Critical Temperature is the highest temperature at which the substance can exist as a liquid. At this phase boundaries vanish, and the substance can exist both as a liquid and vapor. Check FAQs
Tc=(83)(PcVcr[R])
Tc - Critical Temperature?Pc - Critical Pressure?Vcr - Critical Volume?[R] - Universal gas constant?

Critical Temperature without use of Van der Waals Constant Example

With values
With units
Only example

Here is how the Critical Temperature without use of Van der Waals Constant equation looks like with Values.

Here is how the Critical Temperature without use of Van der Waals Constant equation looks like with Units.

Here is how the Critical Temperature without use of Van der Waals Constant equation looks like.

0.3496Edit=(83)(218Edit5Edit8.3145)
You are here -
HomeIcon Home » Category Chemistry » Category Kinetic Theory of Gases » Category Van der Waals Constant » fx Critical Temperature without use of Van der Waals Constant

Critical Temperature without use of Van der Waals Constant Solution

Follow our step by step solution on how to calculate Critical Temperature without use of Van der Waals Constant?

FIRST Step Consider the formula
Tc=(83)(PcVcr[R])
Next Step Substitute values of Variables
Tc=(83)(218Pa5L[R])
Next Step Substitute values of Constants
Tc=(83)(218Pa5L8.3145)
Next Step Convert Units
Tc=(83)(218Pa0.0058.3145)
Next Step Prepare to Evaluate
Tc=(83)(2180.0058.3145)
Next Step Evaluate
Tc=0.34959164532419K
LAST Step Rounding Answer
Tc=0.3496K

Critical Temperature without use of Van der Waals Constant Formula Elements

Variables
Constants
Critical Temperature
Critical Temperature is the highest temperature at which the substance can exist as a liquid. At this phase boundaries vanish, and the substance can exist both as a liquid and vapor.
Symbol: Tc
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Critical Pressure
Critical Pressure is the minimum pressure required to liquify a substance at the critical temperature.
Symbol: Pc
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Critical Volume
The Critical Volume is the volume occupied by the unit mass of gas at critical temperature and pressure.
Symbol: Vcr
Measurement: VolumeUnit: L
Note: Value should be greater than 0.
Universal gas constant
Universal gas constant is a fundamental physical constant that appears in the ideal gas law, relating the pressure, volume, and temperature of an ideal gas.
Symbol: [R]
Value: 8.31446261815324

Other Formulas to find Critical Temperature

​Go Critical Temperature given Van der Waals Constants
Tc=8a27b[R]

Other formulas in Van der Waals Constant category

​Go Van der Waals Constant b given Boyle Temperature
b=(a[R]Tb)
​Go Van der Waals Constant b given Critical Pressure
b=a27Pc
​Go Van der Waals Constant b given Critical Temperature
b=8a27Tc[R]
​Go Van der Waals Constant b given Critical Volume
b=(Vcr3)

How to Evaluate Critical Temperature without use of Van der Waals Constant?

Critical Temperature without use of Van der Waals Constant evaluator uses Critical Temperature = (8/3)*((Critical Pressure*Critical Volume)/[R]) to evaluate the Critical Temperature, The Critical temperature without use of Van der Waals constant formula is defined as the product of critical pressure and volume of the gas. Critical Temperature is denoted by Tc symbol.

How to evaluate Critical Temperature without use of Van der Waals Constant using this online evaluator? To use this online evaluator for Critical Temperature without use of Van der Waals Constant, enter Critical Pressure (Pc) & Critical Volume (Vcr) and hit the calculate button.

FAQs on Critical Temperature without use of Van der Waals Constant

What is the formula to find Critical Temperature without use of Van der Waals Constant?
The formula of Critical Temperature without use of Van der Waals Constant is expressed as Critical Temperature = (8/3)*((Critical Pressure*Critical Volume)/[R]). Here is an example- 0.349592 = (8/3)*((218*0.005)/[R]).
How to calculate Critical Temperature without use of Van der Waals Constant?
With Critical Pressure (Pc) & Critical Volume (Vcr) we can find Critical Temperature without use of Van der Waals Constant using the formula - Critical Temperature = (8/3)*((Critical Pressure*Critical Volume)/[R]). This formula also uses Universal gas constant .
What are the other ways to Calculate Critical Temperature?
Here are the different ways to Calculate Critical Temperature-
  • Critical Temperature=(8*Van der Waals Constant a)/(27*Van der Waals Constant b*[R])OpenImg
Can the Critical Temperature without use of Van der Waals Constant be negative?
No, the Critical Temperature without use of Van der Waals Constant, measured in Temperature cannot be negative.
Which unit is used to measure Critical Temperature without use of Van der Waals Constant?
Critical Temperature without use of Van der Waals Constant is usually measured using the Kelvin[K] for Temperature. Celsius[K], Fahrenheit[K], Rankine[K] are the few other units in which Critical Temperature without use of Van der Waals Constant can be measured.
Copied!