Fx Copy
LaTeX Copy
Discharge is the flow rate of water that is extracted from or injected into a well. Check FAQs
Q=2.72Tw(h2-h1)log((r2r1),10)
Q - Discharge?Tw - Coefficient of Transmissibility in Enviro. Eng.?h2 - Depth of Water 2?h1 - Depth of Water 1?r2 - Radial Distance at Observation Well 2?r1 - Radial Distance at Observation Well 1?

Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water Example

With values
With units
Only example

Here is how the Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water equation looks like with Values.

Here is how the Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water equation looks like with Units.

Here is how the Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water equation looks like.

1.0227Edit=2.7226.9Edit(17.8644Edit-17.85Edit)log((10Edit1.07Edit),10)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water

Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water Solution

Follow our step by step solution on how to calculate Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water?

FIRST Step Consider the formula
Q=2.72Tw(h2-h1)log((r2r1),10)
Next Step Substitute values of Variables
Q=2.7226.9m²/s(17.8644m-17.85m)log((10m1.07m),10)
Next Step Prepare to Evaluate
Q=2.7226.9(17.8644-17.85)log((101.07),10)
Next Step Evaluate
Q=1.02265988766222m³/s
LAST Step Rounding Answer
Q=1.0227m³/s

Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water Formula Elements

Variables
Functions
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Coefficient of Transmissibility in Enviro. Eng.
Coefficient of Transmissibility in Enviro. Eng. is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Symbol: Tw
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Depth of Water 2
Depth of water 2 means the depth of the water in 2nd well.
Symbol: h2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Depth of Water 1
Depth of Water 1 is the depth of water in the 1st considered well.
Symbol: h1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radial Distance at Observation Well 2
Radial Distance at Observation Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used.
Symbol: r2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Radial Distance at Observation Well 1
Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
Symbol: r1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Discharge

​Go Discharge in Confined Aquifer with Base 10
Q=2.72Kwbw(Hi-hw)log((Rwr),10)
​Go Confined Aquifer Discharge given Drawdown at Well
Q=2πKWHbpStwlog((Rwr),e)
​Go Confined Aquifer Discharge with Base 10 given Drawdown at Well
Q=2.72KWHbwStwlog((Rwr),10)
​Go Confined Aquifer Discharge given Coefficient of Transmissibility
Q=2πTenvistlog((Rwr),e)

Other formulas in Aquifer Discharge category

​Go Discharge in Confined Aquifer
Qc=2πKWHbw(Hi-hw)log((Rwr),e)
​Go Discharge in Confined Aquifer given Coefficient of Transmissibility
Qct=2πTw(Hi-hw)log((Rwr),e)
​Go Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility
Qc=2.72Tw(Hi-hw)log((Rwr),10)
​Go Confined Aquifer Discharge given Depth of Water in Two Wells
Qcaq=2.72Kwbp(h2-h1)log((r2r1),10)

How to Evaluate Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water?

Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water evaluator uses Discharge = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)) to evaluate the Discharge, The Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water formula is defined as the value of confined aquifer discharge when we have prior information of coefficient of transmissibility and depth of water. Discharge is denoted by Q symbol.

How to evaluate Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water using this online evaluator? To use this online evaluator for Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water, enter Coefficient of Transmissibility in Enviro. Eng. (Tw), Depth of Water 2 (h2), Depth of Water 1 (h1), Radial Distance at Observation Well 2 (r2) & Radial Distance at Observation Well 1 (r1) and hit the calculate button.

FAQs on Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water

What is the formula to find Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water?
The formula of Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water is expressed as Discharge = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)). Here is an example- 1.02266 = (2.72*26.9*(17.8644-17.85))/(log((10/1.07),10)).
How to calculate Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water?
With Coefficient of Transmissibility in Enviro. Eng. (Tw), Depth of Water 2 (h2), Depth of Water 1 (h1), Radial Distance at Observation Well 2 (r2) & Radial Distance at Observation Well 1 (r1) we can find Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water using the formula - Discharge = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)). This formula also uses Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Discharge?
Here are the different ways to Calculate Discharge-
  • Discharge=(2.72*Coefficient of Permeability*Aquifer Thickness*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))OpenImg
  • Discharge=(2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),e))OpenImg
  • Discharge=(2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))OpenImg
Can the Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water be negative?
Yes, the Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water?
Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water can be measured.
Copied!