of Well*Distance Between Wells),e))/(2*pi*Coefficient of Permeability*Aquifer Thickness)) to evaluate the Depth of Water, Depth of Water in Well when Interference among Well is Present formula is defined as the vertical distance from the ground surface to the water level in a well, considering the interference effects from nearby wells on the water flow. It's an important parameter in well hydraulics, helping to determine the well's yield and overall performance. Depth of Water is denoted by hw symbol.

How to evaluate Depth of Water in Well when Interference among Well is Present using this online evaluator? To use this online evaluator for Depth of Water in Well when Interference among Well is Present, enter Initial Piezometric Surface (H), Discharge by Each Well when Two Well Interference (Qt), Radius of Influence (R), Radius of Well (r), Distance Between Wells (B), Coefficient of Permeability (K) & Aquifer Thickness (b) and hit the calculate button.

FAQs on Depth of Water in Well when Interference among Well is Present

What is the formula to find Depth of Water in Well when Interference among Well is Present?
The formula of Depth of Water in Well when Interference among Well is Present is expressed as Depth of Water = Initial Piezometric Surface-((Discharge by Each Well when Two Well Interference*log((Radius of Influence^2)/(Radius of Well*Distance Between Wells),e))/(2*pi*Coefficient of Permeability*Aquifer Thickness)). Here is an example- 2.444454 = 20-((12.26*log((100^2)/(2.94*2.93),e))/(2*pi*0.00105*15)).
How to calculate Depth of Water in Well when Interference among Well is Present?
With Initial Piezometric Surface (H), Discharge by Each Well when Two Well Interference (Qt), Radius of Influence (R), Radius of Well (r), Distance Between Wells (B), Coefficient of Permeability (K) & Aquifer Thickness (b) we can find Depth of Water in Well when Interference among Well is Present using the formula - Depth of Water = Initial Piezometric Surface-((Discharge by Each Well when Two Well Interference*log((Radius of Influence^2)/(Radius of Well*Distance Between Wells),e))/(2*pi*Coefficient of Permeability*Aquifer Thickness)). This formula also uses Archimedes' constant and Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Depth of Water?
Here are the different ways to Calculate Depth of Water-
  • Depth of Water=Initial Piezometric Surface-((Discharge by Each Well at Three Well Interference*log((Radius of Influence^3)/(Radius of Well*Distance Between Wells^2),e))/(2*pi*Coefficient of Permeability*Aquifer Thickness))OpenImg
Can the Depth of Water in Well when Interference among Well is Present be negative?
No, the Depth of Water in Well when Interference among Well is Present, measured in Length cannot be negative.
Which unit is used to measure Depth of Water in Well when Interference among Well is Present?
Depth of Water in Well when Interference among Well is Present is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Depth of Water in Well when Interference among Well is Present can be measured.
Copied!