DC Meter Sensitivity Formula

Fx Copy
LaTeX Copy
DC Meter Sensitivity is the ability of meter to detect small changes in current or voltage. Check FAQs
Sdc=1Ifs
Sdc - DC Meter Sensitivity?Ifs - Full Scale Current?

DC Meter Sensitivity Example

With values
With units
Only example

Here is how the DC Meter Sensitivity equation looks like with Values.

Here is how the DC Meter Sensitivity equation looks like with Units.

Here is how the DC Meter Sensitivity equation looks like.

0.8Edit=11.25Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Instrument Analysis » fx DC Meter Sensitivity

DC Meter Sensitivity Solution

Follow our step by step solution on how to calculate DC Meter Sensitivity?

FIRST Step Consider the formula
Sdc=1Ifs
Next Step Substitute values of Variables
Sdc=11.25A
Next Step Prepare to Evaluate
Sdc=11.25
LAST Step Evaluate
Sdc=0.8Ω/V

DC Meter Sensitivity Formula Elements

Variables
DC Meter Sensitivity
DC Meter Sensitivity is the ability of meter to detect small changes in current or voltage.
Symbol: Sdc
Measurement: Meter SensitivityUnit: Ω/V
Note: Value should be greater than 0.
Full Scale Current
Full Scale Current refers to the maximum current level that a measuring instrument or device is capable of accurately measuring or indicating across its entire range.
Symbol: Ifs
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.

Other formulas in Instrument Characteristics category

​Go Sensitivity
S=QoutQin
​Go Magnitude of Output Response
Qout=SQin
​Go Magnitude of Input
Qin=QoutS
​Go Inverse Sensitivity or Scale Factor
SF=1S

How to Evaluate DC Meter Sensitivity?

DC Meter Sensitivity evaluator uses DC Meter Sensitivity = 1/Full Scale Current to evaluate the DC Meter Sensitivity, The DC Meter Sensitivity describes the smallest absolute amount of change that can be detected by a measurement. DC Meter Sensitivity is denoted by Sdc symbol.

How to evaluate DC Meter Sensitivity using this online evaluator? To use this online evaluator for DC Meter Sensitivity, enter Full Scale Current (Ifs) and hit the calculate button.

FAQs on DC Meter Sensitivity

What is the formula to find DC Meter Sensitivity?
The formula of DC Meter Sensitivity is expressed as DC Meter Sensitivity = 1/Full Scale Current. Here is an example- 0.666667 = 1/1.25.
How to calculate DC Meter Sensitivity?
With Full Scale Current (Ifs) we can find DC Meter Sensitivity using the formula - DC Meter Sensitivity = 1/Full Scale Current.
Can the DC Meter Sensitivity be negative?
No, the DC Meter Sensitivity, measured in Meter Sensitivity cannot be negative.
Which unit is used to measure DC Meter Sensitivity?
DC Meter Sensitivity is usually measured using the Ohm Per Volt[Ω/V] for Meter Sensitivity. are the few other units in which DC Meter Sensitivity can be measured.