Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in Formula

Fx Copy
LaTeX Copy
The Depth refers to the vertical distance from a reference point to the bottom of a body of water or to a specific depth below the water surface. Check FAQs
D=((Qi0.6Ao)2)(12g)
D - Depth?Qi - Inlet Capacity?Ao - Area of Opening?g - Acceleration due to Gravity?

Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in Example

With values
With units
Only example

Here is how the Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in equation looks like with Values.

Here is how the Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in equation looks like with Units.

Here is how the Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in equation looks like.

3.0005Edit=((42Edit0.69.128Edit)2)(129.8Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in

Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in Solution

Follow our step by step solution on how to calculate Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in?

FIRST Step Consider the formula
D=((Qi0.6Ao)2)(12g)
Next Step Substitute values of Variables
D=((42m³/s0.69.128)2)(129.8m/s²)
Next Step Prepare to Evaluate
D=((420.69.128)2)(129.8)
Next Step Evaluate
D=3.00046624845128m
LAST Step Rounding Answer
D=3.0005m

Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in Formula Elements

Variables
Depth
The Depth refers to the vertical distance from a reference point to the bottom of a body of water or to a specific depth below the water surface.
Symbol: D
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Inlet Capacity
The Inlet Capacity refers to the maximum rate at which a storm water inlet or drainage structure can accept and convey water without causing flooding or other adverse impacts.
Symbol: Qi
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Area of Opening
The Area of Opening refers to the physical space in a structure or barrier through which air, water, or other substances can pass.
Symbol: Ao
Measurement: AreaUnit:
Note: Value should be greater than 0.
Acceleration due to Gravity
Acceleration due to Gravity is acceleration gained by an object because of gravitational force.
Symbol: g
Measurement: AccelerationUnit: m/s²
Note: Value should be greater than 0.

Other formulas in Disposing of Storm Water category

​Go Runoff Quantity with Full Gutter Flow
Qro=0.7Lo(a+y)32
​Go Length of Opening given Runoff Quantity with Full Gutter Flow
Lo=Qro0.7(a+y)32
​Go Depression in Curb Inlet given Runoff Quantity with Full Gutter flow
a=((Qro0.7Lo)23)-y
​Go Depth of Flow at Inlet given Runoff Quantity with Full Gutter Flow
y=((Qro0.7Lo)23)-a

How to Evaluate Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in?

Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in evaluator uses Depth = ((Inlet Capacity/(0.6*Area of Opening))^2)*(1/(2*Acceleration due to Gravity)) to evaluate the Depth, The Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in is defined as the depth of flow in channel or culvert when slope of water surface and channel bottom is same and water depth remains constant. Depth is denoted by D symbol.

How to evaluate Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in using this online evaluator? To use this online evaluator for Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in, enter Inlet Capacity (Qi), Area of Opening (Ao) & Acceleration due to Gravity (g) and hit the calculate button.

FAQs on Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in

What is the formula to find Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in?
The formula of Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in is expressed as Depth = ((Inlet Capacity/(0.6*Area of Opening))^2)*(1/(2*Acceleration due to Gravity)). Here is an example- 3.000466 = ((42/(0.6*9.128))^2)*(1/(2*9.8)).
How to calculate Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in?
With Inlet Capacity (Qi), Area of Opening (Ao) & Acceleration due to Gravity (g) we can find Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in using the formula - Depth = ((Inlet Capacity/(0.6*Area of Opening))^2)*(1/(2*Acceleration due to Gravity)).
Can the Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in be negative?
Yes, the Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in, measured in Length can be negative.
Which unit is used to measure Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in?
Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in can be measured.
Copied!