Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode Formula

Fx Copy
LaTeX Copy
The Cut-off Frequency Circular Waveguide TE11 mode refers to the lowest frequency at which this particular mode can propagate through the waveguide. Check FAQs
fc,TE11=[c]1.8412πRcircular
fc,TE11 - Cut-off Frequency Circular Waveguide TE11?Rcircular - Radius of Circular Waveguide?[c] - Light speed in vacuum?π - Archimedes' constant?

Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode Example

With values
With units
Only example

Here is how the Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode equation looks like with Values.

Here is how the Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode equation looks like with Units.

Here is how the Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode equation looks like.

878.4046Edit=3E+81.84123.141610Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Microwave Theory » fx Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode

Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode Solution

Follow our step by step solution on how to calculate Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode?

FIRST Step Consider the formula
fc,TE11=[c]1.8412πRcircular
Next Step Substitute values of Variables
fc,TE11=[c]1.8412π10cm
Next Step Substitute values of Constants
fc,TE11=3E+8m/s1.84123.141610cm
Next Step Convert Units
fc,TE11=3E+8m/s1.84123.14160.1m
Next Step Prepare to Evaluate
fc,TE11=3E+81.84123.14160.1
Next Step Evaluate
fc,TE11=878404643.815521Hz
Next Step Convert to Output's Unit
fc,TE11=878.404643815521MHz
LAST Step Rounding Answer
fc,TE11=878.4046MHz

Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode Formula Elements

Variables
Constants
Cut-off Frequency Circular Waveguide TE11
The Cut-off Frequency Circular Waveguide TE11 mode refers to the lowest frequency at which this particular mode can propagate through the waveguide.
Symbol: fc,TE11
Measurement: FrequencyUnit: MHz
Note: Value should be greater than 0.
Radius of Circular Waveguide
The Radius of Circular Waveguide typically refers to the physical radius of a circular waveguide, which is a type of transmission line used for guiding electromagnetic waves.
Symbol: Rcircular
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Light speed in vacuum
Light speed in vacuum is a fundamental physical constant representing the speed at which light propagates through a vacuum.
Symbol: [c]
Value: 299792458.0 m/s
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Microwave Devices category

​Go Force Exerted on Particle
Fe=(qvcp)B
​Go Power Losses for TEM Mode
Ploss=2αPt
​Go Quality Factor
Q=ω0EmaxPavg
​Go Characteristic Wave Impedance
Z=ω0μβ

How to Evaluate Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode?

Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode evaluator uses Cut-off Frequency Circular Waveguide TE11 = ([c]*1.841)/(2*pi*Radius of Circular Waveguide) to evaluate the Cut-off Frequency Circular Waveguide TE11, The Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode is the lowest frequency supporting this fundamental mode, vital for designing effective communication systems. Cut-off Frequency Circular Waveguide TE11 is denoted by fc,TE11 symbol.

How to evaluate Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode using this online evaluator? To use this online evaluator for Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode, enter Radius of Circular Waveguide (Rcircular) and hit the calculate button.

FAQs on Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode

What is the formula to find Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode?
The formula of Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode is expressed as Cut-off Frequency Circular Waveguide TE11 = ([c]*1.841)/(2*pi*Radius of Circular Waveguide). Here is an example- 0.000878 = ([c]*1.841)/(2*pi*0.1).
How to calculate Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode?
With Radius of Circular Waveguide (Rcircular) we can find Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode using the formula - Cut-off Frequency Circular Waveguide TE11 = ([c]*1.841)/(2*pi*Radius of Circular Waveguide). This formula also uses Light speed in vacuum, Archimedes' constant .
Can the Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode be negative?
No, the Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode, measured in Frequency cannot be negative.
Which unit is used to measure Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode?
Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode is usually measured using the Megahertz[MHz] for Frequency. Hertz[MHz], Petahertz[MHz], Terahertz[MHz] are the few other units in which Cut-off Frequency of Circular Waveguide in Transverse Electric 11 Mode can be measured.
Copied!