Fx Copy
LaTeX Copy
Correction Factor refers to the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness. Check FAQs
G=QvQfe
G - Correction Factor?Qv - Discharge for Partially Penetrating Well?Qfe - Discharge for Fully Penetrating Gravity Well?

Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well Example

With values
With units
Only example

Here is how the Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well equation looks like with Values.

Here is how the Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well equation looks like with Units.

Here is how the Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well equation looks like.

0.8301Edit=5.08Edit6.12Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well

Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well Solution

Follow our step by step solution on how to calculate Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well?

FIRST Step Consider the formula
G=QvQfe
Next Step Substitute values of Variables
G=5.08m³/s6.12m³/s
Next Step Prepare to Evaluate
G=5.086.12
Next Step Evaluate
G=0.830065359477124
LAST Step Rounding Answer
G=0.8301

Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well Formula Elements

Variables
Correction Factor
Correction Factor refers to the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness.
Symbol: G
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Discharge for Partially Penetrating Well
Discharge for Partially Penetrating Well refers to the volume of water extracted from an aquifer when the well does not extend through the entire thickness of the aquifer.
Symbol: Qv
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Discharge for Fully Penetrating Gravity Well
Discharge for Fully Penetrating Gravity Well refers to the volume of water extracted from an unconfined aquifer where the well reaches the entire thickness of the aquifer.
Symbol: Qfe
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other Formulas to find Correction Factor

​Go Correction Factor for Partial Penetration given Discharge for Partially Penetrating Well
G=Qv2πKb(H-hw)log((Rr),e)

Other formulas in Partially Penetrating Artesian Well category

​Go Discharge for Partially Penetrating Well
Qv=2πKb(H-hw)Glog((Rr),e)
​Go Coefficient of Permeability given Discharge for Partially Penetrating Well
K=Qv2πb(H-hw)Glog((Rr),e)
​Go Aquifer Thickness given Discharge for Partially Penetrating Well
b=Qv2πK(H-hw)Glog((Rr),e)
​Go Thickness of Aquifer given Discharge for Partially Penetrating Well
H=hw+Qv(log((Rr),e))2πKbG

How to Evaluate Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well?

Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well evaluator uses Correction Factor = Discharge for Partially Penetrating Well/Discharge for Fully Penetrating Gravity Well to evaluate the Correction Factor, Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well formula is defined as a dimensionless quantity that accounts for the reduction in well discharge due to partial penetration of the well screen into the aquifer, providing a correction to the discharge rate of a fully penetrating well. Correction Factor is denoted by G symbol.

How to evaluate Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well using this online evaluator? To use this online evaluator for Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well, enter Discharge for Partially Penetrating Well (Qv) & Discharge for Fully Penetrating Gravity Well (Qfe) and hit the calculate button.

FAQs on Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well

What is the formula to find Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well?
The formula of Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well is expressed as Correction Factor = Discharge for Partially Penetrating Well/Discharge for Fully Penetrating Gravity Well. Here is an example- 10160 = 5.08/6.12.
How to calculate Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well?
With Discharge for Partially Penetrating Well (Qv) & Discharge for Fully Penetrating Gravity Well (Qfe) we can find Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well using the formula - Correction Factor = Discharge for Partially Penetrating Well/Discharge for Fully Penetrating Gravity Well.
What are the other ways to Calculate Correction Factor?
Here are the different ways to Calculate Correction Factor-
  • Correction Factor=Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water))/(log((Radius of Influence/Radius of Well),e)))OpenImg
Copied!