Density of Manometric Liquid given Venturi Head Formula

Fx Copy
LaTeX Copy
The Weight per unit Volume of Manometer Fluid is obtained as the product of the density of manometric fluid and acceleration of gravity g. Check FAQs
𝑤=γf(hventuriL+1)
𝑤 - Weight per unit Volume of Manometer Fluid?γf - Specific Weight of Liquid?hventuri - Venturi Head?L - Length of Venturi meter?

Density of Manometric Liquid given Venturi Head Example

With values
With units
Only example

Here is how the Density of Manometric Liquid given Venturi Head equation looks like with Values.

Here is how the Density of Manometric Liquid given Venturi Head equation looks like with Units.

Here is how the Density of Manometric Liquid given Venturi Head equation looks like.

9888.48Edit=9.81Edit(24Edit3Edit+1)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Hydraulics and Waterworks » fx Density of Manometric Liquid given Venturi Head

Density of Manometric Liquid given Venturi Head Solution

Follow our step by step solution on how to calculate Density of Manometric Liquid given Venturi Head?

FIRST Step Consider the formula
𝑤=γf(hventuriL+1)
Next Step Substitute values of Variables
𝑤=9.81kN/m³(24mm3m+1)
Next Step Convert Units
𝑤=9810N/m³(0.024m3m+1)
Next Step Prepare to Evaluate
𝑤=9810(0.0243+1)
LAST Step Evaluate
𝑤=9888.48N/m³

Density of Manometric Liquid given Venturi Head Formula Elements

Variables
Weight per unit Volume of Manometer Fluid
The Weight per unit Volume of Manometer Fluid is obtained as the product of the density of manometric fluid and acceleration of gravity g.
Symbol: 𝑤
Measurement: Specific WeightUnit: N/m³
Note: Value should be greater than 0.
Specific Weight of Liquid
The Specific Weight of Liquid refers to the weight per unit volume of that substance.
Symbol: γf
Measurement: Specific WeightUnit: kN/m³
Note: Value should be greater than 0.
Venturi Head
The Venturi head refers to the difference between pressure head at inlet and pressure head at the throat.
Symbol: hventuri
Measurement: LengthUnit: mm
Note: Value can be positive or negative.
Length of Venturi meter
The Length of Venturi meter refers to the measurement or extent of something from end to end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other formulas in Venturi Meter category

​Go Theoretical Discharge through Pipe
Qth=AiAf(2[g]hventuri)(Ai)2-(Af)2
​Go Throat Area given Theoretical Discharge
Af=(AiQth)2(Ai22[g]hventuri)+Qth2
​Go Inlet Area given Theoretical Discharge
Ai=(QthAf)2(Qth)2-(Af22[g]hventuri)
​Go Venturi Head given Theoretical Discharge through Pipe
hventuri=((QthAiAf)((Ai)2-(Af)22[g]))2

How to Evaluate Density of Manometric Liquid given Venturi Head?

Density of Manometric Liquid given Venturi Head evaluator uses Weight per unit Volume of Manometer Fluid = Specific Weight of Liquid*(Venturi Head/Length of Venturi meter+1) to evaluate the Weight per unit Volume of Manometer Fluid, The Density of Manometric Liquid given Venturi Head formula is defined as density of measuring fluid used in manometer. Weight per unit Volume of Manometer Fluid is denoted by 𝑤 symbol.

How to evaluate Density of Manometric Liquid given Venturi Head using this online evaluator? To use this online evaluator for Density of Manometric Liquid given Venturi Head, enter Specific Weight of Liquid f), Venturi Head (hventuri) & Length of Venturi meter (L) and hit the calculate button.

FAQs on Density of Manometric Liquid given Venturi Head

What is the formula to find Density of Manometric Liquid given Venturi Head?
The formula of Density of Manometric Liquid given Venturi Head is expressed as Weight per unit Volume of Manometer Fluid = Specific Weight of Liquid*(Venturi Head/Length of Venturi meter+1). Here is an example- 9888.48 = 9810*(0.024/3+1).
How to calculate Density of Manometric Liquid given Venturi Head?
With Specific Weight of Liquid f), Venturi Head (hventuri) & Length of Venturi meter (L) we can find Density of Manometric Liquid given Venturi Head using the formula - Weight per unit Volume of Manometer Fluid = Specific Weight of Liquid*(Venturi Head/Length of Venturi meter+1).
Can the Density of Manometric Liquid given Venturi Head be negative?
No, the Density of Manometric Liquid given Venturi Head, measured in Specific Weight cannot be negative.
Which unit is used to measure Density of Manometric Liquid given Venturi Head?
Density of Manometric Liquid given Venturi Head is usually measured using the Newton per Cubic Meter[N/m³] for Specific Weight. Newton per Cubic Centimeter[N/m³], Newton per Cubic Millimeter[N/m³], Kilonewton per Cubic Meter[N/m³] are the few other units in which Density of Manometric Liquid given Venturi Head can be measured.
Copied!