Fx Copy
LaTeX Copy
The Critical Depth of Parabolic Channel is defined as the depth of flow where energy is at a minimum for a particular discharge. Check FAQs
hp=Ec43
hp - Critical Depth of Parabolic Channel?Ec - Critical energy of Parabolic Channel?

Critical Depth of Flow given Critical Energy for Parabolic Channel Example

With values
With units
Only example

Here is how the Critical Depth of Flow given Critical Energy for Parabolic Channel equation looks like with Values.

Here is how the Critical Depth of Flow given Critical Energy for Parabolic Channel equation looks like with Units.

Here is how the Critical Depth of Flow given Critical Energy for Parabolic Channel equation looks like.

142.5Edit=190Edit43
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Hydraulics and Waterworks » fx Critical Depth of Flow given Critical Energy for Parabolic Channel

Critical Depth of Flow given Critical Energy for Parabolic Channel Solution

Follow our step by step solution on how to calculate Critical Depth of Flow given Critical Energy for Parabolic Channel?

FIRST Step Consider the formula
hp=Ec43
Next Step Substitute values of Variables
hp=190m43
Next Step Prepare to Evaluate
hp=19043
LAST Step Evaluate
hp=142.5m

Critical Depth of Flow given Critical Energy for Parabolic Channel Formula Elements

Variables
Critical Depth of Parabolic Channel
The Critical Depth of Parabolic Channel is defined as the depth of flow where energy is at a minimum for a particular discharge.
Symbol: hp
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Critical energy of Parabolic Channel
Critical energy of parabolic channel is the total energy (both potential and kinetic energy) at the point of jump formation.
Symbol: Ec
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Critical Depth of Parabolic Channel

​Go Critical Depth for Parabolic Channel
hp=(3.375(QS)2[g])14

Other formulas in Critical Flow and its Computation category

​Go Critical Section Factor
Z=Q[g]
​Go Discharge given Critical Section Factor
Q=Z[g]
​Go Critical Depth for Rectangular Channel
hr=(q2[g])13
​Go Discharge per unit Width given Critical Depth for Rectangular Channel
q=((hr3)[g])12

How to Evaluate Critical Depth of Flow given Critical Energy for Parabolic Channel?

Critical Depth of Flow given Critical Energy for Parabolic Channel evaluator uses Critical Depth of Parabolic Channel = Critical energy of Parabolic Channel/(4/3) to evaluate the Critical Depth of Parabolic Channel, The Critical Depth of Flow given Critical Energy for Parabolic Channel is defined as the depth at which minimum energy is obtained in open channel flow. Critical Depth of Parabolic Channel is denoted by hp symbol.

How to evaluate Critical Depth of Flow given Critical Energy for Parabolic Channel using this online evaluator? To use this online evaluator for Critical Depth of Flow given Critical Energy for Parabolic Channel, enter Critical energy of Parabolic Channel (Ec) and hit the calculate button.

FAQs on Critical Depth of Flow given Critical Energy for Parabolic Channel

What is the formula to find Critical Depth of Flow given Critical Energy for Parabolic Channel?
The formula of Critical Depth of Flow given Critical Energy for Parabolic Channel is expressed as Critical Depth of Parabolic Channel = Critical energy of Parabolic Channel/(4/3). Here is an example- 142.5 = 190/(4/3).
How to calculate Critical Depth of Flow given Critical Energy for Parabolic Channel?
With Critical energy of Parabolic Channel (Ec) we can find Critical Depth of Flow given Critical Energy for Parabolic Channel using the formula - Critical Depth of Parabolic Channel = Critical energy of Parabolic Channel/(4/3).
What are the other ways to Calculate Critical Depth of Parabolic Channel?
Here are the different ways to Calculate Critical Depth of Parabolic Channel-
  • Critical Depth of Parabolic Channel=(3.375*((Discharge of Channel/Bed Slope)^2)/[g])^(1/4)OpenImg
Can the Critical Depth of Flow given Critical Energy for Parabolic Channel be negative?
Yes, the Critical Depth of Flow given Critical Energy for Parabolic Channel, measured in Length can be negative.
Which unit is used to measure Critical Depth of Flow given Critical Energy for Parabolic Channel?
Critical Depth of Flow given Critical Energy for Parabolic Channel is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Critical Depth of Flow given Critical Energy for Parabolic Channel can be measured.
Copied!