Fx Copy
LaTeX Copy
Critical Temperature of Real Gas is the highest temperature at which the substance can exist as a liquid. At this phase boundaries vanish, and the substance can exist both as a liquid and vapor. Check FAQs
T'c=a6P,c(V'c2)
T'c - Critical Temperature of Real Gas?a - Wohl Parameter a?P,c - Critical Pressure for Peng Robinson Model?V'c - Critical Molar Volume for Peng Robinson Model?

Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a Example

With values
With units
Only example

Here is how the Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a equation looks like with Values.

Here is how the Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a equation looks like with Units.

Here is how the Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a equation looks like.

1.542Edit=266Edit64.6E+6Edit(0.0025Edit2)
You are here -
HomeIcon Home » Category Chemistry » Category Kinetic Theory of Gases » Category Real Gas » fx Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a

Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a Solution

Follow our step by step solution on how to calculate Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a?

FIRST Step Consider the formula
T'c=a6P,c(V'c2)
Next Step Substitute values of Variables
T'c=26664.6E+6Pa(0.0025m³/mol2)
Next Step Prepare to Evaluate
T'c=26664.6E+6(0.00252)
Next Step Evaluate
T'c=1.54202898550725K
LAST Step Rounding Answer
T'c=1.542K

Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a Formula Elements

Variables
Critical Temperature of Real Gas
Critical Temperature of Real Gas is the highest temperature at which the substance can exist as a liquid. At this phase boundaries vanish, and the substance can exist both as a liquid and vapor.
Symbol: T'c
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Wohl Parameter a
Wohl parameter a is an empirical parameter characteristic to equation obtained from Wohl model of real gas.
Symbol: a
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Critical Pressure for Peng Robinson Model
Critical Pressure for Peng Robinson Model is the minimum pressure required to liquify a substance at the critical temperature.
Symbol: P,c
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Critical Molar Volume for Peng Robinson Model
Critical Molar Volume for Peng Robinson Model is the volume occupied by gas at critical temperature and pressure per mole.
Symbol: V'c
Measurement: Molar Magnetic SusceptibilityUnit: m³/mol
Note: Value can be positive or negative.

Other Formulas to find Critical Temperature of Real Gas

​Go Critical Temperature of Real Gas given Wohl Parameter a. and Other Actual and Reduced Parameters
T'c=a6(PrgPr)((V'mV'r)2)
​Go Critical Temperature of Real Gas using Wohl Equation given Reduced and Actual Parameters
T'c=[R](Prg+(aVm(Vm-b))-(c(Vm3)))(Vm-b)Tr
​Go Critical Temperature of Real Gas using Wohl Equation given Reduced and Critical Parameters
T'c=[R]((PrP,c)+(a(V'rV'c)((V'rV'c)-b))-(c((V'rV'c)3)))((V'rV'c)-b)Tr
​Go Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter b
T'c=b15P,c[R]

How to Evaluate Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a?

Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a evaluator uses Critical Temperature of Real Gas = Wohl Parameter a/(6*Critical Pressure for Peng Robinson Model*(Critical Molar Volume for Peng Robinson Model^2)) to evaluate the Critical Temperature of Real Gas, The Critical Temperature of real gas using Wohl equation given Wohl parameter a formula is defined as the highest temperature at which the substance can exist as a liquid. Critical Temperature of Real Gas is denoted by T'c symbol.

How to evaluate Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a using this online evaluator? To use this online evaluator for Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a, enter Wohl Parameter a (a), Critical Pressure for Peng Robinson Model (P,c) & Critical Molar Volume for Peng Robinson Model (V'c) and hit the calculate button.

FAQs on Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a

What is the formula to find Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a?
The formula of Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a is expressed as Critical Temperature of Real Gas = Wohl Parameter a/(6*Critical Pressure for Peng Robinson Model*(Critical Molar Volume for Peng Robinson Model^2)). Here is an example- 154.4 = 266/(6*4600000*(0.0025^2)).
How to calculate Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a?
With Wohl Parameter a (a), Critical Pressure for Peng Robinson Model (P,c) & Critical Molar Volume for Peng Robinson Model (V'c) we can find Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a using the formula - Critical Temperature of Real Gas = Wohl Parameter a/(6*Critical Pressure for Peng Robinson Model*(Critical Molar Volume for Peng Robinson Model^2)).
What are the other ways to Calculate Critical Temperature of Real Gas?
Here are the different ways to Calculate Critical Temperature of Real Gas-
  • Critical Temperature of Real Gas=Wohl Parameter a/(6*(Pressure of Gas/Reduced Pressure)*((Molar Volume of Real Gas/Reduced Molar Volume for P-R Method)^2))OpenImg
  • Critical Temperature of Real Gas=([R]/((Pressure of Gas+(Wohl Parameter a/(Molar Volume*(Molar Volume-Wohl Parameter b)))-(Wohl Parameter c/((Molar Volume^3))))*(Molar Volume-Wohl Parameter b)))/Reduced TemperatureOpenImg
  • Critical Temperature of Real Gas=([R]/(((Reduced Pressure*Critical Pressure for Peng Robinson Model)+(Wohl Parameter a/((Reduced Molar Volume for P-R Method*Critical Molar Volume for Peng Robinson Model)*((Reduced Molar Volume for P-R Method*Critical Molar Volume for Peng Robinson Model)-Wohl Parameter b)))-(Wohl Parameter c/(((Reduced Molar Volume for P-R Method*Critical Molar Volume for Peng Robinson Model)^3))))*((Reduced Molar Volume for P-R Method*Critical Molar Volume for Peng Robinson Model)-Wohl Parameter b)))/Reduced TemperatureOpenImg
Can the Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a be negative?
No, the Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a, measured in Temperature cannot be negative.
Which unit is used to measure Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a?
Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a is usually measured using the Kelvin[K] for Temperature. Celsius[K], Fahrenheit[K], Rankine[K] are the few other units in which Critical Temperature of Real Gas using Wohl Equation given Wohl Parameter a can be measured.
Copied!