Depth of Water at Current Meter Location Formula

Fx Copy
LaTeX Copy
Depth of Water at Current Meter Location [length] where current meter is used to measure water velocity at predetermined points. Check FAQs
D=rH(VavgVmeas)32
D - Depth of Water at Current Meter Location?rH - Hydraulic Radius?Vavg - Max Velocity averaged Over Inlet Cross Section?Vmeas - Point Measurement of Maximum Velocity?

Depth of Water at Current Meter Location Example

With values
With units
Only example

Here is how the Depth of Water at Current Meter Location equation looks like with Values.

Here is how the Depth of Water at Current Meter Location equation looks like with Units.

Here is how the Depth of Water at Current Meter Location equation looks like.

8.1011Edit=0.33Edit(3Edit25.34Edit)32
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Coastal and Ocean Engineering » fx Depth of Water at Current Meter Location

Depth of Water at Current Meter Location Solution

Follow our step by step solution on how to calculate Depth of Water at Current Meter Location?

FIRST Step Consider the formula
D=rH(VavgVmeas)32
Next Step Substitute values of Variables
D=0.33m(3m/s25.34m/s)32
Next Step Prepare to Evaluate
D=0.33(325.34)32
Next Step Evaluate
D=8.10106232906936m
LAST Step Rounding Answer
D=8.1011m

Depth of Water at Current Meter Location Formula Elements

Variables
Depth of Water at Current Meter Location
Depth of Water at Current Meter Location [length] where current meter is used to measure water velocity at predetermined points.
Symbol: D
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Hydraulic Radius
The Hydraulic Radius is the ratio of the cross-sectional area of a channel or pipe in which a fluid flows to the conduit's wet perimeter.
Symbol: rH
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Max Velocity averaged Over Inlet Cross Section
Max Velocity averaged Over Inlet Cross Section entirely [length/time] depends on point measurement of maximum velocity, hydraulic radius and depth of water at current meter location.
Symbol: Vavg
Measurement: SpeedUnit: m/s
Note: Value can be positive or negative.
Point Measurement of Maximum Velocity
Point measurement of Maximum Velocity [length/time] depends on max velocity averaged over inlet cross section, hydraulic radius and depth of water at current meter location.
Symbol: Vmeas
Measurement: SpeedUnit: m/s
Note: Value can be positive or negative.

Other formulas in Tidal Prism category

​Go Tidal Prism filling Bay given Maximum Ebb Tide Discharge
P=TQmaxπ
​Go Maximum Instantaneous Ebb Tide Discharge given Tidal Prism
Qmax=PπT
​Go Tidal Period given Maximum Instantaneous Ebb Tide Discharge and Tidal Prism
T=PπQmax
​Go Tidal Prism given Average Area over Channel Length
P=TVmAavgπ

How to Evaluate Depth of Water at Current Meter Location?

Depth of Water at Current Meter Location evaluator uses Depth of Water at Current Meter Location = Hydraulic Radius/(Max Velocity averaged Over Inlet Cross Section/Point Measurement of Maximum Velocity)^(3/2) to evaluate the Depth of Water at Current Meter Location, The Depth of Water at Current Meter Location formula is defined as a water-depth parameter that recommends ways to relate point measurements of maximum velocity in the center of the channel to velocities representative of the entire inlet. Depth of Water at Current Meter Location is denoted by D symbol.

How to evaluate Depth of Water at Current Meter Location using this online evaluator? To use this online evaluator for Depth of Water at Current Meter Location, enter Hydraulic Radius (rH), Max Velocity averaged Over Inlet Cross Section (Vavg) & Point Measurement of Maximum Velocity (Vmeas) and hit the calculate button.

FAQs on Depth of Water at Current Meter Location

What is the formula to find Depth of Water at Current Meter Location?
The formula of Depth of Water at Current Meter Location is expressed as Depth of Water at Current Meter Location = Hydraulic Radius/(Max Velocity averaged Over Inlet Cross Section/Point Measurement of Maximum Velocity)^(3/2). Here is an example- 8.101062 = 0.33/(3/25.34)^(3/2).
How to calculate Depth of Water at Current Meter Location?
With Hydraulic Radius (rH), Max Velocity averaged Over Inlet Cross Section (Vavg) & Point Measurement of Maximum Velocity (Vmeas) we can find Depth of Water at Current Meter Location using the formula - Depth of Water at Current Meter Location = Hydraulic Radius/(Max Velocity averaged Over Inlet Cross Section/Point Measurement of Maximum Velocity)^(3/2).
Can the Depth of Water at Current Meter Location be negative?
No, the Depth of Water at Current Meter Location, measured in Length cannot be negative.
Which unit is used to measure Depth of Water at Current Meter Location?
Depth of Water at Current Meter Location is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Depth of Water at Current Meter Location can be measured.
Copied!