Correction Factor for Arc of Contact given Number of Belts Required Formula

Fx Copy
LaTeX Copy
Correction Factor for Arc of Contact is the factor of correction for the arc of contact. Check FAQs
Fdr=PtFarFcrNPr
Fdr - Correction Factor for Arc of Contact?Pt - Power transmitted by belt?Far - Correction Factor for Industrial Service?Fcr - Correction Factor for Belt Length?N - Number of Belts?Pr - Power Rating of Single V-Belt?

Correction Factor for Arc of Contact given Number of Belts Required Example

With values
With units
Only example

Here is how the Correction Factor for Arc of Contact given Number of Belts Required equation looks like with Values.

Here is how the Correction Factor for Arc of Contact given Number of Belts Required equation looks like with Units.

Here is how the Correction Factor for Arc of Contact given Number of Belts Required equation looks like.

0.9404Edit=6.45Edit1.3Edit1.08Edit2Edit4.128Edit
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Machine Design » fx Correction Factor for Arc of Contact given Number of Belts Required

Correction Factor for Arc of Contact given Number of Belts Required Solution

Follow our step by step solution on how to calculate Correction Factor for Arc of Contact given Number of Belts Required?

FIRST Step Consider the formula
Fdr=PtFarFcrNPr
Next Step Substitute values of Variables
Fdr=6.45kW1.31.0824.128kW
Next Step Convert Units
Fdr=6450W1.31.0824128W
Next Step Prepare to Evaluate
Fdr=64501.31.0824128
Next Step Evaluate
Fdr=0.940393518518518
LAST Step Rounding Answer
Fdr=0.9404

Correction Factor for Arc of Contact given Number of Belts Required Formula Elements

Variables
Correction Factor for Arc of Contact
Correction Factor for Arc of Contact is the factor of correction for the arc of contact.
Symbol: Fdr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Power transmitted by belt
Power transmitted by belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
Symbol: Pt
Measurement: PowerUnit: kW
Note: Value should be greater than 0.
Correction Factor for Industrial Service
Correction Factor for Industrial Service is the correction factor that is used for industrial purpose.
Symbol: Far
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Correction Factor for Belt Length
Correction Factor for Belt Length is the factor of correction for the belt length.
Symbol: Fcr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Number of Belts
Number of Belts is the number of belts that are required for a given application.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Power Rating of Single V-Belt
Power Rating of Single V-Belt is the power rating given to the single V-Belt.
Symbol: Pr
Measurement: PowerUnit: kW
Note: Value should be greater than 0.

Other formulas in V Belt Characteristics and Parameters category

​Go Belt Tension in Loose Side of V-Belt
P2=P1-mvvb2eμαsin(θ2)+mvvb2
​Go Belt Tension in Tight Side of V-Belt
P1=(eμαsin(θ2))(P2-mvvb2)+mvvb2
​Go Belt Velocity of V-Belt given Belt Tension in Loose Side
vb=P1-(eμαsin(θ2))P2mv(1-(eμαsin(θ2)))
​Go Angle of Wrap of V-Belt given Belt Tension in Loose Side of Belt
α=sin(θ2)ln(P1-mvvb2P2-mvvb2)μ

How to Evaluate Correction Factor for Arc of Contact given Number of Belts Required?

Correction Factor for Arc of Contact given Number of Belts Required evaluator uses Correction Factor for Arc of Contact = Power transmitted by belt*Correction Factor for Industrial Service/(Correction Factor for Belt Length*Number of Belts*Power Rating of Single V-Belt) to evaluate the Correction Factor for Arc of Contact, The Correction Factor for Arc of Contact given Number of Belts Required formula is defined as the factor of correction for the arc of contact. Correction Factor for Arc of Contact is denoted by Fdr symbol.

How to evaluate Correction Factor for Arc of Contact given Number of Belts Required using this online evaluator? To use this online evaluator for Correction Factor for Arc of Contact given Number of Belts Required, enter Power transmitted by belt (Pt), Correction Factor for Industrial Service (Far), Correction Factor for Belt Length (Fcr), Number of Belts (N) & Power Rating of Single V-Belt (Pr) and hit the calculate button.

FAQs on Correction Factor for Arc of Contact given Number of Belts Required

What is the formula to find Correction Factor for Arc of Contact given Number of Belts Required?
The formula of Correction Factor for Arc of Contact given Number of Belts Required is expressed as Correction Factor for Arc of Contact = Power transmitted by belt*Correction Factor for Industrial Service/(Correction Factor for Belt Length*Number of Belts*Power Rating of Single V-Belt). Here is an example- 0.940394 = 6450*1.3/(1.08*2*4128).
How to calculate Correction Factor for Arc of Contact given Number of Belts Required?
With Power transmitted by belt (Pt), Correction Factor for Industrial Service (Far), Correction Factor for Belt Length (Fcr), Number of Belts (N) & Power Rating of Single V-Belt (Pr) we can find Correction Factor for Arc of Contact given Number of Belts Required using the formula - Correction Factor for Arc of Contact = Power transmitted by belt*Correction Factor for Industrial Service/(Correction Factor for Belt Length*Number of Belts*Power Rating of Single V-Belt).
Copied!