Fx Copy
LaTeX Copy
Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer. Check FAQs
Tenvi=Q2.72(h2-h1)log((r2r1'),10)
Tenvi - Coefficient of Transmissibility?Q - Discharge?h2 - Depth of Water 2?h1 - Depth of Water 1?r2 - Radial Distance at Observation Well 2?r1' - Radial Distance at Well 1?

Coefficient of Transmissibility given Depth of Water in Two Wells Example

With values
With units
Only example

Here is how the Coefficient of Transmissibility given Depth of Water in Two Wells equation looks like with Values.

Here is how the Coefficient of Transmissibility given Depth of Water in Two Wells equation looks like with Units.

Here is how the Coefficient of Transmissibility given Depth of Water in Two Wells equation looks like.

2.5786Edit=1.01Edit2.72(17.8644Edit-17.85Edit)log((10Edit1E-9Edit),10)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Coefficient of Transmissibility given Depth of Water in Two Wells

Coefficient of Transmissibility given Depth of Water in Two Wells Solution

Follow our step by step solution on how to calculate Coefficient of Transmissibility given Depth of Water in Two Wells?

FIRST Step Consider the formula
Tenvi=Q2.72(h2-h1)log((r2r1'),10)
Next Step Substitute values of Variables
Tenvi=1.01m³/s2.72(17.8644m-17.85m)log((10m1E-9m),10)
Next Step Prepare to Evaluate
Tenvi=1.012.72(17.8644-17.85)log((101E-9),10)
Next Step Evaluate
Tenvi=2.57863562091532m²/s
LAST Step Rounding Answer
Tenvi=2.5786m²/s

Coefficient of Transmissibility given Depth of Water in Two Wells Formula Elements

Variables
Functions
Coefficient of Transmissibility
Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Symbol: Tenvi
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Depth of Water 2
Depth of water 2 means the depth of the water in 2nd well.
Symbol: h2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Depth of Water 1
Depth of Water 1 is the depth of water in the 1st considered well.
Symbol: h1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radial Distance at Observation Well 2
Radial Distance at Observation Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used.
Symbol: r2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Radial Distance at Well 1
Radial Distance at Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
Symbol: r1'
Measurement: LengthUnit: m
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Coefficient of Transmissibility

​Go Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10
Tenvi=Q2.72(bw-hwell)log((Rwr),10)
​Go Coefficient of Transmissibility given Confined Aquifer Discharge
Tenvi=Q2πstlog((Rwr),e)

How to Evaluate Coefficient of Transmissibility given Depth of Water in Two Wells?

Coefficient of Transmissibility given Depth of Water in Two Wells evaluator uses Coefficient of Transmissibility = Discharge/((2.72*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Well 1),10))) to evaluate the Coefficient of Transmissibility, The Coefficient of Transmissibility given Depth of Water in Two Wells formula is defined as the value of the coefficient of transmissibility when we have prior information of depth depth of water in two wells. Coefficient of Transmissibility is denoted by Tenvi symbol.

How to evaluate Coefficient of Transmissibility given Depth of Water in Two Wells using this online evaluator? To use this online evaluator for Coefficient of Transmissibility given Depth of Water in Two Wells, enter Discharge (Q), Depth of Water 2 (h2), Depth of Water 1 (h1), Radial Distance at Observation Well 2 (r2) & Radial Distance at Well 1 (r1') and hit the calculate button.

FAQs on Coefficient of Transmissibility given Depth of Water in Two Wells

What is the formula to find Coefficient of Transmissibility given Depth of Water in Two Wells?
The formula of Coefficient of Transmissibility given Depth of Water in Two Wells is expressed as Coefficient of Transmissibility = Discharge/((2.72*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Well 1),10))). Here is an example- 2.578636 = 1.01/((2.72*(17.8644-17.85))/(log((10/1E-09),10))).
How to calculate Coefficient of Transmissibility given Depth of Water in Two Wells?
With Discharge (Q), Depth of Water 2 (h2), Depth of Water 1 (h1), Radial Distance at Observation Well 2 (r2) & Radial Distance at Well 1 (r1') we can find Coefficient of Transmissibility given Depth of Water in Two Wells using the formula - Coefficient of Transmissibility = Discharge/((2.72*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Well 1),10))). This formula also uses Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Coefficient of Transmissibility?
Here are the different ways to Calculate Coefficient of Transmissibility-
  • Coefficient of Transmissibility=Discharge/((2.72*(Aquifer Thickness-Depth of Water in Well))/(log((Radius of Influence/Radius of Well),10)))OpenImg
  • Coefficient of Transmissibility=Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e)))OpenImg
Can the Coefficient of Transmissibility given Depth of Water in Two Wells be negative?
No, the Coefficient of Transmissibility given Depth of Water in Two Wells, measured in Kinematic Viscosity cannot be negative.
Which unit is used to measure Coefficient of Transmissibility given Depth of Water in Two Wells?
Coefficient of Transmissibility given Depth of Water in Two Wells is usually measured using the Square Meter per Second[m²/s] for Kinematic Viscosity. Square Meter per Hour[m²/s], Square Centimeter per Second[m²/s], Square Millimeter per Second[m²/s] are the few other units in which Coefficient of Transmissibility given Depth of Water in Two Wells can be measured.
Copied!