Concentration of Stationary Phase given Capacity Factor Formula

Fx Copy
LaTeX Copy
The Concentration of stationary phase is the application of the motionless part of the chromatography column. Check FAQs
Cs=CmVmobile phasek'Vs
Cs - Concentration of Stationary Phase?Cm - Concentration of Mobile Phase?Vmobile phase - Volume of Mobile Phase?k' - Capacity Factor?Vs - Volume of Stationary Phase?

Concentration of Stationary Phase given Capacity Factor Example

With values
With units
Only example

Here is how the Concentration of Stationary Phase given Capacity Factor equation looks like with Values.

Here is how the Concentration of Stationary Phase given Capacity Factor equation looks like with Units.

Here is how the Concentration of Stationary Phase given Capacity Factor equation looks like.

12.8571Edit=6Edit5Edit3Edit7Edit
You are here -
HomeIcon Home » Category Chemistry » Category Analytical chemistry » Category Method of Separation Technique » fx Concentration of Stationary Phase given Capacity Factor

Concentration of Stationary Phase given Capacity Factor Solution

Follow our step by step solution on how to calculate Concentration of Stationary Phase given Capacity Factor?

FIRST Step Consider the formula
Cs=CmVmobile phasek'Vs
Next Step Substitute values of Variables
Cs=6mol/L5L37L
Next Step Convert Units
Cs=6000mol/m³0.00530.007
Next Step Prepare to Evaluate
Cs=60000.00530.007
Next Step Evaluate
Cs=12857.1428571429mol/m³
Next Step Convert to Output's Unit
Cs=12.8571428571429mol/L
LAST Step Rounding Answer
Cs=12.8571mol/L

Concentration of Stationary Phase given Capacity Factor Formula Elements

Variables
Concentration of Stationary Phase
The Concentration of stationary phase is the application of the motionless part of the chromatography column.
Symbol: Cs
Measurement: Molar ConcentrationUnit: mol/L
Note: Value can be positive or negative.
Concentration of Mobile Phase
The Concentration of Mobile Phase is the application of a solution that runs through the column.
Symbol: Cm
Measurement: Molar ConcentrationUnit: mol/L
Note: Value can be positive or negative.
Volume of Mobile Phase
The Volume of Mobile Phase is the amount of the solvent that runs through the chromatography column.
Symbol: Vmobile phase
Measurement: VolumeUnit: L
Note: Value can be positive or negative.
Capacity Factor
The Capacity factor is directly proportional to the retention factor. The longer a component is retained by the column, the greater is the capacity factor.
Symbol: k'
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Volume of Stationary Phase
The Volume of Stationary Phase is the amount of motionless part of the chromatography column.
Symbol: Vs
Measurement: VolumeUnit: L
Note: Value can be positive or negative.

Other formulas in Volume and Concentration of Mobile and Stationary Phase category

​Go Volume of Stationary Phase given Capacity Factor
Vs=Vmobile phaseCmk'Cs
​Go Volume of Mobile Phase given Capacity Factor
Vmobile phase=VsCsk'Cm
​Go Volume of Stationary Phase given Capacity Factor and Partition Coefficient
Vs=k'Vmobile phaseK
​Go Volume of Mobile Phase given Capacity Factor and Partition Coefficient
Vmobile phase=K(Vsk')

How to Evaluate Concentration of Stationary Phase given Capacity Factor?

Concentration of Stationary Phase given Capacity Factor evaluator uses Concentration of Stationary Phase = (Concentration of Mobile Phase*Volume of Mobile Phase*Capacity Factor)/Volume of Stationary Phase to evaluate the Concentration of Stationary Phase, The Concentration of stationary phase given capacity factor formula is defined as the ratio of concentration and volume of mobile phase and capacity factor to the volume of stationary phase. Concentration of Stationary Phase is denoted by Cs symbol.

How to evaluate Concentration of Stationary Phase given Capacity Factor using this online evaluator? To use this online evaluator for Concentration of Stationary Phase given Capacity Factor, enter Concentration of Mobile Phase (Cm), Volume of Mobile Phase (Vmobile phase), Capacity Factor (k') & Volume of Stationary Phase (Vs) and hit the calculate button.

FAQs on Concentration of Stationary Phase given Capacity Factor

What is the formula to find Concentration of Stationary Phase given Capacity Factor?
The formula of Concentration of Stationary Phase given Capacity Factor is expressed as Concentration of Stationary Phase = (Concentration of Mobile Phase*Volume of Mobile Phase*Capacity Factor)/Volume of Stationary Phase. Here is an example- 0.012857 = (6000*0.005*3)/0.007.
How to calculate Concentration of Stationary Phase given Capacity Factor?
With Concentration of Mobile Phase (Cm), Volume of Mobile Phase (Vmobile phase), Capacity Factor (k') & Volume of Stationary Phase (Vs) we can find Concentration of Stationary Phase given Capacity Factor using the formula - Concentration of Stationary Phase = (Concentration of Mobile Phase*Volume of Mobile Phase*Capacity Factor)/Volume of Stationary Phase.
Can the Concentration of Stationary Phase given Capacity Factor be negative?
Yes, the Concentration of Stationary Phase given Capacity Factor, measured in Molar Concentration can be negative.
Which unit is used to measure Concentration of Stationary Phase given Capacity Factor?
Concentration of Stationary Phase given Capacity Factor is usually measured using the Mole per Liter[mol/L] for Molar Concentration. Mole per Cubic Meter[mol/L], Mole per Cubic Millimeter[mol/L], Kilomole per Cubic Meter[mol/L] are the few other units in which Concentration of Stationary Phase given Capacity Factor can be measured.
Copied!