Correction Factor for Industrial Service given Design Power Formula

Fx Copy
LaTeX Copy
Correction Factor for Industrial Service is the correction factor that is used for industrial purpose. Check FAQs
Far=PdPt
Far - Correction Factor for Industrial Service?Pd - Design Power of Belt Drive?Pt - Power transmitted by belt?

Correction Factor for Industrial Service given Design Power Example

With values
With units
Only example

Here is how the Correction Factor for Industrial Service given Design Power equation looks like with Values.

Here is how the Correction Factor for Industrial Service given Design Power equation looks like with Units.

Here is how the Correction Factor for Industrial Service given Design Power equation looks like.

1.1488Edit=7.41Edit6.45Edit
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Machine Design » fx Correction Factor for Industrial Service given Design Power

Correction Factor for Industrial Service given Design Power Solution

Follow our step by step solution on how to calculate Correction Factor for Industrial Service given Design Power?

FIRST Step Consider the formula
Far=PdPt
Next Step Substitute values of Variables
Far=7.41kW6.45kW
Next Step Convert Units
Far=7410W6450W
Next Step Prepare to Evaluate
Far=74106450
Next Step Evaluate
Far=1.14883720930233
LAST Step Rounding Answer
Far=1.1488

Correction Factor for Industrial Service given Design Power Formula Elements

Variables
Correction Factor for Industrial Service
Correction Factor for Industrial Service is the correction factor that is used for industrial purpose.
Symbol: Far
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Design Power of Belt Drive
Design Power of Belt Drive is defined as the power transmitted on the basis of the design.
Symbol: Pd
Measurement: PowerUnit: kW
Note: Value should be greater than 0.
Power transmitted by belt
Power transmitted by belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
Symbol: Pt
Measurement: PowerUnit: kW
Note: Value should be greater than 0.

Other formulas in Selection of V Belts category

​Go Design Power for V Belt
Pd=FarPt
​Go Transmitted Power given Design Power
Pt=PdFar
​Go Pitch diameter of big pulley of V Belt drive
D=d(n1n2)
​Go Pitch diameter of smaller pulley given pitch diameter of big pulley
d=D(n2n1)

How to Evaluate Correction Factor for Industrial Service given Design Power?

Correction Factor for Industrial Service given Design Power evaluator uses Correction Factor for Industrial Service = Design Power of Belt Drive/Power transmitted by belt to evaluate the Correction Factor for Industrial Service, The Correction Factor for Industrial Service given Design Power is given formula is defined as the factor of correction for the industrial applications or services. Correction Factor for Industrial Service is denoted by Far symbol.

How to evaluate Correction Factor for Industrial Service given Design Power using this online evaluator? To use this online evaluator for Correction Factor for Industrial Service given Design Power, enter Design Power of Belt Drive (Pd) & Power transmitted by belt (Pt) and hit the calculate button.

FAQs on Correction Factor for Industrial Service given Design Power

What is the formula to find Correction Factor for Industrial Service given Design Power?
The formula of Correction Factor for Industrial Service given Design Power is expressed as Correction Factor for Industrial Service = Design Power of Belt Drive/Power transmitted by belt. Here is an example- 1.148837 = 7410/6450.
How to calculate Correction Factor for Industrial Service given Design Power?
With Design Power of Belt Drive (Pd) & Power transmitted by belt (Pt) we can find Correction Factor for Industrial Service given Design Power using the formula - Correction Factor for Industrial Service = Design Power of Belt Drive/Power transmitted by belt.
Copied!