Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket Formula

Fx Copy
LaTeX Copy
Combined stiffness for gasket joint is the combined values of stiffness of cylinder cover, cylinder flange, and gasket. Check FAQs
kc=1(1k1)+(1k2)+(1kg)
kc - Combined Stiffness for Gasket Joint?k1 - Stiffness of Pressurized Cylinder Cover?k2 - Stiffness of Pressurized Cylinder Flange?kg - Stiffness of Gasket?

Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket Example

With values
With units
Only example

Here is how the Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket equation looks like with Values.

Here is how the Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket equation looks like with Units.

Here is how the Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket equation looks like.

4721.1054Edit=1(110050Edit)+(111100Edit)+(145000Edit)
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Machine Design » fx Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket

Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket Solution

Follow our step by step solution on how to calculate Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket?

FIRST Step Consider the formula
kc=1(1k1)+(1k2)+(1kg)
Next Step Substitute values of Variables
kc=1(110050kN/mm)+(111100kN/mm)+(145000kN/mm)
Next Step Convert Units
kc=1(11E+10N/m)+(11.1E+10N/m)+(14.5E+10N/m)
Next Step Prepare to Evaluate
kc=1(11E+10)+(11.1E+10)+(14.5E+10)
Next Step Evaluate
kc=4721105421.30433N/m
Next Step Convert to Output's Unit
kc=4721.10542130433kN/mm
LAST Step Rounding Answer
kc=4721.1054kN/mm

Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket Formula Elements

Variables
Combined Stiffness for Gasket Joint
Combined stiffness for gasket joint is the combined values of stiffness of cylinder cover, cylinder flange, and gasket.
Symbol: kc
Measurement: Stiffness ConstantUnit: kN/mm
Note: Value should be greater than 0.
Stiffness of Pressurized Cylinder Cover
Stiffness of pressurized cylinder cover is the amount of force required to extend a cylinder cover by unit length.
Symbol: k1
Measurement: Stiffness ConstantUnit: kN/mm
Note: Value should be greater than 0.
Stiffness of Pressurized Cylinder Flange
Stiffness of pressurized cylinder flange is the amount of force required to extend a cylinder flange by unit length.
Symbol: k2
Measurement: Stiffness ConstantUnit: kN/mm
Note: Value should be greater than 0.
Stiffness of Gasket
The Stiffness of Gasket Value is the amount of force required to extend a gasket by unit length.
Symbol: kg
Measurement: Stiffness ConstantUnit: kN/mm
Note: Value should be greater than 0.

Other formulas in Gasket Joint category

​Go Stiffness of Bolt of Gasket Joint given Nominal Diameter, Total Thickness, and Young's Modulus
kb=(πd24)(El)
​Go Nominal Diameter of Gasket Joint Bolt given Stiffness, total thickness and Young's Modulus
d=kb4lπE
​Go Total Thickness of Gasket Joint given Stiffness, Nominal Diameter and Young's Modulus
l=(πd24)(Ekb)
​Go Young's Modulus of Gasket Joint given Stiffness, Total Thickness and Nominal Diameter
E=kblπd24

How to Evaluate Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket?

Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket evaluator uses Combined Stiffness for Gasket Joint = 1/((1/Stiffness of Pressurized Cylinder Cover)+(1/Stiffness of Pressurized Cylinder Flange)+(1/Stiffness of Gasket)) to evaluate the Combined Stiffness for Gasket Joint, The Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket formula is defined as the total or the net stiffness of Cylinder Cover, Cylinder Flange and Gasket. Combined Stiffness for Gasket Joint is denoted by kc symbol.

How to evaluate Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket using this online evaluator? To use this online evaluator for Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket, enter Stiffness of Pressurized Cylinder Cover (k1), Stiffness of Pressurized Cylinder Flange (k2) & Stiffness of Gasket (kg) and hit the calculate button.

FAQs on Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket

What is the formula to find Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket?
The formula of Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket is expressed as Combined Stiffness for Gasket Joint = 1/((1/Stiffness of Pressurized Cylinder Cover)+(1/Stiffness of Pressurized Cylinder Flange)+(1/Stiffness of Gasket)). Here is an example- 0.004721 = 1/((1/10050000000)+(1/11100000000)+(1/45000000000)).
How to calculate Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket?
With Stiffness of Pressurized Cylinder Cover (k1), Stiffness of Pressurized Cylinder Flange (k2) & Stiffness of Gasket (kg) we can find Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket using the formula - Combined Stiffness for Gasket Joint = 1/((1/Stiffness of Pressurized Cylinder Cover)+(1/Stiffness of Pressurized Cylinder Flange)+(1/Stiffness of Gasket)).
Can the Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket be negative?
No, the Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket, measured in Stiffness Constant cannot be negative.
Which unit is used to measure Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket?
Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket is usually measured using the Kilonewton per Millimeter[kN/mm] for Stiffness Constant. Newton per Meter[kN/mm], Newton per Millimeter[kN/mm] are the few other units in which Combined Stiffness of Cylinder Cover, Cylinder Flange and Gasket can be measured.
Copied!