Fx Copy
LaTeX Copy
Depth of Water in Well is measured above the impermeable layer. Check FAQs
hwell=bw-(Qlog((Rwr),10)2.72Tenvi)
hwell - Depth of Water in Well?bw - Aquifer Thickness?Q - Discharge?Rw - Radius of Influence?r - Radius of Well?Tenvi - Coefficient of Transmissibility?

Depth of Water in Well given Coefficient of Transmissibility with Base 10 Example

With values
With units
Only example

Here is how the Depth of Water in Well given Coefficient of Transmissibility with Base 10 equation looks like with Values.

Here is how the Depth of Water in Well given Coefficient of Transmissibility with Base 10 equation looks like with Units.

Here is how the Depth of Water in Well given Coefficient of Transmissibility with Base 10 equation looks like.

9.9851Edit=14.15Edit-(1.01Editlog((8.6Edit7.5Edit),10)2.721.5Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Depth of Water in Well given Coefficient of Transmissibility with Base 10

Depth of Water in Well given Coefficient of Transmissibility with Base 10 Solution

Follow our step by step solution on how to calculate Depth of Water in Well given Coefficient of Transmissibility with Base 10?

FIRST Step Consider the formula
hwell=bw-(Qlog((Rwr),10)2.72Tenvi)
Next Step Substitute values of Variables
hwell=14.15m-(1.01m³/slog((8.6m7.5m),10)2.721.5m²/s)
Next Step Prepare to Evaluate
hwell=14.15-(1.01log((8.67.5),10)2.721.5)
Next Step Evaluate
hwell=9.98511554710837m
LAST Step Rounding Answer
hwell=9.9851m

Depth of Water in Well given Coefficient of Transmissibility with Base 10 Formula Elements

Variables
Functions
Depth of Water in Well
Depth of Water in Well is measured above the impermeable layer.
Symbol: hwell
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Aquifer Thickness
Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Symbol: bw
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Radius of Influence
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Symbol: Rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Well
Radius of Well is defined as the distance from center of well to its outer boundary.
Symbol: r
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Coefficient of Transmissibility
Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Symbol: Tenvi
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Depth of Water in Well

​Go Depth of Water in Well given Discharge in Confined Aquifer
hwell=bw-(Qlog((Rwr),e)2πKWHbp)
​Go Depth of Water in Well given Discharge in Confined Aquifer with Base 10
hwell=bw-(Qlog((Rwr),10)2.72Kwbp)

Other formulas in Depth of Water in Well category

​Go Depth of Water in Well given Coefficient of Transmissibility
hw=Hi-(Qlog((Rwr),e)2πTenvi)
​Go Depth of Water in 1st Well given Confined Aquifer Discharge
h1=h2-(Qlog((r2r1),10)2.72KWHbp)
​Go Depth of Water in 2nd Well given Confined Aquifer Discharge
h2=h1+(Qlog((r2r1),10)2.72KWHbp)
​Go Depth of Water in 1st Well given Coefficient of Transmissibility
h1=h2-(Qlog((r2r1),10)2.72Tenvi)

How to Evaluate Depth of Water in Well given Coefficient of Transmissibility with Base 10?

Depth of Water in Well given Coefficient of Transmissibility with Base 10 evaluator uses Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of Well),10))/(2.72*Coefficient of Transmissibility)) to evaluate the Depth of Water in Well, The Depth of Water in Well given Coefficient of Transmissibility with Base 10 formula is defined as the value of depth of water in well with base 10, when we have prior information of coefficient of transmissibility. Depth of Water in Well is denoted by hwell symbol.

How to evaluate Depth of Water in Well given Coefficient of Transmissibility with Base 10 using this online evaluator? To use this online evaluator for Depth of Water in Well given Coefficient of Transmissibility with Base 10, enter Aquifer Thickness (bw), Discharge (Q), Radius of Influence (Rw), Radius of Well (r) & Coefficient of Transmissibility (Tenvi) and hit the calculate button.

FAQs on Depth of Water in Well given Coefficient of Transmissibility with Base 10

What is the formula to find Depth of Water in Well given Coefficient of Transmissibility with Base 10?
The formula of Depth of Water in Well given Coefficient of Transmissibility with Base 10 is expressed as Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of Well),10))/(2.72*Coefficient of Transmissibility)). Here is an example- 10.83512 = 14.15-((1.01*log((8.6/7.5),10))/(2.72*1.5)).
How to calculate Depth of Water in Well given Coefficient of Transmissibility with Base 10?
With Aquifer Thickness (bw), Discharge (Q), Radius of Influence (Rw), Radius of Well (r) & Coefficient of Transmissibility (Tenvi) we can find Depth of Water in Well given Coefficient of Transmissibility with Base 10 using the formula - Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of Well),10))/(2.72*Coefficient of Transmissibility)). This formula also uses Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Depth of Water in Well?
Here are the different ways to Calculate Depth of Water in Well-
  • Depth of Water in Well=Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of Well),e))/(2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping))OpenImg
  • Depth of Water in Well=Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of Well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness During Pumping))OpenImg
Can the Depth of Water in Well given Coefficient of Transmissibility with Base 10 be negative?
Yes, the Depth of Water in Well given Coefficient of Transmissibility with Base 10, measured in Length can be negative.
Which unit is used to measure Depth of Water in Well given Coefficient of Transmissibility with Base 10?
Depth of Water in Well given Coefficient of Transmissibility with Base 10 is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Depth of Water in Well given Coefficient of Transmissibility with Base 10 can be measured.
Copied!