Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer. Check FAQs
Tenvi=Q2.72(bw-hwell)log((Rwr),10)
Tenvi - Coefficient of Transmissibility?Q - Discharge?bw - Aquifer Thickness?hwell - Depth of Water in Well?Rw - Radius of Influence?r - Radius of Well?

Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 Example

With values
With units
Only example

Here is how the Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 equation looks like with Values.

Here is how the Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 equation looks like with Units.

Here is how the Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 equation looks like.

1.5054Edit=1.01Edit2.72(14.15Edit-10Edit)log((8.6Edit7.5Edit),10)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10

Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 Solution

Follow our step by step solution on how to calculate Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10?

FIRST Step Consider the formula
Tenvi=Q2.72(bw-hwell)log((Rwr),10)
Next Step Substitute values of Variables
Tenvi=1.01m³/s2.72(14.15m-10m)log((8.6m7.5m),10)
Next Step Prepare to Evaluate
Tenvi=1.012.72(14.15-10)log((8.67.5),10)
Next Step Evaluate
Tenvi=1.50537992273191m²/s
LAST Step Rounding Answer
Tenvi=1.5054m²/s

Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 Formula Elements

Variables
Functions
Coefficient of Transmissibility
Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Symbol: Tenvi
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Aquifer Thickness
Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Symbol: bw
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Depth of Water in Well
Depth of Water in Well is measured above the impermeable layer.
Symbol: hwell
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Radius of Influence
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Symbol: Rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Well
Radius of Well is defined as the distance from center of well to its outer boundary.
Symbol: r
Measurement: LengthUnit: m
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Coefficient of Transmissibility

​Go Coefficient of Transmissibility given Confined Aquifer Discharge
Tenvi=Q2πstlog((Rwr),e)
​Go Coefficient of Transmissibility given Depth of Water in Two Wells
Tenvi=Q2.72(h2-h1)log((r2r1'),10)

How to Evaluate Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10?

Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 evaluator uses Coefficient of Transmissibility = Discharge/((2.72*(Aquifer Thickness-Depth of Water in Well))/(log((Radius of Influence/Radius of Well),10))) to evaluate the Coefficient of Transmissibility, The Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 formula is defined as the value of coefficient of transmissibility when we have prior information of discharge in confined aquifer. Coefficient of Transmissibility is denoted by Tenvi symbol.

How to evaluate Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 using this online evaluator? To use this online evaluator for Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10, enter Discharge (Q), Aquifer Thickness (bw), Depth of Water in Well (hwell), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button.

FAQs on Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10

What is the formula to find Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10?
The formula of Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 is expressed as Coefficient of Transmissibility = Discharge/((2.72*(Aquifer Thickness-Depth of Water in Well))/(log((Radius of Influence/Radius of Well),10))). Here is an example- 1.249465 = 1.01/((2.72*(14.15-10))/(log((8.6/7.5),10))).
How to calculate Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10?
With Discharge (Q), Aquifer Thickness (bw), Depth of Water in Well (hwell), Radius of Influence (Rw) & Radius of Well (r) we can find Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 using the formula - Coefficient of Transmissibility = Discharge/((2.72*(Aquifer Thickness-Depth of Water in Well))/(log((Radius of Influence/Radius of Well),10))). This formula also uses Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Coefficient of Transmissibility?
Here are the different ways to Calculate Coefficient of Transmissibility-
  • Coefficient of Transmissibility=Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e)))OpenImg
  • Coefficient of Transmissibility=Discharge/((2.72*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Well 1),10)))OpenImg
Can the Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 be negative?
No, the Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10, measured in Kinematic Viscosity cannot be negative.
Which unit is used to measure Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10?
Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 is usually measured using the Square Meter per Second[m²/s] for Kinematic Viscosity. Square Meter per Hour[m²/s], Square Centimeter per Second[m²/s], Square Millimeter per Second[m²/s] are the few other units in which Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10 can be measured.
Copied!