Compression or Expansion Ratio Formula

Fx Copy
LaTeX Copy
Compression or Expansion Ratio is the ratio of the volume of air before compression or expansion to the volume after compression or expansion in air refrigeration. Check FAQs
rp=P2P1
rp - Compression or Expansion Ratio?P2 - Pressure at End of Isentropic Compression?P1 - Pressure at Start of Isentropic Compression?

Compression or Expansion Ratio Example

With values
With units
Only example

Here is how the Compression or Expansion Ratio equation looks like with Values.

Here is how the Compression or Expansion Ratio equation looks like with Units.

Here is how the Compression or Expansion Ratio equation looks like.

25Edit=1E+7Edit400000Edit
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Refrigeration and Air Conditioning » fx Compression or Expansion Ratio

Compression or Expansion Ratio Solution

Follow our step by step solution on how to calculate Compression or Expansion Ratio?

FIRST Step Consider the formula
rp=P2P1
Next Step Substitute values of Variables
rp=1E+7Pa400000Pa
Next Step Prepare to Evaluate
rp=1E+7400000
LAST Step Evaluate
rp=25

Compression or Expansion Ratio Formula Elements

Variables
Compression or Expansion Ratio
Compression or Expansion Ratio is the ratio of the volume of air before compression or expansion to the volume after compression or expansion in air refrigeration.
Symbol: rp
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Pressure at End of Isentropic Compression
Pressure at End of Isentropic Compression is the final pressure achieved at the end of the isentropic compression process in an air refrigeration system.
Symbol: P2
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.
Pressure at Start of Isentropic Compression
Pressure at Start of Isentropic Compression is the initial pressure of the refrigerant at the beginning of the isentropic compression process in an air refrigeration system.
Symbol: P1
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.

Other formulas in Air Refrigeration Cycles category

​Go Energy Performance Ratio of Heat Pump
COPtheoretical=QdeliveredWper min
​Go Relative Coefficient of Performance
COPrelative=COPactualCOPtheoretical
​Go Theoretical Coefficient of Performance of Refrigerator
COPtheoretical=Qrefw
​Go COP of Bell-Coleman Cycle for given Compression Ratio and Adiabatic Index
COPtheoretical=1rpγ-1γ-1

How to Evaluate Compression or Expansion Ratio?

Compression or Expansion Ratio evaluator uses Compression or Expansion Ratio = Pressure at End of Isentropic Compression/Pressure at Start of Isentropic Compression to evaluate the Compression or Expansion Ratio, Compression or Expansion Ratio formula is defined as the ratio of the discharge pressure to the suction pressure of a refrigerant in a refrigeration system, used to measure the performance of a compressor or an expander in refrigeration and air conditioning systems. Compression or Expansion Ratio is denoted by rp symbol.

How to evaluate Compression or Expansion Ratio using this online evaluator? To use this online evaluator for Compression or Expansion Ratio, enter Pressure at End of Isentropic Compression (P2) & Pressure at Start of Isentropic Compression (P1) and hit the calculate button.

FAQs on Compression or Expansion Ratio

What is the formula to find Compression or Expansion Ratio?
The formula of Compression or Expansion Ratio is expressed as Compression or Expansion Ratio = Pressure at End of Isentropic Compression/Pressure at Start of Isentropic Compression. Here is an example- 25 = 10000000/400000.
How to calculate Compression or Expansion Ratio?
With Pressure at End of Isentropic Compression (P2) & Pressure at Start of Isentropic Compression (P1) we can find Compression or Expansion Ratio using the formula - Compression or Expansion Ratio = Pressure at End of Isentropic Compression/Pressure at Start of Isentropic Compression.
Copied!