Constant Overhead AC is defined as the constant of line of a Overhead supply system. Check FAQs
K=4(P2)ρ(L2)Ploss(Vm2)
K - Constant Overhead AC?P - Power Transmitted?ρ - Resistivity?L - Length of Overhead AC Wire?Ploss - Line Losses?Vm - Maximum Voltage Overhead AC?

Constant(3-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Constant(3-Phase 4-Wire OS) equation looks like with Values.

Here is how the Constant(3-Phase 4-Wire OS) equation looks like with Units.

Here is how the Constant(3-Phase 4-Wire OS) equation looks like.

0.1924Edit=4(890Edit2)1.7E-5Edit(10.63Edit2)8.23Edit(62Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Constant(3-Phase 4-Wire OS)

Constant(3-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Constant(3-Phase 4-Wire OS)?

FIRST Step Consider the formula
K=4(P2)ρ(L2)Ploss(Vm2)
Next Step Substitute values of Variables
K=4(890W2)1.7E-5Ω*m(10.63m2)8.23W(62V2)
Next Step Prepare to Evaluate
K=4(8902)1.7E-5(10.632)8.23(622)
Next Step Evaluate
K=0.192385457676858
LAST Step Rounding Answer
K=0.1924

Constant(3-Phase 4-Wire OS) Formula Elements

Variables
Constant Overhead AC
Constant Overhead AC is defined as the constant of line of a Overhead supply system.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage Overhead AC
Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.

Other Formulas to find Constant Overhead AC

​Go Constant using Volume of Conductor Material (3-Phase 4-Wire OS)
K=V(cos(Φ))20.583

Other formulas in Wire Parameters category

​Go Area of X-Section(3-Phase 4-Wire OS)
A=2(P2)ρL((cos(Φ))2)Ploss3(Vm2)
​Go Line Losses(3-Phase 4-Wire OS)
Ploss=(3)((I)2)R
​Go Volume of Conductor Material(3-Phase 4-Wire OS)
V=(3.5)AL
​Go Length of Wire using Area of X-Section(3-Phase 4-Wire OS)
L=3A(Vm2)Ploss(cos(Φ))22ρ(P2)

How to Evaluate Constant(3-Phase 4-Wire OS)?

Constant(3-Phase 4-Wire OS) evaluator uses Constant Overhead AC = (4*(Power Transmitted^2)*Resistivity*(Length of Overhead AC Wire^2))/(Line Losses*(Maximum Voltage Overhead AC^2)) to evaluate the Constant Overhead AC, The Constant(3-Phase 4-Wire OS) formula is the total constant of a single-phase two-wire overhead system. it is represented by K. Constant Overhead AC is denoted by K symbol.

How to evaluate Constant(3-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Constant(3-Phase 4-Wire OS), enter Power Transmitted (P), Resistivity (ρ), Length of Overhead AC Wire (L), Line Losses (Ploss) & Maximum Voltage Overhead AC (Vm) and hit the calculate button.

FAQs on Constant(3-Phase 4-Wire OS)

What is the formula to find Constant(3-Phase 4-Wire OS)?
The formula of Constant(3-Phase 4-Wire OS) is expressed as Constant Overhead AC = (4*(Power Transmitted^2)*Resistivity*(Length of Overhead AC Wire^2))/(Line Losses*(Maximum Voltage Overhead AC^2)). Here is an example- 0.192385 = (4*(890^2)*1.7E-05*(10.63^2))/(8.23*(62^2)).
How to calculate Constant(3-Phase 4-Wire OS)?
With Power Transmitted (P), Resistivity (ρ), Length of Overhead AC Wire (L), Line Losses (Ploss) & Maximum Voltage Overhead AC (Vm) we can find Constant(3-Phase 4-Wire OS) using the formula - Constant Overhead AC = (4*(Power Transmitted^2)*Resistivity*(Length of Overhead AC Wire^2))/(Line Losses*(Maximum Voltage Overhead AC^2)).
What are the other ways to Calculate Constant Overhead AC?
Here are the different ways to Calculate Constant Overhead AC-
  • Constant Overhead AC=Volume of Conductor*(cos(Phase Difference))^2/(0.583)OpenImg
Copied!