Fx Copy
LaTeX Copy
Discharge is the flow rate of water that is extracted from or injected into a well. Check FAQs
Q=2.72TenviStwlog((Rwr),10)
Q - Discharge?Tenvi - Coefficient of Transmissibility?Stw - Total Drawdown in Well?Rw - Radius of Influence?r - Radius of Well?

Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility Example

With values
With units
Only example

Here is how the Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility equation looks like with Values.

Here is how the Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility equation looks like with Units.

Here is how the Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility equation looks like.

1.1955Edit=2.721.5Edit4.93Editlog((8.6Edit7.5Edit),10)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility

Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility Solution

Follow our step by step solution on how to calculate Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility?

FIRST Step Consider the formula
Q=2.72TenviStwlog((Rwr),10)
Next Step Substitute values of Variables
Q=2.721.5m²/s4.93mlog((8.6m7.5m),10)
Next Step Prepare to Evaluate
Q=2.721.54.93log((8.67.5),10)
Next Step Evaluate
Q=1.19554337132761m³/s
LAST Step Rounding Answer
Q=1.1955m³/s

Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility Formula Elements

Variables
Functions
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Coefficient of Transmissibility
Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Symbol: Tenvi
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Total Drawdown in Well
Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Symbol: Stw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Influence
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Symbol: Rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Well
Radius of Well is defined as the distance from center of well to its outer boundary.
Symbol: r
Measurement: LengthUnit: m
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Discharge

​Go Discharge in Confined Aquifer with Base 10
Q=2.72Kwbw(Hi-hw)log((Rwr),10)
​Go Confined Aquifer Discharge given Drawdown at Well
Q=2πKWHbpStwlog((Rwr),e)
​Go Confined Aquifer Discharge with Base 10 given Drawdown at Well
Q=2.72KWHbwStwlog((Rwr),10)
​Go Confined Aquifer Discharge given Coefficient of Transmissibility
Q=2πTenvistlog((Rwr),e)

Other formulas in Aquifer Discharge category

​Go Discharge in Confined Aquifer
Qc=2πKWHbw(Hi-hw)log((Rwr),e)
​Go Discharge in Confined Aquifer given Coefficient of Transmissibility
Qct=2πTw(Hi-hw)log((Rwr),e)
​Go Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility
Qc=2.72Tw(Hi-hw)log((Rwr),10)
​Go Confined Aquifer Discharge given Depth of Water in Two Wells
Qcaq=2.72Kwbp(h2-h1)log((r2r1),10)

How to Evaluate Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility?

Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility evaluator uses Discharge = (2.72*Coefficient of Transmissibility*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10)) to evaluate the Discharge, The Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility formula is defined as the value of discharge in the aquifer when we have prior information of coefficient of transmissibility. Discharge is denoted by Q symbol.

How to evaluate Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility using this online evaluator? To use this online evaluator for Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility, enter Coefficient of Transmissibility (Tenvi), Total Drawdown in Well (Stw), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button.

FAQs on Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility

What is the formula to find Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility?
The formula of Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility is expressed as Discharge = (2.72*Coefficient of Transmissibility*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10)). Here is an example- 1.195543 = (2.72*1.5*4.93)/(log((8.6/7.5),10)).
How to calculate Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility?
With Coefficient of Transmissibility (Tenvi), Total Drawdown in Well (Stw), Radius of Influence (Rw) & Radius of Well (r) we can find Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility using the formula - Discharge = (2.72*Coefficient of Transmissibility*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10)). This formula also uses Logarithmic Inverse Function function(s).
What are the other ways to Calculate Discharge?
Here are the different ways to Calculate Discharge-
  • Discharge=(2.72*Coefficient of Permeability*Aquifer Thickness*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))OpenImg
  • Discharge=(2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),e))OpenImg
  • Discharge=(2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))OpenImg
Can the Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility be negative?
Yes, the Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility?
Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Confined Aquifer Discharge with Base 10 given Coefficient of Transmissibility can be measured.
Copied!