Fx Copy
LaTeX Copy
Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error. Check FAQs
Cf=NNs(DS-DL)(1.024)T-209.17
Cf - Correction Factor?N - Oxygen Transferred?Ns - Oxygen Transfer Capacity?DS - Dissolved Oxygen Saturation?DL - Operation Dissolved Oxygen?T - Temperature?

Correction Factor given Oxygen Transfer Capacity Example

With values
With units
Only example

Here is how the Correction Factor given Oxygen Transfer Capacity equation looks like with Values.

Here is how the Correction Factor given Oxygen Transfer Capacity equation looks like with Units.

Here is how the Correction Factor given Oxygen Transfer Capacity equation looks like.

0.5Edit=3Edit2.03Edit(5803Edit-2.01Edit)(1.024)85Edit-209.17
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Correction Factor given Oxygen Transfer Capacity

Correction Factor given Oxygen Transfer Capacity Solution

Follow our step by step solution on how to calculate Correction Factor given Oxygen Transfer Capacity?

FIRST Step Consider the formula
Cf=NNs(DS-DL)(1.024)T-209.17
Next Step Substitute values of Variables
Cf=3kg/h/kW2.03kg/h/kW(5803mg/L-2.01mg/L)(1.024)85K-209.17
Next Step Convert Units
Cf=8.3E-7kg/s/W5.6E-7kg/s/W(5.803kg/m³-0.002kg/m³)(1.024)85K-209.17
Next Step Prepare to Evaluate
Cf=8.3E-75.6E-7(5.803-0.002)(1.024)85-209.17
Next Step Evaluate
Cf=0.500029070682804
LAST Step Rounding Answer
Cf=0.5

Correction Factor given Oxygen Transfer Capacity Formula Elements

Variables
Correction Factor
Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
Symbol: Cf
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Oxygen Transferred
Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
Symbol: N
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Oxygen Transfer Capacity
Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Symbol: Ns
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Dissolved Oxygen Saturation
Dissolved Oxygen Saturation is the maximum amount of oxygen that can be dissolved in water at a given temperature and pressure.
Symbol: DS
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Operation Dissolved Oxygen
Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms.
Symbol: DL
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Temperature
Temperature is the degree or intensity of heat present in a substance or object.
Symbol: T
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.

Other Formulas to find Correction Factor

​Go Correction Factor
Cf=NNsD(1.024)T-209.17

Other formulas in Oxygen Transfer Capacity category

​Go Ratio of BOD to Ultimate BOD
f=BOD5BODu
​Go BOD5 given Oxygen Required in Aeration Tank
BOD5a=BODuQs(Qi-Q)O2+(1.42QwXR)
​Go BOD5 given Ratio of BOD to Ultimate BOD
BOD5r=fBODu
​Go BOD5 when Ratio of BOD to Ultimate BOD is 0.68
BOD5=BODu0.68

How to Evaluate Correction Factor given Oxygen Transfer Capacity?

Correction Factor given Oxygen Transfer Capacity evaluator uses Correction Factor = Oxygen Transferred/((Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*(1.024)^(Temperature-20))/(9.17)) to evaluate the Correction Factor, Correction Factor given Oxygen Transfer Capacity formula is defined as a dimensionless value that adjusts the oxygen transfer rate in an aeration tank, considering factors such as temperature, oxygen deficit, and saturation concentrations, to accurately determine the oxygen requirement for wastewater treatment. Correction Factor is denoted by Cf symbol.

How to evaluate Correction Factor given Oxygen Transfer Capacity using this online evaluator? To use this online evaluator for Correction Factor given Oxygen Transfer Capacity, enter Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Dissolved Oxygen Saturation (DS), Operation Dissolved Oxygen (DL) & Temperature (T) and hit the calculate button.

FAQs on Correction Factor given Oxygen Transfer Capacity

What is the formula to find Correction Factor given Oxygen Transfer Capacity?
The formula of Correction Factor given Oxygen Transfer Capacity is expressed as Correction Factor = Oxygen Transferred/((Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*(1.024)^(Temperature-20))/(9.17)). Here is an example- 0.500029 = 8.33333333333333E-07/((5.63888888888889E-07*(5.803-0.00201)*(1.024)^(85-20))/(9.17)).
How to calculate Correction Factor given Oxygen Transfer Capacity?
With Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Dissolved Oxygen Saturation (DS), Operation Dissolved Oxygen (DL) & Temperature (T) we can find Correction Factor given Oxygen Transfer Capacity using the formula - Correction Factor = Oxygen Transferred/((Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*(1.024)^(Temperature-20))/(9.17)).
What are the other ways to Calculate Correction Factor?
Here are the different ways to Calculate Correction Factor-
  • Correction Factor=Oxygen Transferred/((Oxygen Transfer Capacity*Difference between Saturation DO and Operation DO*(1.024)^(Temperature-20))/(9.17))OpenImg
Copied!