Collector efficiency factor Formula

Fx Copy
LaTeX Copy
Collector Efficiency Factor is the ratio of the energy gained by the air to the energy received by the collector in a solar air heater system. Check FAQs
F′=(1+Ulhe)-1
F′ - Collector Efficiency Factor?Ul - Overall Loss Coefficient?he - Effective Heat Transfer Coefficient?

Collector efficiency factor Example

With values
With units
Only example

Here is how the Collector efficiency factor equation looks like with Values.

Here is how the Collector efficiency factor equation looks like with Units.

Here is how the Collector efficiency factor equation looks like.

0.8107Edit=(1+1.25Edit5.3527Edit)-1
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Solar Energy Systems » fx Collector efficiency factor

Collector efficiency factor Solution

Follow our step by step solution on how to calculate Collector efficiency factor?

FIRST Step Consider the formula
F′=(1+Ulhe)-1
Next Step Substitute values of Variables
F′=(1+1.25W/m²*K5.3527W/m²*K)-1
Next Step Prepare to Evaluate
F′=(1+1.255.3527)-1
Next Step Evaluate
F′=0.810682963481047
LAST Step Rounding Answer
F′=0.8107

Collector efficiency factor Formula Elements

Variables
Collector Efficiency Factor
Collector Efficiency Factor is the ratio of the energy gained by the air to the energy received by the collector in a solar air heater system.
Symbol: F′
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Overall Loss Coefficient
Overall loss coefficient is defined as the heat loss from collector per unit area of absorber plate and temperature difference between absorber plate and surrounding air.
Symbol: Ul
Measurement: Heat Transfer CoefficientUnit: W/m²*K
Note: Value should be greater than 0.
Effective Heat Transfer Coefficient
Effective Heat Transfer Coefficient is the rate of heat transfer between the solar air heater and the surrounding air, affecting its overall performance.
Symbol: he
Measurement: Heat Transfer CoefficientUnit: W/m²*K
Note: Value can be positive or negative.

Other formulas in Solar Air Heater category

​Go Equivalent radiative heat transfer coefficient
hr=4[Stefan-BoltZ](Tpm+Tbm)3(1εp)+(1εb)-1(8)
​Go Effective heat transfer coefficient
he=hfp+hrhfbhr+hfb
​Go Effective heat transfer coefficient for variation
he=hfp(1+2LfΦfhffWhfp)+hrhfbhr+hfb
​Go Incident flux when flow is between Cover and Absorber plate
Sflux=hfp(Tpm-Tfi)+(hr(Tpm-Tc))+(Ub(Tpm-Ta))

How to Evaluate Collector efficiency factor?

Collector efficiency factor evaluator uses Collector Efficiency Factor = (1+Overall Loss Coefficient/Effective Heat Transfer Coefficient)^-1 to evaluate the Collector Efficiency Factor, Collector efficiency factor formula is defined as a dimensionless quantity that characterizes the thermal performance of a solar air heater, representing the ratio of actual heat gain to the maximum possible heat gain, thereby indicating the effectiveness of the collector in harnessing solar energy. Collector Efficiency Factor is denoted by F′ symbol.

How to evaluate Collector efficiency factor using this online evaluator? To use this online evaluator for Collector efficiency factor, enter Overall Loss Coefficient (Ul) & Effective Heat Transfer Coefficient (he) and hit the calculate button.

FAQs on Collector efficiency factor

What is the formula to find Collector efficiency factor?
The formula of Collector efficiency factor is expressed as Collector Efficiency Factor = (1+Overall Loss Coefficient/Effective Heat Transfer Coefficient)^-1. Here is an example- 0.810683 = (1+1.25/5.352681)^-1.
How to calculate Collector efficiency factor?
With Overall Loss Coefficient (Ul) & Effective Heat Transfer Coefficient (he) we can find Collector efficiency factor using the formula - Collector Efficiency Factor = (1+Overall Loss Coefficient/Effective Heat Transfer Coefficient)^-1.