Fx Copy
LaTeX Copy
Depth of Flow is the distance from the top or surface of the flow to the bottom of a channel or other waterway or Depth of Flow at the Vertical while measuring Sound Weights. Check FAQs
df=(Qe2.264Wt)23
df - Depth of Flow?Qe - Environmental Discharge?Wt - Width of Throat?

Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge Example

With values
With units
Only example

Here is how the Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge equation looks like with Values.

Here is how the Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge equation looks like with Units.

Here is how the Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge equation looks like.

3.2514Edit=(39.82Edit2.2643Edit)23
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge

Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge Solution

Follow our step by step solution on how to calculate Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge?

FIRST Step Consider the formula
df=(Qe2.264Wt)23
Next Step Substitute values of Variables
df=(39.82m³/s2.2643m)23
Next Step Prepare to Evaluate
df=(39.822.2643)23
Next Step Evaluate
df=3.25138989986678m
LAST Step Rounding Answer
df=3.2514m

Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge Formula Elements

Variables
Depth of Flow
Depth of Flow is the distance from the top or surface of the flow to the bottom of a channel or other waterway or Depth of Flow at the Vertical while measuring Sound Weights.
Symbol: df
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Environmental Discharge
Environmental Discharge is the rate of flow of a liquid.
Symbol: Qe
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Width of Throat
Width of Throat is the narrowest section of a conduit or channel, such as in a venturi meter or flume.
Symbol: Wt
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Depth of Flow

​Go Depth of Parshall Flume given Discharge
df=(Qec)1np

Other formulas in Parshall Flume category

​Go Discharge Passing through Parshall Flume
Qe=(2.264Wt(df)32)
​Go Width of Throat given Discharge
Wt=Qe2.264(df)32
​Go Depth of Parshall Flume given Width
dpf=(cw)1CD-1
​Go Width of Parshall Flume given Depth
wp=(d)CD-1c

How to Evaluate Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge?

Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge evaluator uses Depth of Flow = (Environmental Discharge/(2.264*Width of Throat))^(2/3) to evaluate the Depth of Flow, The Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge formula is defined as the distance from the top or surface of the flow to the bottom of a channel when we have prior information of other parameters. Depth of Flow is denoted by df symbol.

How to evaluate Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge using this online evaluator? To use this online evaluator for Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge, enter Environmental Discharge (Qe) & Width of Throat (Wt) and hit the calculate button.

FAQs on Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge

What is the formula to find Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge?
The formula of Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge is expressed as Depth of Flow = (Environmental Discharge/(2.264*Width of Throat))^(2/3). Here is an example- 3.261181 = (39.82/(2.264*3))^(2/3).
How to calculate Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge?
With Environmental Discharge (Qe) & Width of Throat (Wt) we can find Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge using the formula - Depth of Flow = (Environmental Discharge/(2.264*Width of Throat))^(2/3).
What are the other ways to Calculate Depth of Flow?
Here are the different ways to Calculate Depth of Flow-
  • Depth of Flow=(Environmental Discharge/Integration Constant)^(1/Constant for a 6-inch Parshall flume)OpenImg
Can the Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge be negative?
Yes, the Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge, measured in Length can be negative.
Which unit is used to measure Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge?
Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Depth of Flow in Upstream Leg of Flume at One Third Point given Discharge can be measured.
Copied!