Constant Overhead AC is defined as the constant of line of a Overhead supply system. Check FAQs
K=4(P2)ρLPloss(Vac2)
K - Constant Overhead AC?P - Power Transmitted?ρ - Resistivity?L - Length of Overhead AC Wire?Ploss - Line Losses?Vac - Voltage Overhead AC?

Constant(Single-Phase Two-Wire OS) Example

With values
With units
Only example

Here is how the Constant(Single-Phase Two-Wire OS) equation looks like with Values.

Here is how the Constant(Single-Phase Two-Wire OS) equation looks like with Units.

Here is how the Constant(Single-Phase Two-Wire OS) equation looks like.

0.0021Edit=4(890Edit2)1.7E-5Edit10.63Edit8.23Edit(180Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Constant(Single-Phase Two-Wire OS)

Constant(Single-Phase Two-Wire OS) Solution

Follow our step by step solution on how to calculate Constant(Single-Phase Two-Wire OS)?

FIRST Step Consider the formula
K=4(P2)ρLPloss(Vac2)
Next Step Substitute values of Variables
K=4(890W2)1.7E-5Ω*m10.63m8.23W(180V2)
Next Step Prepare to Evaluate
K=4(8902)1.7E-510.638.23(1802)
Next Step Evaluate
K=0.00214722396231793
LAST Step Rounding Answer
K=0.0021

Constant(Single-Phase Two-Wire OS) Formula Elements

Variables
Constant Overhead AC
Constant Overhead AC is defined as the constant of line of a Overhead supply system.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Voltage Overhead AC
Voltage Overhead AC is defined as the amount of work or force required to start the conduction of current within a line.
Symbol: Vac
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other Formulas to find Constant Overhead AC

​Go Constant using Load Current (Single-Phase Two-Wire OS)
K=2I2cos(Φ)2ρL2Ploss
​Go Constant using Line Losses (Single-Phase Two-Wire OS)
K=4ρ(PL)2Ploss(Vm)2

Other formulas in Wire Parameters category

​Go Line Losses(Single-Phase Two-Wire OS)
Ploss=(2)((I)2)R
​Go Area of X-Section(Single-Phase Two-Wire OS)
A=4(P2)ρL((cos(Φ))2)Ploss(Vac2)
​Go Volume of Conductor Material(Single-Phase Two-Wire OS)
V=2AL
​Go Length of Wire using Area of X-Section(Single-Phase Two-Wire OS)
L=AVm2Plosscos(Φ)24ρ(P2)

How to Evaluate Constant(Single-Phase Two-Wire OS)?

Constant(Single-Phase Two-Wire OS) evaluator uses Constant Overhead AC = (4*(Power Transmitted^2)*Resistivity*Length of Overhead AC Wire)/(Line Losses*(Voltage Overhead AC^2)) to evaluate the Constant Overhead AC, Constant(single-Phase two-Wire OS) formula is the total constant of a single-phase two-wire overhead system. it is represented by K. Constant Overhead AC is denoted by K symbol.

How to evaluate Constant(Single-Phase Two-Wire OS) using this online evaluator? To use this online evaluator for Constant(Single-Phase Two-Wire OS), enter Power Transmitted (P), Resistivity (ρ), Length of Overhead AC Wire (L), Line Losses (Ploss) & Voltage Overhead AC (Vac) and hit the calculate button.

FAQs on Constant(Single-Phase Two-Wire OS)

What is the formula to find Constant(Single-Phase Two-Wire OS)?
The formula of Constant(Single-Phase Two-Wire OS) is expressed as Constant Overhead AC = (4*(Power Transmitted^2)*Resistivity*Length of Overhead AC Wire)/(Line Losses*(Voltage Overhead AC^2)). Here is an example- 0.002147 = (4*(890^2)*1.7E-05*10.63)/(8.23*(180^2)).
How to calculate Constant(Single-Phase Two-Wire OS)?
With Power Transmitted (P), Resistivity (ρ), Length of Overhead AC Wire (L), Line Losses (Ploss) & Voltage Overhead AC (Vac) we can find Constant(Single-Phase Two-Wire OS) using the formula - Constant Overhead AC = (4*(Power Transmitted^2)*Resistivity*Length of Overhead AC Wire)/(Line Losses*(Voltage Overhead AC^2)).
What are the other ways to Calculate Constant Overhead AC?
Here are the different ways to Calculate Constant Overhead AC-
  • Constant Overhead AC=(2*Current Overhead AC^2*cos(Phase Difference)^2*Resistivity*Length of Overhead AC Wire^2)/Line LossesOpenImg
  • Constant Overhead AC=(4*Resistivity*(Power Transmitted*Length of Overhead AC Wire)^2)/(Line Losses*(Maximum Voltage Overhead AC)^2)OpenImg
Copied!