Fx Copy
LaTeX Copy
Depth of water 2 means the depth of the water in 2nd well. Check FAQs
h2=h1+(Qlog((r2r1),10)2.72Tenvi)
h2 - Depth of Water 2?h1 - Depth of Water 1?Q - Discharge?r2 - Radial Distance at Observation Well 2?r1 - Radial Distance at Observation Well 1?Tenvi - Coefficient of Transmissibility?

Depth of Water in 2nd Well given Coefficient of Transmissibility Example

With values
With units
Only example

Here is how the Depth of Water in 2nd Well given Coefficient of Transmissibility equation looks like with Values.

Here is how the Depth of Water in 2nd Well given Coefficient of Transmissibility equation looks like with Units.

Here is how the Depth of Water in 2nd Well given Coefficient of Transmissibility equation looks like.

18.105Edit=17.85Edit+(1.01Editlog((10Edit1.07Edit),10)2.721.5Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Depth of Water in 2nd Well given Coefficient of Transmissibility

Depth of Water in 2nd Well given Coefficient of Transmissibility Solution

Follow our step by step solution on how to calculate Depth of Water in 2nd Well given Coefficient of Transmissibility?

FIRST Step Consider the formula
h2=h1+(Qlog((r2r1),10)2.72Tenvi)
Next Step Substitute values of Variables
h2=17.85m+(1.01m³/slog((10m1.07m),10)2.721.5m²/s)
Next Step Prepare to Evaluate
h2=17.85+(1.01log((101.07),10)2.721.5)
Next Step Evaluate
h2=18.1050431508526m
LAST Step Rounding Answer
h2=18.105m

Depth of Water in 2nd Well given Coefficient of Transmissibility Formula Elements

Variables
Functions
Depth of Water 2
Depth of water 2 means the depth of the water in 2nd well.
Symbol: h2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Depth of Water 1
Depth of Water 1 is the depth of water in the 1st considered well.
Symbol: h1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Radial Distance at Observation Well 2
Radial Distance at Observation Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used.
Symbol: r2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Radial Distance at Observation Well 1
Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
Symbol: r1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Coefficient of Transmissibility
Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Symbol: Tenvi
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Depth of Water 2

​Go Depth of Water in 2nd Well given Confined Aquifer Discharge
h2=h1+(Qlog((r2r1),10)2.72KWHbp)

Other formulas in Depth of Water in Well category

​Go Depth of Water in Well given Discharge in Confined Aquifer
hwell=bw-(Qlog((Rwr),e)2πKWHbp)
​Go Depth of Water in Well given Discharge in Confined Aquifer with Base 10
hwell=bw-(Qlog((Rwr),10)2.72Kwbp)
​Go Depth of Water in Well given Coefficient of Transmissibility
hw=Hi-(Qlog((Rwr),e)2πTenvi)
​Go Depth of Water in Well given Coefficient of Transmissibility with Base 10
hwell=bw-(Qlog((Rwr),10)2.72Tenvi)

How to Evaluate Depth of Water in 2nd Well given Coefficient of Transmissibility?

Depth of Water in 2nd Well given Coefficient of Transmissibility evaluator uses Depth of Water 2 = Depth of Water 1+((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Coefficient of Transmissibility)) to evaluate the Depth of Water 2, The Depth of Water in 2nd Well given Coefficient of Transmissibility formula is defined as the calculation of depth of water in 2nd well when we have prior information of coefficient of transmissibility. Depth of Water 2 is denoted by h2 symbol.

How to evaluate Depth of Water in 2nd Well given Coefficient of Transmissibility using this online evaluator? To use this online evaluator for Depth of Water in 2nd Well given Coefficient of Transmissibility, enter Depth of Water 1 (h1), Discharge (Q), Radial Distance at Observation Well 2 (r2), Radial Distance at Observation Well 1 (r1) & Coefficient of Transmissibility (Tenvi) and hit the calculate button.

FAQs on Depth of Water in 2nd Well given Coefficient of Transmissibility

What is the formula to find Depth of Water in 2nd Well given Coefficient of Transmissibility?
The formula of Depth of Water in 2nd Well given Coefficient of Transmissibility is expressed as Depth of Water 2 = Depth of Water 1+((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Coefficient of Transmissibility)). Here is an example- 18.10504 = 17.85+((1.01*log((10/1.07),10))/(2.72*1.5)).
How to calculate Depth of Water in 2nd Well given Coefficient of Transmissibility?
With Depth of Water 1 (h1), Discharge (Q), Radial Distance at Observation Well 2 (r2), Radial Distance at Observation Well 1 (r1) & Coefficient of Transmissibility (Tenvi) we can find Depth of Water in 2nd Well given Coefficient of Transmissibility using the formula - Depth of Water 2 = Depth of Water 1+((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Coefficient of Transmissibility)). This formula also uses Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Depth of Water 2?
Here are the different ways to Calculate Depth of Water 2-
  • Depth of Water 2=Depth of Water 1+((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping))OpenImg
Can the Depth of Water in 2nd Well given Coefficient of Transmissibility be negative?
Yes, the Depth of Water in 2nd Well given Coefficient of Transmissibility, measured in Length can be negative.
Which unit is used to measure Depth of Water in 2nd Well given Coefficient of Transmissibility?
Depth of Water in 2nd Well given Coefficient of Transmissibility is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Depth of Water in 2nd Well given Coefficient of Transmissibility can be measured.
Copied!