Fx Copy
LaTeX Copy
Critical Temperature of Real Gas is the highest temperature at which the substance can exist as a liquid. At this phase boundaries vanish, and the substance can exist both as a liquid and vapor. Check FAQs
T'c=15P,cV'c4[R]
T'c - Critical Temperature of Real Gas?P,c - Critical Pressure for Peng Robinson Model?V'c - Critical Molar Volume for Peng Robinson Model?[R] - Universal gas constant?

Critical Temperature of Wohl's Real Gas given other Critical Parameters Example

With values
With units
Only example

Here is how the Critical Temperature of Wohl's Real Gas given other Critical Parameters equation looks like with Values.

Here is how the Critical Temperature of Wohl's Real Gas given other Critical Parameters equation looks like with Units.

Here is how the Critical Temperature of Wohl's Real Gas given other Critical Parameters equation looks like.

5186.7453Edit=154.6E+6Edit0.0025Edit48.3145
You are here -
HomeIcon Home » Category Chemistry » Category Kinetic Theory of Gases » Category Real Gas » fx Critical Temperature of Wohl's Real Gas given other Critical Parameters

Critical Temperature of Wohl's Real Gas given other Critical Parameters Solution

Follow our step by step solution on how to calculate Critical Temperature of Wohl's Real Gas given other Critical Parameters?

FIRST Step Consider the formula
T'c=15P,cV'c4[R]
Next Step Substitute values of Variables
T'c=154.6E+6Pa0.0025m³/mol4[R]
Next Step Substitute values of Constants
T'c=154.6E+6Pa0.0025m³/mol48.3145
Next Step Prepare to Evaluate
T'c=154.6E+60.002548.3145
Next Step Evaluate
T'c=5186.74531121756K
LAST Step Rounding Answer
T'c=5186.7453K

Critical Temperature of Wohl's Real Gas given other Critical Parameters Formula Elements

Variables
Constants
Critical Temperature of Real Gas
Critical Temperature of Real Gas is the highest temperature at which the substance can exist as a liquid. At this phase boundaries vanish, and the substance can exist both as a liquid and vapor.
Symbol: T'c
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Critical Pressure for Peng Robinson Model
Critical Pressure for Peng Robinson Model is the minimum pressure required to liquify a substance at the critical temperature.
Symbol: P,c
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Critical Molar Volume for Peng Robinson Model
Critical Molar Volume for Peng Robinson Model is the volume occupied by gas at critical temperature and pressure per mole.
Symbol: V'c
Measurement: Molar Magnetic SusceptibilityUnit: m³/mol
Note: Value can be positive or negative.
Universal gas constant
Universal gas constant is a fundamental physical constant that appears in the ideal gas law, relating the pressure, volume, and temperature of an ideal gas.
Symbol: [R]
Value: 8.31446261815324

Other Formulas to find Critical Temperature of Real Gas

​Go Critical Temperature of Real Gas given Wohl Parameter a. and Other Actual and Reduced Parameters
T'c=a6(PrgPr)((V'mV'r)2)
​Go Critical Temperature of Real Gas using Wohl Equation given Reduced and Actual Parameters
T'c=[R](Prg+(aVm(Vm-b))-(c(Vm3)))(Vm-b)Tr
​Go Critical Temperature of Real Gas using Wohl Equation given Reduced and Critical Parameters
T'c=[R]((PrP,c)+(a(V'rV'c)((V'rV'c)-b))-(c((V'rV'c)3)))((V'rV'c)-b)Tr
​Go Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a
T'c=a6P,c(V'c2)

How to Evaluate Critical Temperature of Wohl's Real Gas given other Critical Parameters?

Critical Temperature of Wohl's Real Gas given other Critical Parameters evaluator uses Critical Temperature of Real Gas = (15*Critical Pressure for Peng Robinson Model*Critical Molar Volume for Peng Robinson Model)/(4*[R]) to evaluate the Critical Temperature of Real Gas, The Critical Temperature of Wohl's Real Gas given other Critical Parameters formula is defined as the highest temperature at which the substance can exist as a liquid. Critical Temperature of Real Gas is denoted by T'c symbol.

How to evaluate Critical Temperature of Wohl's Real Gas given other Critical Parameters using this online evaluator? To use this online evaluator for Critical Temperature of Wohl's Real Gas given other Critical Parameters, enter Critical Pressure for Peng Robinson Model (P,c) & Critical Molar Volume for Peng Robinson Model (V'c) and hit the calculate button.

FAQs on Critical Temperature of Wohl's Real Gas given other Critical Parameters

What is the formula to find Critical Temperature of Wohl's Real Gas given other Critical Parameters?
The formula of Critical Temperature of Wohl's Real Gas given other Critical Parameters is expressed as Critical Temperature of Real Gas = (15*Critical Pressure for Peng Robinson Model*Critical Molar Volume for Peng Robinson Model)/(4*[R]). Here is an example- 0.245807 = (15*4600000*0.0025)/(4*[R]).
How to calculate Critical Temperature of Wohl's Real Gas given other Critical Parameters?
With Critical Pressure for Peng Robinson Model (P,c) & Critical Molar Volume for Peng Robinson Model (V'c) we can find Critical Temperature of Wohl's Real Gas given other Critical Parameters using the formula - Critical Temperature of Real Gas = (15*Critical Pressure for Peng Robinson Model*Critical Molar Volume for Peng Robinson Model)/(4*[R]). This formula also uses Universal gas constant .
What are the other ways to Calculate Critical Temperature of Real Gas?
Here are the different ways to Calculate Critical Temperature of Real Gas-
  • Critical Temperature of Real Gas=Wohl Parameter a/(6*(Pressure of Gas/Reduced Pressure)*((Molar Volume of Real Gas/Reduced Molar Volume for P-R Method)^2))OpenImg
  • Critical Temperature of Real Gas=([R]/((Pressure of Gas+(Wohl Parameter a/(Molar Volume*(Molar Volume-Wohl Parameter b)))-(Wohl Parameter c/((Molar Volume^3))))*(Molar Volume-Wohl Parameter b)))/Reduced TemperatureOpenImg
  • Critical Temperature of Real Gas=([R]/(((Reduced Pressure*Critical Pressure for Peng Robinson Model)+(Wohl Parameter a/((Reduced Molar Volume for P-R Method*Critical Molar Volume for Peng Robinson Model)*((Reduced Molar Volume for P-R Method*Critical Molar Volume for Peng Robinson Model)-Wohl Parameter b)))-(Wohl Parameter c/(((Reduced Molar Volume for P-R Method*Critical Molar Volume for Peng Robinson Model)^3))))*((Reduced Molar Volume for P-R Method*Critical Molar Volume for Peng Robinson Model)-Wohl Parameter b)))/Reduced TemperatureOpenImg
Can the Critical Temperature of Wohl's Real Gas given other Critical Parameters be negative?
No, the Critical Temperature of Wohl's Real Gas given other Critical Parameters, measured in Temperature cannot be negative.
Which unit is used to measure Critical Temperature of Wohl's Real Gas given other Critical Parameters?
Critical Temperature of Wohl's Real Gas given other Critical Parameters is usually measured using the Kelvin[K] for Temperature. Celsius[K], Fahrenheit[K], Rankine[K] are the few other units in which Critical Temperature of Wohl's Real Gas given other Critical Parameters can be measured.
Copied!