Correlation for Heat Flux proposed by Mostinski Formula

Fx Copy
LaTeX Copy
The Heat Transfer Coefficient For Nucleate Boiling is the heat transferred per unit area per kelvin. Check FAQs
hb=0.00341(Pc2.3)(Te2.33)(Pr0.566)
hb - Heat Transfer Coefficient For Nucleate Boiling?Pc - Critical Pressure?Te - Excess Temperature in Nucleate Boiling?Pr - Reduced Pressure?

Correlation for Heat Flux proposed by Mostinski Example

With values
With units
Only example

Here is how the Correlation for Heat Flux proposed by Mostinski equation looks like with Values.

Here is how the Correlation for Heat Flux proposed by Mostinski equation looks like with Units.

Here is how the Correlation for Heat Flux proposed by Mostinski equation looks like.

110240.4213Edit=0.00341(5.9Edit2.3)(10Edit2.33)(1.1Edit0.566)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Heat Transfer » fx Correlation for Heat Flux proposed by Mostinski

Correlation for Heat Flux proposed by Mostinski Solution

Follow our step by step solution on how to calculate Correlation for Heat Flux proposed by Mostinski?

FIRST Step Consider the formula
hb=0.00341(Pc2.3)(Te2.33)(Pr0.566)
Next Step Substitute values of Variables
hb=0.00341(5.9Pa2.3)(10°C2.33)(1.10.566)
Next Step Convert Units
hb=0.00341(5.9Pa2.3)(283.15K2.33)(1.10.566)
Next Step Prepare to Evaluate
hb=0.00341(5.92.3)(283.152.33)(1.10.566)
Next Step Evaluate
hb=110240.421293577W/m²*K
Next Step Convert to Output's Unit
hb=110240.421293577W/m²*°C
LAST Step Rounding Answer
hb=110240.4213W/m²*°C

Correlation for Heat Flux proposed by Mostinski Formula Elements

Variables
Heat Transfer Coefficient For Nucleate Boiling
The Heat Transfer Coefficient For Nucleate Boiling is the heat transferred per unit area per kelvin.
Symbol: hb
Measurement: Heat Transfer CoefficientUnit: W/m²*°C
Note: Value should be greater than 0.
Critical Pressure
Critical Pressure is the minimum pressure required to liquify a substance at the critical temperature.
Symbol: Pc
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Excess Temperature in Nucleate Boiling
Excess Temperature in Nucleate Boiling is defined as the temperature difference between heat source and saturation temperature of the fluid.
Symbol: Te
Measurement: TemperatureUnit: °C
Note: Value should be greater than 0.
Reduced Pressure
Reduced Pressure is the ratio of the actual pressure of the fluid to its critical pressure. It is dimensionless.
Symbol: Pr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Important Formulas of Condensation Number, Average Heat Transfer Coefficient and Heat Flux category

​Go Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes
h=(2.54((ΔTx)3)exp(p1.551))
​Go Excess Temperature in Boiling
Texcess=Tsurface-TSat
​Go Critical Heat Flux by Zuber
qMax=((0.149Lvρv)((σ[g])(ρL-ρv)ρv2)14)
​Go Heat Flux in Fully Developed Boiling State for Pressure upto 0.7 Megapascal
qrate=2.253A((ΔTx)3.96)

How to Evaluate Correlation for Heat Flux proposed by Mostinski?

Correlation for Heat Flux proposed by Mostinski evaluator uses Heat Transfer Coefficient For Nucleate Boiling = 0.00341*(Critical Pressure^2.3)*(Excess Temperature in Nucleate Boiling^2.33)*(Reduced Pressure^0.566) to evaluate the Heat Transfer Coefficient For Nucleate Boiling, The Correlation for Heat Flux proposed by Mostinski formula is defined as the function of Critical Pressure, Excess Temperature and Prandtl Number. It is an Empirical co-relation derived by mostinski. Heat Transfer Coefficient For Nucleate Boiling is denoted by hb symbol.

How to evaluate Correlation for Heat Flux proposed by Mostinski using this online evaluator? To use this online evaluator for Correlation for Heat Flux proposed by Mostinski, enter Critical Pressure (Pc), Excess Temperature in Nucleate Boiling (Te) & Reduced Pressure (Pr) and hit the calculate button.

FAQs on Correlation for Heat Flux proposed by Mostinski

What is the formula to find Correlation for Heat Flux proposed by Mostinski?
The formula of Correlation for Heat Flux proposed by Mostinski is expressed as Heat Transfer Coefficient For Nucleate Boiling = 0.00341*(Critical Pressure^2.3)*(Excess Temperature in Nucleate Boiling^2.33)*(Reduced Pressure^0.566). Here is an example- 110240.4 = 0.00341*(5.9^2.3)*(283.15^2.33)*(1.1^0.566).
How to calculate Correlation for Heat Flux proposed by Mostinski?
With Critical Pressure (Pc), Excess Temperature in Nucleate Boiling (Te) & Reduced Pressure (Pr) we can find Correlation for Heat Flux proposed by Mostinski using the formula - Heat Transfer Coefficient For Nucleate Boiling = 0.00341*(Critical Pressure^2.3)*(Excess Temperature in Nucleate Boiling^2.33)*(Reduced Pressure^0.566).
Can the Correlation for Heat Flux proposed by Mostinski be negative?
No, the Correlation for Heat Flux proposed by Mostinski, measured in Heat Transfer Coefficient cannot be negative.
Which unit is used to measure Correlation for Heat Flux proposed by Mostinski?
Correlation for Heat Flux proposed by Mostinski is usually measured using the Watt per Square Meter per Celcius[W/m²*°C] for Heat Transfer Coefficient. Watt per Square Meter per Kelvin[W/m²*°C], Joule per Second per Square Meter per Kelvin[W/m²*°C], Kilocalorie (IT) per Hour per Square Foot per Celcius[W/m²*°C] are the few other units in which Correlation for Heat Flux proposed by Mostinski can be measured.
Copied!