D.O Saturation for Sewage when Correction Factor is 0.85 Formula

Fx Copy
LaTeX Copy
D.O Saturation when Correction Factor is 0.85 is the maximum concentration of dissolved oxygen, when the actual D.O. saturation level in sewage is 85% of the theoretical D.O. saturation level. Check FAQs
DO0.85=(N9.17Ns0.85(1.024)T-20)+DL
DO0.85 - D.O Saturation when Correction Factor is 0.85?N - Oxygen Transferred?Ns - Oxygen Transfer Capacity?T - Temperature?DL - Operation Dissolved Oxygen?

D.O Saturation for Sewage when Correction Factor is 0.85 Example

With values
With units
Only example

Here is how the D.O Saturation for Sewage when Correction Factor is 0.85 equation looks like with Values.

Here is how the D.O Saturation for Sewage when Correction Factor is 0.85 equation looks like with Units.

Here is how the D.O Saturation for Sewage when Correction Factor is 0.85 equation looks like.

3414.5555Edit=(3Edit9.172.03Edit0.85(1.024)85Edit-20)+2.01Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx D.O Saturation for Sewage when Correction Factor is 0.85

D.O Saturation for Sewage when Correction Factor is 0.85 Solution

Follow our step by step solution on how to calculate D.O Saturation for Sewage when Correction Factor is 0.85?

FIRST Step Consider the formula
DO0.85=(N9.17Ns0.85(1.024)T-20)+DL
Next Step Substitute values of Variables
DO0.85=(3kg/h/kW9.172.03kg/h/kW0.85(1.024)85K-20)+2.01mg/L
Next Step Convert Units
DO0.85=(8.3E-7kg/s/W9.175.6E-7kg/s/W0.85(1.024)85K-20)+0.002kg/m³
Next Step Prepare to Evaluate
DO0.85=(8.3E-79.175.6E-70.85(1.024)85-20)+0.002
Next Step Evaluate
DO0.85=3.41455545734145kg/m³
Next Step Convert to Output's Unit
DO0.85=3414.55545734145mg/L
LAST Step Rounding Answer
DO0.85=3414.5555mg/L

D.O Saturation for Sewage when Correction Factor is 0.85 Formula Elements

Variables
D.O Saturation when Correction Factor is 0.85
D.O Saturation when Correction Factor is 0.85 is the maximum concentration of dissolved oxygen, when the actual D.O. saturation level in sewage is 85% of the theoretical D.O. saturation level.
Symbol: DO0.85
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Oxygen Transferred
Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
Symbol: N
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Oxygen Transfer Capacity
Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Symbol: Ns
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Temperature
Temperature is the degree or intensity of heat present in a substance or object.
Symbol: T
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Operation Dissolved Oxygen
Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms.
Symbol: DL
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.

Other formulas in D.O Saturation category

​Go Dissolved Oxygen Saturation for Sewage
DS=(N9.17NsCf(1.024)T-20)+DL
​Go D.O Saturation for Sewage when Correction Factor is 0.8
DO0.8=(N9.17Ns0.8(1.024)T-20)+DL

How to Evaluate D.O Saturation for Sewage when Correction Factor is 0.85?

D.O Saturation for Sewage when Correction Factor is 0.85 evaluator uses D.O Saturation when Correction Factor is 0.85 = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*0.85*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen to evaluate the D.O Saturation when Correction Factor is 0.85, The D.O Saturation for Sewage when Correction Factor is 0.85 formula is defined as the maximum concentration of dissolved oxygen, when the actual D.O. saturation level in sewage is 85% of the theoretical D.O. saturation level. D.O Saturation when Correction Factor is 0.85 is denoted by DO0.85 symbol.

How to evaluate D.O Saturation for Sewage when Correction Factor is 0.85 using this online evaluator? To use this online evaluator for D.O Saturation for Sewage when Correction Factor is 0.85, enter Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Temperature (T) & Operation Dissolved Oxygen (DL) and hit the calculate button.

FAQs on D.O Saturation for Sewage when Correction Factor is 0.85

What is the formula to find D.O Saturation for Sewage when Correction Factor is 0.85?
The formula of D.O Saturation for Sewage when Correction Factor is 0.85 is expressed as D.O Saturation when Correction Factor is 0.85 = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*0.85*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen. Here is an example- 3.4E+6 = ((8.33333333333333E-07*9.17)/(5.63888888888889E-07*0.85*(1.024)^(85-20)))+0.00201.
How to calculate D.O Saturation for Sewage when Correction Factor is 0.85?
With Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Temperature (T) & Operation Dissolved Oxygen (DL) we can find D.O Saturation for Sewage when Correction Factor is 0.85 using the formula - D.O Saturation when Correction Factor is 0.85 = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*0.85*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen.
Can the D.O Saturation for Sewage when Correction Factor is 0.85 be negative?
No, the D.O Saturation for Sewage when Correction Factor is 0.85, measured in Density cannot be negative.
Which unit is used to measure D.O Saturation for Sewage when Correction Factor is 0.85?
D.O Saturation for Sewage when Correction Factor is 0.85 is usually measured using the Milligram per Liter[mg/L] for Density. Kilogram per Cubic Meter[mg/L], Kilogram per Cubic Centimeter[mg/L], Gram per Cubic Meter[mg/L] are the few other units in which D.O Saturation for Sewage when Correction Factor is 0.85 can be measured.
Copied!