Constant Rate Injection Method or Plateau Gauging Formula

Fx Copy
LaTeX Copy
Constant Discharge Rate at C1 using the dilution principle to inject the tracer of concentration C1. Check FAQs
Qf=QsC2-C0C1-C2
Qf - Constant Discharge Rate at C1?Qs - Discharge in Stream?C2 - Concentration Profile of Tracer at Section 2?C0 - Initial Concentration of Tracer?C1 - High Concentration of Tracer at Section 1?

Constant Rate Injection Method or Plateau Gauging Example

With values
With units
Only example

Here is how the Constant Rate Injection Method or Plateau Gauging equation looks like with Values.

Here is how the Constant Rate Injection Method or Plateau Gauging equation looks like with Units.

Here is how the Constant Rate Injection Method or Plateau Gauging equation looks like.

20Edit=60Edit6Edit-4Edit12Edit-6Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Constant Rate Injection Method or Plateau Gauging

Constant Rate Injection Method or Plateau Gauging Solution

Follow our step by step solution on how to calculate Constant Rate Injection Method or Plateau Gauging?

FIRST Step Consider the formula
Qf=QsC2-C0C1-C2
Next Step Substitute values of Variables
Qf=60m³/s6-412-6
Next Step Prepare to Evaluate
Qf=606-412-6
LAST Step Evaluate
Qf=20m³/s

Constant Rate Injection Method or Plateau Gauging Formula Elements

Variables
Constant Discharge Rate at C1
Constant Discharge Rate at C1 using the dilution principle to inject the tracer of concentration C1.
Symbol: Qf
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Discharge in Stream
Discharge in Stream is the volumetric flow rate of water that is transported through a given cross-sectional area.
Symbol: Qs
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Concentration Profile of Tracer at Section 2
Concentration Profile of Tracer at Section 2 is denoted by the symbol C2.
Symbol: C2
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Initial Concentration of Tracer
Initial Concentration of Tracer in the Stream Flow.
Symbol: C0
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
High Concentration of Tracer at Section 1
High Concentration of Tracer at Section 1 in the Stream Flow.
Symbol: C1
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Dilution Technique of Streamflow Measurements category

​Go Discharge in Stream by Constant Rate Injection Method
Qs=Qf(C1-C2C2-C0)
​Go Length of Reach
L=0.13B2C(0.7C+2g)gdavg
​Go Average Width of Stream using Mixing Length
B=Lgdavg0.13C(0.7C+2g)
​Go Average Depth of Stream given Length of Reach
davg=0.13B2C(0.7C+2g)Lg

How to Evaluate Constant Rate Injection Method or Plateau Gauging?

Constant Rate Injection Method or Plateau Gauging evaluator uses Constant Discharge Rate at C1 = Discharge in Stream*(Concentration Profile of Tracer at Section 2-Initial Concentration of Tracer)/(High Concentration of Tracer at Section 1-Concentration Profile of Tracer at Section 2) to evaluate the Constant Discharge Rate at C1, The Constant Rate Injection Method or Plateau Gauging formula is defined as the discharge when the tracer solution is introduced into the stream at a constant rate over time. The tracer concentration at points downstream rises asymptotically to a limiting, plateau value. Constant Discharge Rate at C1 is denoted by Qf symbol.

How to evaluate Constant Rate Injection Method or Plateau Gauging using this online evaluator? To use this online evaluator for Constant Rate Injection Method or Plateau Gauging, enter Discharge in Stream (Qs), Concentration Profile of Tracer at Section 2 (C2), Initial Concentration of Tracer (C0) & High Concentration of Tracer at Section 1 (C1) and hit the calculate button.

FAQs on Constant Rate Injection Method or Plateau Gauging

What is the formula to find Constant Rate Injection Method or Plateau Gauging?
The formula of Constant Rate Injection Method or Plateau Gauging is expressed as Constant Discharge Rate at C1 = Discharge in Stream*(Concentration Profile of Tracer at Section 2-Initial Concentration of Tracer)/(High Concentration of Tracer at Section 1-Concentration Profile of Tracer at Section 2). Here is an example- 20 = 60*(6-4)/(12-6).
How to calculate Constant Rate Injection Method or Plateau Gauging?
With Discharge in Stream (Qs), Concentration Profile of Tracer at Section 2 (C2), Initial Concentration of Tracer (C0) & High Concentration of Tracer at Section 1 (C1) we can find Constant Rate Injection Method or Plateau Gauging using the formula - Constant Discharge Rate at C1 = Discharge in Stream*(Concentration Profile of Tracer at Section 2-Initial Concentration of Tracer)/(High Concentration of Tracer at Section 1-Concentration Profile of Tracer at Section 2).
Can the Constant Rate Injection Method or Plateau Gauging be negative?
No, the Constant Rate Injection Method or Plateau Gauging, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Constant Rate Injection Method or Plateau Gauging?
Constant Rate Injection Method or Plateau Gauging is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Constant Rate Injection Method or Plateau Gauging can be measured.
Copied!