Depth of Reference Filter using Treatability Constant Formula

Fx Copy
LaTeX Copy
The Depth of Reference Filter refers to the standard vertical distance used to compare filtration systems, typically measured in meters (m), to assess relative performance. Check FAQs
D1=D2(K30/25K30/20)1a
D1 - Depth of Reference Filter?D2 - Depth of Actual Filter?K30/25 - Treatability Constant at 30°C and 25ft Depth?K30/20 - Treatability Constant at 30°C and 20ft Depth?a - Empirical Constant?

Depth of Reference Filter using Treatability Constant Example

With values
With units
Only example

Here is how the Depth of Reference Filter using Treatability Constant equation looks like with Values.

Here is how the Depth of Reference Filter using Treatability Constant equation looks like with Units.

Here is how the Depth of Reference Filter using Treatability Constant equation looks like.

6.1052Edit=7.6Edit(26.8Edit28.62Edit)10.3Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Depth of Reference Filter using Treatability Constant

Depth of Reference Filter using Treatability Constant Solution

Follow our step by step solution on how to calculate Depth of Reference Filter using Treatability Constant?

FIRST Step Consider the formula
D1=D2(K30/25K30/20)1a
Next Step Substitute values of Variables
D1=7.6m(26.828.62)10.3
Next Step Prepare to Evaluate
D1=7.6(26.828.62)10.3
Next Step Evaluate
D1=6.1051659627612m
LAST Step Rounding Answer
D1=6.1052m

Depth of Reference Filter using Treatability Constant Formula Elements

Variables
Depth of Reference Filter
The Depth of Reference Filter refers to the standard vertical distance used to compare filtration systems, typically measured in meters (m), to assess relative performance.
Symbol: D1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Depth of Actual Filter
The Depth of Actual Filter refers to the vertical distance from the top surface to the bottom of the filter media, impacting filtration efficiency, typically measured in meters (m).
Symbol: D2
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Treatability Constant at 30°C and 25ft Depth
The Treatability Constant at 30°C and 25ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 25ft filter depth.
Symbol: K30/25
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Treatability Constant at 30°C and 20ft Depth
The Treatability Constant at 30°C and 20ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth.
Symbol: K30/20
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Empirical Constant
The Empirical Constant refers to a value derived from experimental data and observations, used in equations to predict or describe phenomena within specific conditions.
Symbol: a
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Treatability Constant category

​Go Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth
K30/20=K20/20(θ)T-20
​Go Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth
K20/20=K30/20(θ)T-20
​Go Temperature Activity Coefficient given Treatability Constant
θ=(K30/20K20/20)1T-20
​Go Wastewater Temperature using Treatability Constant
T=20+(ln(K30/20K20/20)(1ln(θ)))

How to Evaluate Depth of Reference Filter using Treatability Constant?

Depth of Reference Filter using Treatability Constant evaluator uses Depth of Reference Filter = Depth of Actual Filter*(Treatability Constant at 30°C and 25ft Depth/Treatability Constant at 30°C and 20ft Depth)^(1/Empirical Constant) to evaluate the Depth of Reference Filter, The Depth of Reference Filter using Treatability Constant is defined as the standard vertical distance used for comparison in filtration systems, typically measured in meters (m), to assess relative performance. Depth of Reference Filter is denoted by D1 symbol.

How to evaluate Depth of Reference Filter using Treatability Constant using this online evaluator? To use this online evaluator for Depth of Reference Filter using Treatability Constant, enter Depth of Actual Filter (D2), Treatability Constant at 30°C and 25ft Depth (K30/25), Treatability Constant at 30°C and 20ft Depth (K30/20) & Empirical Constant (a) and hit the calculate button.

FAQs on Depth of Reference Filter using Treatability Constant

What is the formula to find Depth of Reference Filter using Treatability Constant?
The formula of Depth of Reference Filter using Treatability Constant is expressed as Depth of Reference Filter = Depth of Actual Filter*(Treatability Constant at 30°C and 25ft Depth/Treatability Constant at 30°C and 20ft Depth)^(1/Empirical Constant). Here is an example- 6.744225 = 7.6*(26.8/28.62)^(1/0.3).
How to calculate Depth of Reference Filter using Treatability Constant?
With Depth of Actual Filter (D2), Treatability Constant at 30°C and 25ft Depth (K30/25), Treatability Constant at 30°C and 20ft Depth (K30/20) & Empirical Constant (a) we can find Depth of Reference Filter using Treatability Constant using the formula - Depth of Reference Filter = Depth of Actual Filter*(Treatability Constant at 30°C and 25ft Depth/Treatability Constant at 30°C and 20ft Depth)^(1/Empirical Constant).
Can the Depth of Reference Filter using Treatability Constant be negative?
No, the Depth of Reference Filter using Treatability Constant, measured in Length cannot be negative.
Which unit is used to measure Depth of Reference Filter using Treatability Constant?
Depth of Reference Filter using Treatability Constant is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Depth of Reference Filter using Treatability Constant can be measured.
Copied!