Constant Overhead AC is defined as the constant of line of a Overhead supply system. Check FAQs
K=4P2ρLPlossVac2
K - Constant Overhead AC?P - Power Transmitted?ρ - Resistivity?L - Length of Overhead AC Wire?Ploss - Line Losses?Vac - Voltage Overhead AC?

Constant (Single Phase Two Wire Mid-Point Earthed) Example

With values
With units
Only example

Here is how the Constant (Single Phase Two Wire Mid-Point Earthed) equation looks like with Values.

Here is how the Constant (Single Phase Two Wire Mid-Point Earthed) equation looks like with Units.

Here is how the Constant (Single Phase Two Wire Mid-Point Earthed) equation looks like.

0.0021Edit=4890Edit21.7E-5Edit10.63Edit8.23Edit180Edit2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Constant (Single Phase Two Wire Mid-Point Earthed)

Constant (Single Phase Two Wire Mid-Point Earthed) Solution

Follow our step by step solution on how to calculate Constant (Single Phase Two Wire Mid-Point Earthed)?

FIRST Step Consider the formula
K=4P2ρLPlossVac2
Next Step Substitute values of Variables
K=4890W21.7E-5Ω*m10.63m8.23W180V2
Next Step Prepare to Evaluate
K=489021.7E-510.638.231802
Next Step Evaluate
K=0.00214722396231793
LAST Step Rounding Answer
K=0.0021

Constant (Single Phase Two Wire Mid-Point Earthed) Formula Elements

Variables
Constant Overhead AC
Constant Overhead AC is defined as the constant of line of a Overhead supply system.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Voltage Overhead AC
Voltage Overhead AC is defined as the amount of work or force required to start the conduction of current within a line.
Symbol: Vac
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other Formulas to find Constant Overhead AC

​Go Constant using Load Current (Single Phase Two Wire Mid-Point OS)
K=8I2cos(Φ)2ρL2Ploss
​Go Constant using Line Losses (Single Phase Two Wire Mid-Point OS)
K=4ρP2L2PlossVm2

Other formulas in Wire Parameters category

​Go Area of X-Section(Single Phase Two Wire Mid-Point Earthed)
A=P2ρL((cos(Φ))2)PlossVac2
​Go Length of Wire using Area of X-Section(Single Phase Two Wire Mid-Point Earthed OS)
L=AVm2Plosscos(Φ)2ρP2
​Go Line Losses using Area of X-Section(Single Phase Two Wire Mid-Point Earthed OS)
Ploss=LρP2AVm2cos(Φ)2
​Go Area of X-Section using Load Current (Single Phase Two Wire Mid-Point OS)
A=2I2ρLPloss

How to Evaluate Constant (Single Phase Two Wire Mid-Point Earthed)?

Constant (Single Phase Two Wire Mid-Point Earthed) evaluator uses Constant Overhead AC = (4*Power Transmitted^2*Resistivity*Length of Overhead AC Wire)/(Line Losses*Voltage Overhead AC^2) to evaluate the Constant Overhead AC, The Constant (single Phase two Wire Mid-Point Earthed) formula is defined as the total constant of a single-phase two-wire overhead system. it is represented by K. Constant Overhead AC is denoted by K symbol.

How to evaluate Constant (Single Phase Two Wire Mid-Point Earthed) using this online evaluator? To use this online evaluator for Constant (Single Phase Two Wire Mid-Point Earthed), enter Power Transmitted (P), Resistivity (ρ), Length of Overhead AC Wire (L), Line Losses (Ploss) & Voltage Overhead AC (Vac) and hit the calculate button.

FAQs on Constant (Single Phase Two Wire Mid-Point Earthed)

What is the formula to find Constant (Single Phase Two Wire Mid-Point Earthed)?
The formula of Constant (Single Phase Two Wire Mid-Point Earthed) is expressed as Constant Overhead AC = (4*Power Transmitted^2*Resistivity*Length of Overhead AC Wire)/(Line Losses*Voltage Overhead AC^2). Here is an example- 0.002147 = (4*890^2*1.7E-05*10.63)/(8.23*180^2).
How to calculate Constant (Single Phase Two Wire Mid-Point Earthed)?
With Power Transmitted (P), Resistivity (ρ), Length of Overhead AC Wire (L), Line Losses (Ploss) & Voltage Overhead AC (Vac) we can find Constant (Single Phase Two Wire Mid-Point Earthed) using the formula - Constant Overhead AC = (4*Power Transmitted^2*Resistivity*Length of Overhead AC Wire)/(Line Losses*Voltage Overhead AC^2).
What are the other ways to Calculate Constant Overhead AC?
Here are the different ways to Calculate Constant Overhead AC-
  • Constant Overhead AC=(8*Current Overhead AC^2*cos(Phase Difference)^2*Resistivity*Length of Overhead AC Wire^2)/Line LossesOpenImg
  • Constant Overhead AC=(4*Resistivity*Power Transmitted^2*Length of Overhead AC Wire^2)/(Line Losses*Maximum Voltage Overhead AC^2)OpenImg
Copied!